Brand:

Legrand 411761 DX3-ID 4P 63 A 30 mA Type A RCCB

Description

411761: Legrand DX3-ID 4-pole 63 A 30 mA type A RCCB, decoded

The Legrand 411761 is a DX3-ID residual current circuit breaker (RCCB) with four poles, a rated current of 63 A, a rated residual current of 30 mA and type A detection. Type A means the device responds to sinusoidal AC residual currents and to pulsating DC residual currents. The RCCB is 4 modules wide (71.2 mm), has the neutral on the right-hand side and works on 400 V AC, 50 Hz. Seven Star LLC supplies 411761 in Oman and the GCC as an independent supplier in Muscat.

An RCCB protects people and installations against earth leakage, but it does not protect against overload or short circuit. It must always be paired with an upstream or series circuit breaker or fuse, which is a point that designers and buyers often overlook when specifying residual current devices.

Decoding the description of 411761

Element Value Meaning
DX3-ID Range Legrand electromagnetic RCCB family with enhanced immunity to unwanted tripping
4P Four poles Three phases plus neutral; neutral on the right-hand side
63 A Rated current Maximum load current through the device
30 mA Rated residual current Sensitivity for additional protection of people
Type A Detection class AC and pulsating DC residual currents
Ref. 411761 Catalogue number Reference to quote

Technical specifications for 411761

Parameter Specification
Manufacturer / part number Legrand / 411761 (DX3-ID RCCB, 4P, 63 A, 30 mA, type A)
Poles / rated current 4 / 63 A
Rated residual current 30 mA, type A, not selective, no short-time delay
Rated voltage 400 V AC; nominal range 320–440 V; 50 Hz
Insulation Ui / Uimp 500 V / 4 kV
Conditional short-circuit current 10 kA with a suitable upstream short-circuit device
Surge current capacity 0.25 kA (8/20 µs wave per data sheet)
Width / height / depth 71.2 mm / 83 mm / 77.8 mm; built-in depth 44 mm
Conductors Multi-wire 0.75–35 mm²; solid-core 0.75–50 mm²
Protection IP20 (wired), IK04, pollution degree 2
Temperature Operating -25 to 60 °C; storage -40 to 70 °C
Terminals Screw terminals for busbar and cable; supply from top or bottom; terminal marking
Construction Halogen-free housing, label space, interlocking device possible
Mounting 35 mm DIN rail (EN 60715)

How the 411761 detects leakage

Inside the device a toroidal sensor encircles all four conductors. In a healthy circuit the vector sum of the currents is zero. When part of the current flows to earth, for example through a damaged cable or a person, the sum becomes non-zero and an electromagnetic relay opens the contacts. The DX3-ID is described in the data sheet as an electromagnetic residual current function with a current-sensing relay.

The data sheet states that the device is tested with 20,000 mechanical operations, 10,000 operations under load and 2,000 trips by the test button or by fault current. It is not suitable for direct current or 400 Hz, and the data sheet adds a note for 60 Hz use that excludes some 40, 63 and 80 A type A and AC versions with 30 mA sensitivity, so 411761 should be applied on 50 Hz networks.

Where 411761 fits and related parts

Fit 411761 at the head of a group of final circuits, each protected by its own MCB, such as 407929 or 409071 for four-pole feeders or smaller single-phase breakers for lighting and sockets. Several RCCBs in a board give discrimination between groups: a fault trips only the affected group. The same DX3-ID series covers 25, 40, 63, 80 and 100 A, in AC, A, AC-S and A-S types with 30, 100, 300 and 500 mA sensitivity. The 30 mA type A version here is the usual choice for socket outlets, workshops and areas where people can touch live equipment. Upstream protection should be sized so that the RCCB 63 A rating is not exceeded.

Selection checklist for 411761

  • Rated current: 63 A or more than the sum of group loads, with a series MCB no larger than 63 A.
  • Sensitivity: 30 mA for people protection; use 100 to 500 mA or selective versions for fire or discrimination.
  • Type: A covers pulsating DC; consider F or B types where inverters or drives are present.
  • Network: 400 V, 50 Hz, with neutral on the right-hand side.
  • Back-up protection: 10 kA conditional short-circuit rating needs an appropriate MCB or fuse upstream.
  • Environment: the data sheet lists operation in humid atmospheres, including chlorine-polluted pool-type areas.

Installation, testing and maintenance of 411761

Snap the device onto the rail and connect three phases and the neutral to the marked terminals. The neutral is on the right side, so connect it correctly or the device will not work. Tighten the terminals to the torque in the instruction sheet, and strip conductors to the length shown. After installation press the test button; the device should trip. Repeat the test periodically, for example every six months, and record the result alongside the reference 411761. Because the device is installed in a row, it can be replaced mid-row without disconnecting neighbouring products when the busbar is used.

Typical applications in Oman and the GCC

RCCBs with 30 mA sensitivity are common in commercial buildings, camps, workshops and utility boards in Oman and the GCC, where wet cleaning, outdoor sockets and temporary power increase earth-leakage risk. The data sheet notes suitability for humid atmospheres with chlorine, such as pool areas. In hot rooms, keep the operating temperature below 60 °C and avoid dense packing with heavily loaded neighbours.

Family table around 411761

Rating Types listed in the data sheet Sensitivities
25 A and 40 A AC, A, AC-S, A-S 30, 100, 300, 500 mA
63 A (this page, 411761) A, 30 mA version 30 mA
80 A AC, A 30, 100, 300, 500 mA
100 A A 30, 100, 300, 500 mA

Information to send with an RFQ for 411761

  • Reference 411761 and the quantity, including spares for panel maintenance.
  • Rated current, number of poles and sensitivity (30, 100, 300 or 500 mA).
  • Residual current type (AC, A, F or B) and the type of loads on the circuit.
  • Upstream breaker rating and board layout.
  • Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
  • Any documents you need with the quotation, such as a technical data sheet or a compliance statement.

Documents and quotation

The Legrand technical data sheet that covers 411761 is attached on this page. It gives the range table, dimensions, curves and accessories, so check its notes against your design before you order.

To request a quotation, send reference 411761, the quantity and your delivery location. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer; we will confirm availability and lead time for your order.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Legrand is a French maker of electrical and digital building infrastructure, headquartered in Limoges. Its roots lie in a nineteenth-century porcelain workshop in Limoges, and it grew into one of the largest makers of wiring devices, circuit protection, cable management and data centre products. Legrand is listed on Euronext Paris and sells under brands including Legrand, Bticino and Cablofil.

Seven Star LLC, an independent supplier in Muscat, lists Legrand circuit breakers for electrical contractors and panel builders in Oman and the GCC, at present a DX3 4-pole miniature circuit breaker rated C32.

Legrand company profile

Headquarters Limoges, France
Listing Euronext Paris
Brands Legrand, Bticino, Cablofil, Zucchini
Product families DX3 miniature circuit breakers and RCDs, wiring devices, cable trays, busbar trunking, UPS

Legrand DX3 circuit breakers

DX3 is the Legrand family of modular protection devices for DIN rail mounting. The item on our site is a 4-pole MCB with a C tripping curve and a 32 A rated current. Three things besides the pole count define a breaker of this kind: the curve, the rated current and the breaking capacity printed on the front. Legrand catalogs DX3 breakers in 6000 A and 10000 A versions under separate references.

Ordering Legrand breakers: what we need

Send the Legrand catalog number printed on the device, a six-digit reference, where it is legible. Otherwise give the number of poles, the curve, the rated current, the breaking capacity and the voltage. Mention any auxiliary contact or residual current add-on module fitted beside the breaker, and the board type.

Facts checked against Legrand's published corporate information, October 2026.

FAQ

Questions about the Legrand 411761 DX3-ID 4P 63 A 30 mA Type A RCCB

Answers from our engineering team on installation, compatibility and integration.

01What is 411761?
It is a Legrand DX3-ID four-pole residual current circuit breaker rated 63 A with 30 mA sensitivity and type A detection, 4 modules wide with neutral on the right.
02Does 411761 protect against overload?
No. An RCCB only detects earth leakage. It must be used with a circuit breaker or fuse upstream or in series, and the data sheet lists a 10 kA conditional short-circuit rating.
03What does type A mean on 411761?
Type A detects sinusoidal AC residual currents and pulsating DC residual currents, which makes it suitable for many loads with rectifiers. It does not cover smooth DC faults.
04What conductors does 411761 accept?
The terminals take 0.75 to 35 mm² multi-wire and 0.75 to 50 mm² solid-core copper conductors, with a recommended torque of 2.5 Nm per the data sheet.
05Can 411761 be used on DC or at 400 Hz?
No. The data sheet states that the device cannot be used with direct current or at 400 Hz. Use it on 50 Hz AC networks only.