Description

Overview

The Magnetrol B35 is the sealed-cage member of the Series 3 external cage float switches, a range intended to supply critical alarm set points in clean liquid service where a vessel code applies. A float rides inside a welded chamber, a permanent magnet follows it through a non-magnetic enclosing tube, and the magnet snaps a switch when the liquid reaches the set point. Because the chamber is sealed rather than flanged, it is the compact, lower-cost way to take a switch out to the side of a vessel.

Series 3 is built to ASME B31.1 for boilers and power plant, or to ASME B31.3 and NACE for refineries and petrochemical plant. The catalogue notes that all chamber branch and circumferential weld joints are designed for full penetration and that every chamber is hydrostatically tested at 1.5 times design pressure.

Seven Star LLC is an independent supplier serving Oman and the GCC. We can quote the B35 with the switch type, chamber material and connection details your specification calls for.

Magnetrol B35 pressure and gravity ratings

Under ASME B31.1 the Magnetrol B35 is rated 1000 psig at 100 degrees Fahrenheit, falling to 875 at 550, 805 at 750 and 783 at 800 degrees, with a minimum specific gravity of 0.69. Under ASME B31.3 it keeps 1000 psig up to 100 degrees and is listed down the temperature scale to 1000 degrees Fahrenheit at 210 psig, with a minimum specific gravity of 0.69 for material code 1 and 0.72 for material code 2.

A chrome-moly variant, B35-7, uses a P22/F22 chamber with a 347 stainless steel float for high pressure at high temperature, and stress relieving of chamber welds is available for it.

Magnetrol B35 data table

Parameter Value
Standards ASME B31.1, ASME B31.3 or NACE MR0175/MR0103 construction, certificate of conformance supplied
Process temperature Up to 1000 degrees Fahrenheit (538 degrees Celsius)
Hydrostatic test 1.5 times design pressure for all chambers
Tank connections 1, 1 1/2 or 2 inch NPT, socket weld, flanged side/side or side/bottom
Switch styles Dry contact, hermetically sealed, pneumatic bleed and non-bleed; single or multiple switches
Housing Polymer coated aluminium with various electrical approvals
Model B35 sealed cage, float actuated
B31.1 rating 1000 psig at 100 F; 875 at 550 F; 805 at 750 F; 783 at 800 F
B31.3 rating 1000, 875, 805, 795, 495 and 210 psig at 100, 550, 750, 800, 900 and 1000 F
Minimum specific gravity 0.69 (material code 1), 0.72 (code 2)
Chrome-moly option B35-7, P22/F22 chamber, 347 SS float

How Magnetrol B35 differs from other Series 3 models

Within Series 3 the B3F shares the B-series float but uses a flanged cage, while the C35 and G35 sealed cages carry lower pressure ratings of 500 and 750 psig under B31.1 with minimum gravities of 0.57 and 0.54. The V35 reaches 2116 psig, and the K35 and L35 go down to a specific gravity of 0.40 and 0.41 under B31.3. If your liquid has a specific gravity above 0.69 and pressure is up to 1000 psig, the Magnetrol B35 is the usual first choice.

Reading the rating tables correctly

Pressure ratings of external cage switches fall as temperature rises, so the figure on the first line of a table is only valid at the lowest temperature. Always read the rating at the actual design temperature of the vessel, and compare it with the design pressure with a margin. For the sealed B35, the B31.1 table lists four temperature points while the B31.3 table runs to six, ending at 1000 degrees Fahrenheit, where the allowable pressure is only 210 psig. A vessel that sees steam at 800 degrees Fahrenheit therefore has about 783 to 795 psig of allowable pressure, depending on the code, not 1000.

Minimum specific gravity is the second number to check. The float must be buoyant enough at operating temperature, and many liquids become lighter when hot. If a hydrocarbon or hot condensate is close to the limit, take the gravity at operating temperature and ask for a lower-gravity variant such as the C35 or K35 instead of forcing the B35 into service. The specific gravity limit and the interface calibration options are summarised in the catalogue, and our team can help you compare them against your process data sheet.

Applications

  • Feedwater heaters, deaerators, steam drums and flash tanks under ASME B31.1.
  • Gas and oil separators, knockout drums and flare pots under ASME B31.3.
  • Condensate drip pots and hot wells.
  • Crude and salt water separators, accumulators and receivers.
  • Sour service where NACE construction is specified.

Options to review before ordering

Series 3 offers special coatings, high or low temperature insulation, tandem floats where actuating levels are 8 inches or more apart, multiple switches, interface calibration for gravity differences as small as 0.10, and quality tests such as dye penetrant, radiography, Charpy, magnetic particle, extended hydrostatic, ultrasonic and hardness testing. Material alternatives include 304 and 316 stainless steel, Hastelloy C, Monel, Carpenter 20 and duplex stainless steel.

Tell us the vessel code, the liquid and its density at operating temperature, the set points and the connection style, and we will check the model code with you.

Installation and commissioning

Connect the chamber to the vessel with isolation valves where the specification allows, orient the switch so the float travels freely, and wire the enclosure through the 1 inch NPT entry. Cycle the level slowly during commissioning to confirm actuation points, and record them. Relieve pressure and drain before opening a chamber.

Check hazardous area certificates against the site requirement, since the aluminium enclosures carry different approvals.

Maintenance

Inspect the enclosure seals and terminals, test the alarm at shutdowns, and examine the float for deposits if the service is dirty. Magnetic particles in the liquid can cling to the float and impair motion, so clean as needed.

Related items you may also need: Magnetrol 089-7827-011 LVDT Kit, Low Temperature, for E4 Modulevel | Magnetrol Z31-2849-001 Electronic Module for Eclipse 706 GWR | Magnetrol 089-9126-001 Echotel 355 Transducer Kit, Polypropylene | All Magnetrol products.

Documents and quotation

The Magnetrol catalogue 46-123 is provided as the datasheet for the Magnetrol B35. Send your RFQ with the part number B35, the vessel code, set points and quantity, and we will respond with availability and lead time for Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet Magnetrol B35 Series 3 Sealed Cage Float Level Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.

Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.

Magnetrol company profile

Established 1932, USA; headquarters in Aurora, Illinois
Ownership Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group
Product families Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand)
Applications Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection

Milestones

  • 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
  • 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
  • 2021: AMETEK acquires Magnetrol on 29 March.

Magnetrol products we list

Model Principle Typical use
Eclipse 706 Guided wave radar Level and interface in separators, chambers and boiler drums, unaffected by changing density
Pulsar R80 80 GHz FMCW radar Narrow-beam non-contact level in tanks with internals and in solids
Pulsar R86 26 GHz radar Non-contact level in process and storage vessels
Pulsar R96 6 GHz radar Non-contact level where vapour, foam or condensation are present
E4 Modulevel Displacer Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units
Echotel 961/962 Ultrasonic gap switch High and low level alarms and pump protection
Thermatel TD1/TD2 Thermal dispersion switch Flow and no-flow detection and level switching for liquids and gases

Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.

Where Magnetrol instruments are used

In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.

Ordering Magnetrol instruments: what we need

Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.

Facts checked against Magnetrol and AMETEK company information, October 2026.

FAQ

Questions about the Magnetrol B35 Series 3 Sealed Cage Float Level

Answers from our engineering team on installation, compatibility and integration.

01What kind of switch is the Magnetrol B35?
It is a Series 3 float-actuated external cage level switch with a sealed chamber, built to ASME B31.1, B31.3 or NACE construction for critical alarm set points.
02What is the pressure rating of the Magnetrol B35?
Under ASME B31.1 it is rated 1000 psig at 100 degrees Fahrenheit, and under B31.3 it is 1000 psig at 100 degrees, reducing to 210 psig at 1000 degrees Fahrenheit.
03What is the minimum specific gravity for the Magnetrol B35?
The catalogue gives 0.69 for B31.1 and for B31.3 material code 1, and 0.72 for B31.3 material code 2.
04Is a high temperature version of the B35 available?
The B35-7 uses a P22/F22 chrome-moly chamber with a 347 stainless steel float for high pressure at high temperatures under ASME B31.1.
05What switch types can the Magnetrol B35 use?
Series 3 offers dry contact, hermetically sealed, pneumatic bleed and non-bleed switches, in single or multiple arrangements.