Description
Overview
The EUCHNER ESM-BA201 is a basic safety relay module for emergency stop circuits and guard monitoring. It takes a one-channel or two-channel signal from an emergency stop button or door switch, and in response closes two redundant, positively driven normally open contacts that can be used to cut the supply to contactors or drives. The 24 V AC/DC version described here is the entry point of the ESM-BA2 range and reaches category 4 and PL e at a low price of complexity. Seven Star LLC is an independent supplier serving Oman and the GCC.
What the code EUCHNER ESM-BA201 tells you
ESM is the family of safety relays, BA marks the basic module for emergency stop and guard monitoring, 2 stands for two safety contacts, and the final digits select the supply: 01 is 24 V AC/DC, 02 is 115 V AC and 03 is 230 V AC. The article number of this version is 085610. A letter P at the end of related codes, as in ESM-BA201P, means plug-in terminals.
Technical data of EUCHNER ESM-BA201
| Parameter | Value |
|---|---|
| Supply | 24 V AC/DC, plus or minus 10 percent, 50 to 60 Hz |
| Power consumption | about 1.5 W at 24 V DC |
| Safety contacts | 2 NO, floating and positively driven (13/14, 23/24) |
| Breaking capacity | AC 250 V, 1500 VA, 6 A ohmic; DC 24 V, 144 W, 6 A ohmic |
| Utilization | 250 V 3 A AC-15; 24 V 3 A DC-13 |
| Minimum contact load | 5 V, 10 mA |
| Contact fuse | 10 A gG |
| Delay times | switch-on under 50 ms, switch-off under 20 ms |
| Control line | up to 1000 m with 0.75 square mm |
| Control voltage / current | 24 V DC at S11, about 40 mA |
| Contact material | AgSnO2; mechanical life about 10 million cycles |
| Insulation / impulse / test voltage | 250 V / 4 kV / 2.5 kV |
| Protection | IP20, mounted on TH35 rail, weight about 230 g |
| Temperature | minus 15 to plus 60 degrees C on DC 24 V |
| Safety data | Category 4, PL e, PFH 1.2 x 10 to the minus 8, T10D 20 years |
How EUCHNER ESM-BA201 differs from other ESM-BA modules
The ESM-BA202 and ESM-BA203 offer the same relay output for supplies of 115 V AC and 230 V AC. The ESM-BA201P is the 24 V version with plug-in connection terminals for quick exchange. The ESM-BA301 grows to three safety contacts and adds one auxiliary contact, so it is selected when more loads must be switched off or a status message is required. The EUCHNER ESM-BA201 stays with two safety contacts and no auxiliary contact, which keeps the module narrow at only a few centimetres on the rail.
Functions that matter in practice
The module monitors short circuits and earth faults in the control line, accepts one-channel or two-channel control and can start in two ways. With automatic start the contacts close as soon as the emergency stop circuit is closed. With monitored manual start, a start button must be pressed and released, which prevents a stuck button from restarting the machine. Two green LEDs show the state of the internal relays K1 and K2.
Typical uses in the Gulf
These modules are found in control panels for pump stations, compressors, conveyors, packing machinery, gates and small process plants. The 24 V AC/DC input matches the standard control voltage of PLC cabinets, and the two contacts are often wired in series with the coils of two contactors. The relay is mounted in a cabinet of at least IP54 as the module itself is IP20.
Wiring and set-up
Connect the supply to A1 and A2, the emergency stop contacts to the control inputs and the start circuit as shown in the manual to select automatic or monitored manual start. Check the start button is open before closing the emergency stop circuit when monitored start is used. Load contacts must be fused at 10 A gG, and the load should include suppression if it is inductive. Conductors may be 0.14 to 2.5 square mm and the terminals should be tightened to 0.5 to 0.6 Nm.
Choosing between one-channel and two-channel control
The EUCHNER ESM-BA201 accepts either a one-channel or a two-channel emergency stop circuit. One-channel wiring is simple and reaches only lower categories according to the wiring examples in the manual, and a single wire fault could go unnoticed between operations. Two-channel wiring with short circuit and earth fault monitoring lifts the architecture to category 4 and PL e, and it is the recommended choice for new machines. The control line can be as long as 1000 m with a cross-section of 0.75 square mm, which covers most plant layouts, but the cable should be kept away from power cables to avoid induced voltages.
Contact life depends on the load. At 0.1 A in DC-13 the manufacturer allows up to 400,000 cycles, at 1 A up to 100,000, and at 3 A up to 22,500 cycles. For applications with frequent emergency stop operation or high inrush, an external contactor is a better way to keep contact wear low than loading the relay contacts to the limit.
Extending the number of contacts
If a machine needs more than two safety contacts, the output can be multiplied by contactors with positively guided contacts, or by an expansion module from the same range, while keeping the feedback loop closed through the contactor auxiliary contacts. Keep the wiring of the loop short and verify, during every test, that the machine cannot restart when a contactor is welded. This behaviour is one reason the module is accepted for category 4 circuits.
Testing and service
Test the module after commissioning and at regular intervals by operating the emergency stop and observing that both contacts open. Keep the supply within its tolerance, and check that the cabinet temperature does not exceed the limit. Because the relay is subject to wear, record the number of operations on busy applications, in line with the stated load-dependent cycles of up to 400,000 at 0.1 A, 100,000 at 1 A and 22,500 at 3 A.
Ordering notes
Quote the exact code, because the supply voltage is part of the order code. Add an emergency stop device or door switch if required. Seven Star LLC can supply the module with companion safety switches.
Related items you may also need: EUCHNER ESM-TE301 Time-Delayed Safety Contact Expansion | EUCHNER MSC-CB-AC-FI8FO2 Modular Safety Controller Base Unit | EUCHNER MGB2-H-BA1A3-R Handle Module | All EUCHNER products.
Documents and quotation
The operating instructions for the ESM-BA2 basic modules are attached to this page. Send your RFQ with EUCHNER ESM-BA201, the quantity and the delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet EUCHNER ESM-BA201 Emergency Stop Safety Relay 24 V Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.
Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.
EUCHNER company profile
| Origins | 1940, engineering office of Emil Euchner near Stuttgart, Germany |
|---|---|
| Company founded | 1953, as EUCHNER + Co. |
| Headquarters | Leinfelden-Echterdingen, Baden-Württemberg, Germany |
| Ownership | Family-owned |
| Product families | Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems |
Milestones
- 1940: Emil Euchner sets up an engineering office.
- 1952: He develops the first multiple limit switch.
- 1953: EUCHNER + Co. is founded.
EUCHNER product series
Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.
Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.
Where EUCHNER components are used
Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.
EUCHNER products we list
Ordering EUCHNER components: what we need
Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.
Facts checked against EUCHNER's published company history, October 2026.
Browse EUCHNER products by category: Safety Switches & Guard Locking.
FAQ
Questions about the EUCHNER ESM-BA201 Emergency Stop Safety Relay 24 V
Answers from our engineering team on installation, compatibility and integration.
01What supply does the EUCHNER ESM-BA201 need?
It is the 24 V AC/DC version, with a tolerance of plus or minus 10 percent at 50 to 60 Hz and a power consumption of about 1.5 W at 24 V DC.
02How many safety contacts does the EUCHNER ESM-BA201 have?
It has two floating, positively driven normally open safety contacts, 13/14 and 23/24, and no auxiliary contact.
03What safety rating does the ESM-BA201 achieve?
The manufacturer states Category 4 and PL e with a PFH of 1.2 x 10 to the minus 8 and a T10D of 20 years.
04What start modes are possible with the ESM-BA201?
It supports automatic start and monitored manual start, selected by the way the start circuit is wired.
05How does the ESM-BA201 differ from the ESM-BA301?
The BA301 has three safety contacts and one auxiliary contact, while the BA201 has two safety contacts only.