If a machine builder wants one safety switch that accepts any suitable actuator and still reaches category 4, the EUCHNER CES-A-W5H-01 is the usual pick. It is a rectangular transponder-coded switch with built-in evaluation, an 8-pin M12 connection and two redundant semiconductor safety outputs. Where its sibling the CES-A-C5E-01 learns a single actuator, this multicode version recognises every compatible actuator, which keeps commissioning and replacement simple. Seven Star LLC is an independent supplier serving Oman and the GCC.

Reading the code EUCHNER CES-A-W5H-01

CES-A is the series. W5 means the housing with multicode evaluation, H is the category 4 version and 01 describes the cable connection arrangement. The article number is 097525. Actuators are ordered separately; the series data mention CES-A-BBA-071840, CES-A-BCA and CES-A-BDA-20 among those that may be used.

Technical data table for EUCHNER CES-A-W5H-01

Item Data
Evaluation Multicode, every suitable actuator is detected
Rating Category 4, PL e, PFH 3.7 x 10 to the minus 9
Outputs Two safety outputs LA/LB plus monitoring output OUT
Switching current per safety output 1 to 400 mA, DC-13 at 24 V
Supply 18 to 27 V DC, 80 mA
Response time up to 180 ms
Discrepancy time up to 120 ms
Ready delay up to 3 s
Repeat accuracy 10 percent
Size 131 x 40 x 40 mm, PBT housing
Protection IP65 / IP67
Ambient range minus 20 to plus 55 degrees C
Mounting distance between switches at least 80 mm
Actuator distances with CES-A-BBA-071840 switch-on 20 mm, safe switch-off 40 mm, safe switching min. 18 mm

How EUCHNER CES-A-W5H-01 differs from other CES-A types

Three neighbours help to place this switch. The CES-A-C5E-01 is a unicode design in category 3. The CES-A-C5H-01 is unicode in category 4, and the CES-A-C5H-01-EX is the same with ATEX protection for zones 2 and 22. The EUCHNER CES-A-W5H-01 is the only one of the four standard codes that is multicode. In numbers, its PFH is 3.7 x 10 to the minus 9 against 4.29 x 10 to the minus 8 for the category 3 unicode switch, and the minimum side distance for the BBA actuator is 3 mm.

When multicode is the right choice

Multicode evaluation is best when tampering is not the main concern but flexibility is: machines with several identical doors, swap-in tools, or service departments that hold a stock of interchangeable actuators. Since any approved actuator will work, a broken actuator can be replaced immediately without a teach-in step. Where the risk assessment demands protection against defeat, choose unicode instead, or add organisational measures.

Fields of use around the Gulf

Because it has no mechanical wear, the EUCHNER CES-A-W5H-01 is well suited to packaging and filling machinery, material handling, wastewater screening equipment, test cells and enclosed robotics. The compact PBT body can be mounted on aluminium profiles with simple brackets, and the IP67 rating tolerates wash-down. For cabinets exposed to the sun, remember the ambient limit of 55 degrees C.

Mounting and distances

With the actuator CES-A-BBA-071840 or CES-A-BCA the typical switch-on distance is 20 mm for surface mounting, the safe switch-off distance is 40 mm and the safe switching distance with no lateral offset is at least 18 mm. When the actuator moves sideways past the switch, keep a gap of at least 3 mm. Space switches 80 mm apart to prevent mutual influence, and fit the actuator so that it dwells in or outside the range for at least 0.5 s.

Electrical connection and start-up

Use a regulated 18 to 27 V DC supply with an external fuse between 0.25 and 8 A, and a 0.4 A medium slow-blow fuse for the safety circuit. Both outputs have to be read by the safety logic. At power-up the safety outputs stay off for up to 3 s. For UL installations the supply must be a Class 2 type or equivalent.

Validation and safety calculations

For the EUCHNER CES-A-W5H-01 the manufacturer gives Category 4 and PL e, a PFH of 3.7 x 10 to the minus 9 per hour and a mission time of 20 years for monitoring the position of a guard. In a typical calculation, these values are combined with the figures for the safety relay or controller and the output contactors, and the result is compared with the required performance level of the machine. The two semiconductor outputs are electrically separated, p-switching and short-circuit proof, so the switch can be connected straight to the inputs of a safety PLC. Only one monitoring output exists and it is non-safe; use it for diagnostics only.

Remember that the value is valid only if the stated conditions are respected: regulated supply, the specified fuses, the ambient range and correct installation. Record the actuator part number used in the validation so that later replacement does not change the safety distances.

Diagnosis when the outputs stay off

Begin with the supply voltage and wait at least the ready delay of 3 s after switching on. Check that the actuator type matches the one used in the validation, that it lies inside the operating range and that no steel plate shifts the field. Examine the M12 plug for bent pins or water, and the cable for damaged insulation. The diagnostic LED shows combined output status and error state, and the operating instructions list the flash codes for faults such as short circuits, discrepancy errors or a supply that is too low. If the fault persists, replace the actuator before replacing the switch, since a damaged actuator is a common cause.

Maintenance routine

Wipe the active face, look for loose fixings and cable damage, and confirm that the diagnostic LED shows the expected state. Re-check the alignment after any machine modification and after the door has been struck.

Ordering information

State the complete code and the actuator type. Actuators are not part of the switch, and an M12 8-pin cable may also be needed. Quote the existing nameplate if the switch replaces another type.

Related items you may also need: EUCHNER CES-AP-CL2-AH-SB-111747 RFID Safety Switch, M12 | EUCHNER TZ1RE024SR11 Guard Locking Safety Switch, 24 V | EUCHNER ZSB054784 Three-Stage Enabling Switch with +/- Buttons | All EUCHNER products.

Documents and quotation

The operating instructions for the non-contact CES-A switch series are attached to this page. Send your RFQ with EUCHNER CES-A-W5H-01, the quantity and the delivery destination in Oman or the GCC.

Other Models in the Cesa Range

Seven Star LLC supplies models from the Cesa range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
EUCHNER CES-A-C5E-01 Non-Contact Unicode Safety SwitchSafety Switches & Guard LockingView details
EUCHNER CES-A-W5H-01 Multicode Non-Contact Safety SwitchSafety Switches & Guard LockingYou are viewing this model
Datasheets & Documents
  • PDF Datasheet EUCHNER CES-A-W5H-01 Multicode Non-Contact Safety Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.

Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.

EUCHNER company profile

Origins 1940, engineering office of Emil Euchner near Stuttgart, Germany
Company founded 1953, as EUCHNER + Co.
Headquarters Leinfelden-Echterdingen, Baden-Württemberg, Germany
Ownership Family-owned
Product families Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems

Milestones

  • 1940: Emil Euchner sets up an engineering office.
  • 1952: He develops the first multiple limit switch.
  • 1953: EUCHNER + Co. is founded.

EUCHNER product series

Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.

Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.

Where EUCHNER components are used

Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.

EUCHNER products we list

Family Examples
Safety Switches & Guard Locking CES-IA-BR-U-C07-SA Non-Contact Safety Switch, CTA-L1-BP-U-HA-AP-SA Guard Locking Safety, CTM-LBI-BP-U-AZ-SA BiState Guard Locking, CTP-I-AP-U-HA-ZZ-SA Safety Switch without, CTP-L1-BP-U-HA-AZ-SA Guard Locking Safety, CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety, ESM-BA301 Safety Relay, ESM-BT411 Safety Relay with Time-Delayed and 9 more

Ordering EUCHNER components: what we need

Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.

Facts checked against EUCHNER's published company history, October 2026.

FAQ

Questions about the EUCHNER CES-A-W5H-01 Multicode Non-Contact Safety

Answers from our engineering team on installation, compatibility and integration.

01What does multicode mean for the EUCHNER CES-A-W5H-01?
Every suitable actuator is detected by the evaluation, so a replacement actuator can be used without a teach-in procedure.
02Which safety category does the EUCHNER CES-A-W5H-01 reach?
It is Category 4 and PL e according to EN ISO 13849-1, with a PFH of 3.7 x 10 to the minus 9 and a mission time of 20 years.
03What are the switching distances of the CES-A-W5H-01 with CES-A-BBA-071840?
The manufacturer lists a switch-on distance of 20 mm, a safe switch-off distance of 40 mm and a safe switching distance of at least 18 mm.
04What is the supply of the CES-A-W5H-01?
It needs 18 to 27 V DC regulated, draws 80 mA and has an 8-pin M12 connection with two safety outputs and one monitoring output.
05How does the CES-A-W5H-01 differ from the CES-A-C5H-01?
Both are Category 4, but the W5H detects every suitable actuator, while the C5H is unicode and detects only taught-in actuators.