Brand: Bürkert
Bürkert 436475 Type 8032 SE32 Relay Flow Threshold Detector
Description
Overview
Not every flow switch should drive electronics: sometimes a dry relay contact is needed for a starter coil or a mains-voltage alarm. Bürkert 436475 is the Bürkert Type 8032 SE32 threshold detector with a relay output, supplied with a free positionable 5-pin M12 male connector. The same paddle wheel, display and teach-in are present as in the transistor versions. Seven Star LLC is an independent supplier serving Oman and the GCC.
Relay data of Bürkert 436475
| Parameter | Value |
|---|---|
| Article | 436475, SE32 threshold detector, relay, no UL |
| Relay rating, non UL, single relay | 250 V AC / 3 A or 30 V DC / 3 A |
| Operation | thresholds parameterised: hysteresis or window |
| Electrical connection | Free positionable 5-pin M12 male connector |
| UL approval | No (UL Recognized version is 570476) |
| Principle | Paddle wheel with 8-digit backlit LCD |
| Supply | 12 to 36 V DC plus or minus 10 percent, SELV and LPS, reverse-polarity protected |
| Current consumption | 80 mA or less with no load |
| Flow range | 0.5 to 1000 l/min, 0.3 to 10 m/s with Type S030 fitting |
| Deviation | teach-in plus or minus 1 percent; standard K factor plus or minus 3 percent |
| Linearity and repeatability | 0.5 percent of full scale; 0.4 percent of reading |
| Operating mode | threshold with window or hysteresis |
| Pipe size | DN 06 to DN 65 |
| Viscosity and solids | 300 cSt max.; up to 1 percent solids, 0.5 mm |
| Fluid temperature with S030 | PVC 0 to 50; PP 0 to 80; PVDF, steel or brass minus 15 to plus 100 degrees C |
| Fluid pressure | plastic PN 10, metal PN 16 |
| Housing | glass fibre reinforced PC, polyester front film |
What the relay changes in Bürkert 436475
A relay isolates the switching circuit from the 12 to 36 V DC supply, and allows switching of loads up to 250 V AC at 3 A on the non-UL device, so a small pump contactor or alarm horn can be driven directly. The UL version is rated lower, at 30 V AC or 60 V DC at the stated currents, and has a different number. Mechanical contacts wear with switching cycles and with inductive loads, so use a suppressor on coils and avoid using the relay for fast pulsing.
How Bürkert 436475 differs from other SE32 threshold articles
Transistor versions 434871, 436473 and 436474 switch up to 700 mA of low-voltage DC and can reach 300 Hz, which is far beyond what a relay can do. In exchange, 436475 switches mains-level voltages and keeps the switched circuit isolated. Compared with the transmitter 560402, which combines a relay with a 4 to 20 mA output, it carries the relay only and uses the M12 connector without the extra cable plug.
Straight pipe, orientation and flow profile
A paddle wheel responds to local velocity, so a disturbed profile changes the reading. Keep a straight inlet of about ten diameters and an outlet of about five, fit the sensor where the pipe is always full, and avoid installing it in a vertical down-flow line that may drain. Entrained air gives unstable readings, and so do solids above 1 percent by volume or particles above 0.5 mm. If the liquid is viscous, remember the 300 cSt ceiling. A strainer upstream helps protect the wheel in raw water service.
Interlock and protection use
A typical use is a flow interlock on a lube oil or cooling circuit: the relay closes when flow exceeds the minimum, allowing the machine to start. Wire the relay in series with the permissive chain and add a delay in the PLC to ride through short flow dips at start-up.
Relay wiring for Bürkert 436475
The relay output is a dry contact that switches an external supply. Wire it in series with the circuit it controls: for example, in the control circuit of a motor starter, the contact closes when flow exceeds the threshold. For inductive loads such as contactor coils, fit a suppressor across the load to protect the contact. Keep within the 3 A rating and limit the switching frequency, since mechanical contacts wear with every switch. The relay and the supply circuit are isolated from each other, which helps in mixed-voltage panels.
Do not exceed the rating of 250 V AC at 3 A on the non-UL device, and note that devices with a 4 to 20 mA output together with the relay have a lower relay rating of 48 V AC.
Quotation notes for Bürkert 436475
Please give the article number, the number of units, the pipe size and fitting material, and the M12 connector needs. The female connector is not included. State the voltage and current of the circuit that the relay will switch so that the suitability of the contact rating can be confirmed. Delivery to Oman and the GCC will be planned from the details.
Typical interlock circuits
In lubrication and cooling circuits, the flow switch gives a permissive for starting a machine. In dosing systems it confirms water flow before a chemical pump starts. In heating systems it proves flow before a burner or heater is released, which protects the heat exchanger.
Delivery notes for Bürkert 436475
The device is delivered with the M12 male connector fitted; the female connector and the Inline fitting are separate. The data sheet attached to this page gives dimensions, relay ratings and the pin assignment. If your project needs a UL version, state it in your enquiry, since the UL Recognized equivalent has its own article number and a different relay rating.
Why a relay can be better than a transistor
Transistor outputs are fast and silent, but they switch only low-voltage DC and need the right polarity. A relay isolates the contacts and handles both AC and DC loads up to its rating, so it can replace an interposing relay in the panel. In exchange it is slower, has a limited number of operations and cannot be used for frequency output. For simple permissive and alarm duties, a few switches per hour, the relay is more than adequate and often simpler to integrate.
Related items you may also need: Bürkert Type 8681 Control Head for Hygienic Process Valves | Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | KRACHT VC 0.01 Micro Gear Type Flow Meter | All Bürkert products.
Documents and quotation
The Type 8032 data sheet containing Bürkert 436475 is attached with ordering charts and dimension drawings. Send an RFQ with part number 436475, quantity and delivery location in Oman or the GCC, and mention pipe size and material for the Inline fitting.
Other Models in the 8032 Range
Seven Star LLC supplies models from the 8032 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Bürkert 434871 Type 8032 SE32 PNP Flow Threshold Detector | Turbine & Positive Displacement Flowmeters | View details |
| Bürkert 436473 Type 8032 SE32 Dual Output Flow Detector | Turbine & Positive Displacement Flowmeters | View details |
| Bürkert 560403 Type 8032 SE32 4-20 mA Flow Transmitter | Turbine & Positive Displacement Flowmeters | View details |
| Bürkert 436475 Type 8032 SE32 Relay Flow Threshold Detector | Turbine & Positive Displacement Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet Bürkert 436475 Type 8032 SE32 Relay Flow Threshold Detector Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.
Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.
Bürkert company profile
| Founded | 1946, by Christian Bürkert |
|---|---|
| Headquarters | Ingelfingen, Germany |
| Ownership | Family-owned |
| Product families | Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers |
Bürkert types listed on this page
Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.
Ordering Bürkert valves: what we need
The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.
Facts checked against Bürkert's published company history, October 2026.
Browse Bürkert products by category: Solenoid Valve, Control Valves.
FAQ
Questions about the Bürkert 436475 Type 8032 SE32 Relay Flow Threshold
Answers from our engineering team on installation, compatibility and integration.
01What output has Bürkert 436475?
It has a relay output with parameterised thresholds; the non-UL device is rated 250 V AC at 3 A or 30 V DC at 3 A for a single relay.
02What connector does 436475 use?
It has a free positionable 5-pin M12 male connector, and the female connector must be ordered separately.
03Is Bürkert 436475 UL approved?
No. The UL Recognized equivalent has article number 570476 and uses a lower relay rating.
04Can 436475 work as a flow window switch?
Yes. The threshold operation can be set as hysteresis or window on the module.
05What pipe sizes does 436475 cover?
With the Inline sensor-fitting Type S030 it covers pipes from DN 06 to DN 65.