MICHELL Instruments S4000 TRS Precision Dew-Point Hygrometer

Description

Overview

Calibration laboratories need a dew-point reference they can defend to an auditor, and the MICHELL Instruments S4000 TRS is built for exactly that. It is a precision chilled mirror hygrometer that measures minus 100 to plus 20 degrees Celsius dew point with accuracy of plus or minus 0.1 C, using a three-stage Peltier heat pump and internal refrigeration for auxiliary cooling. It ships, as standard, with a UKAS certificate giving traceability to the UK national standard and a path to the NIST national humidity standard. Seven Star LLC is an independent supplier serving Oman and the GCC.

What distinguishes the MICHELL Instruments S4000 TRS

  • Dual optics detection with a wide band red LED and dual photo sensors greatly increases sensitivity at low frost points, where frost forms slowly.
  • Automatic Balance Compensation (ABC) periodically drives off condensation to rebalance the optical loop and warns visibly when contamination is high.
  • A data hold function keeps the outputs steady during an ABC cycle, so the instrument can also serve in process control.
  • A 100 ohm four-wire platinum resistance thermometer measures mirror temperature, and an M4K viewing microscope is supplied to confirm water or ice on the mirror.
  • Optional VCR couplings give clean trace moisture sampling.

MICHELL Instruments S4000 TRS technical specifications

Technology Chilled mirror
Range -100 to +20 C (-148 to +68 F) dew point
Accuracy Plus or minus 0.1 C dew point; plus or minus 0.1 C temperature
Sensitivity / repeatability 0.01 C / better than 0.1 C
Resolution 0.01 (0.1 for percent RH)
Response speed 0.5 C per second plus settling time
Units C dp, F dp, C, F, percent RH, ppmV, ppmW, g/m3, g/kg, ppmW for SF6
Mirror / temperature sensing Gold plated copper; 4-wire Pt100, 1/10 DIN class B
Sample flow 0.1 to 0.7 Nl/min recommended; integral flowmeter 0 to 1 Nl/min
Sensor pressure Atmospheric
Auxiliary cooling Internal refrigeration
Analog outputs 2 channels, 10 mV per C dew point or 4-20 mA
Digital RS232
Auxiliary input Optional 4-20 mA pressure transducer, 0 to 0.34 MPa (0 to 50 psia)
Operating temperature 0 to +40 C
Power Monitor 90 to 265 V AC 50-60 Hz; sensor 100-115 or 220-240 V AC 50-60 Hz
Dimensions / weight 560 W x 600 D x 860 mm mini rack; 85 kg (187.39 lb)

Chilled mirror principle

An LED beam focused on the mirror falls in reflected intensity as condensate scatters it. Two photo-detectors measure reflected and scattered light and compare them with a reference detector watching the LED, and the resulting signals drive a thermoelectric cooler to hold condensation in equilibrium. At equilibrium the platinum thermometer reading equals the dew point. Because condensation temperature is measured directly, the datasheet notes the principle has no drift and is inherently repeatable.

Low frost points and the MICHELL Instruments S4000 TRS dual optics

At low frost points the rate of frost formation on a mirror is extremely slow. Single-optic chilled mirror meters can then show reduced accuracy, poor control stability and very long response times. The dual optics system of this instrument raises the sensitivity of the optical loop, and the datasheet states that response, stability and sensitivity improve by orders of magnitude at low frost points. This is why the model is chosen for trace moisture work in industrial gases and battery dry rooms.

Calibration integrity and traceability

The S4000 TRS is described as the only dew-point hygrometer delivered, as standard, with a full UKAS certificate. UKAS is the United Kingdom member of European co-operation for Accreditation, ILAC and IAF, and the certificate gives formal traceability to the UK national standard, with an additional path to the NIST national humidity standard in the United States. The datasheet adds that the instrument is used by many of these national organisations within their own humidity referencing systems. For a laboratory that must issue its own certificates, that chain of traceability is the main reason to specify this model.

Applications in Oman and the GCC

The datasheet lists standards laboratory reference duty, research and development, battery manufacture and industrial gases. Gulf calibration houses, university laboratories and industrial gas producers can use the S4000 TRS to certify dew-point and humidity sensors and to validate other hygrometers at very low moisture levels.

How S4000 TRS differs from the S8000 range and Optidew

  • S4000 TRS measures -100 to +20 C dew point at atmospheric sensor pressure with plus or minus 0.1 C accuracy; S8000 HT measures -30 to +95 C and S8000 -100 variants cover other ranges.
  • It uses dual optics and internal refrigeration in an 85 kg mini rack, versus the 19 inch 4U box of the S8000 HT at 22 kg.
  • S4000 TRS ships with a full UKAS certificate as standard.

Installation and care

Place the instrument in a laboratory at 0 to +40 C, connect sample at 0.1 to 0.7 Nl/min, and use VCR couplings if trace moisture is the goal. Clean the optical system only with distilled water or a high-purity solvent such as acetone, and adjust ABC cycle time, duration and recovery time to the application. Keep the viewing microscope for periodic visual verification.

Related products and ordering notes

For a quotation on S4000 TRS, state the voltage (100-115 or 220-240 V), whether VCR couplings and the pressure transducer input are required, and whether a UKAS recalibration will be needed later.

Related items you may also need: Michell QMA401 Trace Moisture Analyzer | Michell QMA-SMG-5P Replacement Medium Range Moisture Generator | Michell Instruments Easidew EA2 Dew Point Transmitter | All MICHELL Instruments products.

For the MICHELL Instruments S4000 TRS, keep the downloaded document together with your purchase order and commissioning records. Having the manufacturer reference available at installation time simplifies acceptance checks, supports later spare-part planning and gives maintenance staff a single place to confirm wiring, mounting and setup information.

Configuring the MICHELL Instruments S4000 TRS for your process

The MICHELL Instruments S4000 TRS is a model family that Michell builds to a configuration, so the orderable unit is fixed by the options below and not by the model name alone.

  • Measuring range and the gas or sample the MICHELL Instruments S4000 TRS will analyse.
  • Output signals and communication needed by your control system, for example 4-20 mA, relays or a digital protocol.
  • Supply voltage and the mounting style required on site.
  • Hazardous area classification of the installation location, if any.
  • Sample handling and process connection details, including pressure, temperature and any sampling system or accessories.

Send these details, or the full code from the nameplate of an existing unit, and the quotation will confirm the exact configuration before order.

Documents and quotation

The datasheet for the S4000 TRS is attached on this page. To check availability, send an RFQ to Seven Star LLC with the part number S4000 TRS, the quantity and your destination in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet MICHELL Instruments S4000 TRS Precision Dew-Point Hygrometer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).

Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.

MICHELL Instruments company profile

Founded 1974, Cambridge, England, by Andrew Michell
Headquarters Ely, Cambridgeshire, United Kingdom, since 2007
Ownership Process Sensing Technologies (PST)
Technology Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell)
Product families Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers

Milestones

  • 1974: Andrew Michell founds Michell Instruments in Cambridge.
  • 2007: The company moves to Ely, Cambridgeshire.
  • 2024: Michell marks 50 years, now as part of PST.

Michell product families on this page

The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.

Where Michell analyzers are used

Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.

MICHELL Instruments products we list

Family Examples
Gas Analyzer Systems Easidew PRO I.S. Intrinsically Safe Mois…, Michell CD2-WDC-002 Water Dew-Point Sens…, Michell Condumax II Hydrocarbon Dew-Poin…, Easidew EA2 Dew Point Transmitter, Michell OptiPEAK TDL600 Moisture in Natu…, Michell Promet EExd Process Moisture Ana…, Michell S8000 Precision Chilled Mirror H…
Gas Analyzer Accessories MICHELL CD2-SX-WDC-002 Water Dew-Point S…, Michell Ceramic Impedance Moisture Senso…, Michell Condumax II CD2-SCR-002 Hydrocar…

Ordering Michell parts: what we need

For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.

Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.

FAQ

Questions about the MICHELL Instruments S4000 TRS Precision Dew-Point

Answers from our engineering team on installation, compatibility and integration.

01What range and accuracy does the S4000 TRS have?
It measures -100 to +20 C dew point with accuracy of plus or minus 0.1 C, sensitivity of 0.01 C and repeatability better than 0.1 C.
02What is ABC on the S4000 TRS?
Automatic Balance Compensation periodically drives off condensation so the optical loop can be rebalanced, and it alarms visibly when contamination is too high.
03What traceability comes with the S4000 TRS?
It is delivered as standard with a full UKAS certificate giving traceability to the UK national standard, plus a direct traceability path to NIST.
04What outputs does the S4000 TRS provide?
It has two analog channels of 10 mV per C dew point or 4-20 mA, an RS232 digital port, and logic outputs for data hold, ABC status and optics alarm.
05What sample flow does the S4000 TRS need?
The recommended sample flow is 0.1 to 0.7 Nl/min, and an integral flowmeter reads 0 to 1 Nl/min with the sensor at atmospheric pressure.