Brand: KRACHT
KRACHT VC 1 K1F1P5E512 Gear Flow Meter
Description
KRACHT VC 1 K1F1P5E512 overview
KRACHT VC 1 K1F1P5E512 is a KRACHT VC gear type flow meter of nominal size 1: two meshing gears turn as oil passes through, each tooth chamber holds 1.036 cm3, and magnetic sensors count the passing teeth to produce a pulse train that is proportional to volume.
With four-fold evaluation both channels give 141 204 pulse/l, and the highest pulse frequency is 47 067 Hz, so the counter or PLC input must be fast enough.
The unit operates on the displacement principle and is therefore independent of flow profile and nearly independent of viscosity, which makes it a good fit for hydraulic oil, lube oil, diesel, glue, resin and further media up to 2 500 000 mm2/s.
Typical accuracy is plus or minus 0.3 percent of the measured value with repeatability of plus or minus 0.05 percent under steady conditions, backed by test results traceable to the German accreditation body DAkkS.
Key features of VC 1 K1F1P5E512
- FKM sealing with the encoder electronics: medium temperature -15 to 80 degrees C
- Bearing and material specification K1: ball bearing (code K), specification K1
- Encoder resolution of 35 301 with 4-fold evaluation of 141 204
- Pulsation-free measurement, any mounting position and any flow direction
- Sound level up to 70 dB(A) and weight 5.4 kg (encoder version, spheroidal cast iron)
- Measuring range 0.4 to 80 l/min and starting point 0.02 l/min
VC 1 K1F1P5E512 technical specifications
| Parameter | VC 1 K1F1P5E512 |
|---|---|
| Geometric tooth volume | 1.036 cm3 |
| Permissible particle size | 20 micrometres |
| Order code | VC 1 K1F1P5E512 |
| Highest pressure | 480 bar |
| Sensors / electronics | encoder (sensor technology 5, electronics E) with 512 pulse per revolution and M12x1 4-pole connection |
| Measuring range | 0.4 to 80 l/min |
| Sealing | FKM (code F) |
| Connection | plate mounting (P) onto a connection plate |
| Viscosity | up to 2 500 000 mm2/s |
| Resolution (standard evaluation) | 35 301 pulse/l |
| Accuracy | up to plus/minus 0.3 percent of reading (DAkkS-traceable); repeatability plus/minus 0.05 percent |
| Medium temperature (this combination) | -15 to 80 degrees C (FKM sealing) |
| Housing / gears | housing spheroidal cast iron GJS-400-15, gears steel 1.7131 |
| Starting point | 0.02 l/min |
Reading the type key of VC 1 K1F1P5E512
| Position | Code and meaning |
|---|---|
| VC | gear type flow meter |
| 1 | nominal size 1 (tooth volume 1.036 cm3) |
| K | ball bearing |
| 1 | housing spheroidal cast iron GJS-400, steel gears |
| F | FKM sealing |
| 1 | coated surface |
| P | plate mounting |
| 5 | encoder |
| E | encoder |
| 512 | encoder 512 pulse/rev with M12x1 4-pole connection |
Sensor technology 5 means encoder; the datasheet offers it only on nominal sizes 0.04, 0.2 and 1, and only on K1 and G1 specifications.
The final code 512 names the encoder with 512 pulse per revolution; the 2 500 pulse alternative is a different order code.
How VC 1 K1F1P5E512 differs from further VC variants
VC nominal sizes run 0.025, 0.04, 0.1, 0.2, 0.4, 1, 3, 5, 12, 16. VC 1 K1F1P5E512 is size 1 with 1.036 cm3 tooth volume and a resolution of 965.25 pulse/l.
Relative to the next smaller size 0.4 (0.400 cm3, 2 500.00 pulse/l) this instrument has 0.636 cm3 more per tooth chamber, and its starting point increases from 0.01 to 0.02 l/min.
Against the next larger size 3 (3.000 cm3, 333.33 pulse/l) it provides finer resolution: 965.25 versus 333.33 pulse/l, and starts to count at 0.02 rather than 0.03 l/min.
Against the standard two-sensor VC 1 K1F1P2SH (965.25 pulse/l, 5.2 kg), the encoder version raises resolution from 965.25 to 35 301 pulse/l, adds 0.2 kg (5.4 kg) and replaces the Hirschmann socket by an M12 encoder connector. The 2500 pulse/rev alternative yields 172 366 pulse/l.
Typical applications of VC 1 K1F1P5E512 in Oman and the GCC
Hydraulic and lubrication circuits on Omani oil and gas, power and water-treatment sites need to know how much oil a pump or cylinder transfers; VC 1 K1F1P5E512 counts every tooth of liquid at 0.4 to 80 l/min.
Oil filling and metering stations use the pulse output to batch a set volume; at 1.036 cm3 per tooth chamber each tooth-pass is a tiny portion of the batch.
Dosing and filling stations that must resolve very small volume increments, and test benches that need volume per degree of shaft rotation, are the typical encoder uses.
Fuel consumption measurement on diesel engines and generator sets is another listed use; VC 1 K1F1P5E512 can be wired as a pulse source to a flow computer or PLC counter.
Selection and compatibility notes for VC 1 K1F1P5E512
Flow range: keep the real flow between the lower limit and upper limit of 0.4 to 80 l/min; below the lower figure the pulse accuracy degrades, above the upper figure the pressure loss grows towards the 16 bar permissible limit.
Select the sealing material from the temperature table: this combination uses FKM, which together with the electronics yields -15 to 80 degrees C (FKM sealing).
Pipework: plate mounting (P) onto a connection plate
Filter the liquid: the permissible particle size for this specification is 20 micrometres, and a protective filter ahead of the unit is advised.
Installation, commissioning and maintenance of VC 1 K1F1P5E512
Fit VC 1 K1F1P5E512 in any position and flow direction; the unit calls for no inlet or outlet straight run, so it suits space-saving skids.
Flush the pipework before installation so that particles larger than 20 micrometres do not reach the gears.
Commission by running at a known flow and comparing the counted volume with a reference; a calibration with a measurement accuracy characteristic can be requested from the manufacturer.
Keep a record of the part code VC 1 K1F1P5E512 so that spare or replacement meters match the bearing, material, seal and electronics letters precisely.
If the count appears to drift, check for air in the line and compare the reading against a reference at the same viscosity; gear meters are sensitive to dirt but not to flow profile.
VC 1 K1F1P5E512 FAQ summary
What resolution does KRACHT VC 1 K1F1P5E512 have? 35 301 pulse/l, or 141 204 pulse/l with 4-fold evaluation of both channels; each pulse equals 0.028328 cm3.
What is the highest pulse frequency of VC 1 K1F1P5E512? 47 067 Hz, which the evaluating counter must be able to process.
Does VC 1 K1F1P5E512 detect flow direction? Yes, the encoder versions detect the direction of flow.
Documents and quotation
A PDF copy of the KRACHT VC gear type flow meter datasheet is attached to this listing; it extends over type key, technical data, electronics, drawings and weights relevant to VC 1 K1F1P5E512.
To request a quotation, send an RFQ that names the exact code VC 1 K1F1P5E512, the quantity and the delivery place in Oman or the GCC. A photo of the type plate supports us verify each code position.
Please note that Seven Star LLC is an independent supplier serving Oman and the GCC, not affiliated with the manufacturer.
Other Models in the Vc Gear Flow Meter Range
Seven Star LLC supplies models from the Vc Gear Flow Meter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| KRACHT VC 3 G1E1P2SH Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VC 5 K2K3R2HH Gear Flow Meter | Turbine & Positive Displacement Flowmeters | View details |
| KRACHT VC 1 K1F1P5E512 Gear Flow Meter | Turbine & Positive Displacement Flowmeters | You are viewing this model |
Datasheets & Documents
- Datasheet KRACHT VC 1 K1F1P5E512 Gear Flow Meter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KRACHT is the German maker of gear pumps, gear flow meters, hydraulic valves, motors and cylinders. The company was entered in the trade register in 1911 as Hillebrand & Kracht OHG and is based in Werdohl, in the Sauerland region of Germany. For most of its history it was a medium-sized family company; in January 2024 it became part of the Atlas Copco Group, in the Power and Flow division.
Seven Star LLC lists KRACHT pumps, flow meters, valves and hydraulic motors, and sources them by type key for machinery and marine users in Oman.
KRACHT company profile
| Founded | 1911, registered as Hillebrand & Kracht OHG |
|---|---|
| Headquarters | Werdohl, North Rhine-Westphalia, Germany; in today's premises since 1971 |
| Ownership | Atlas Copco Group since January 2024 (Power and Flow division, Power Technique business area); previously a family company |
| Size | About 440 employees and revenue of about EUR 72 million in 2022, as reported by Atlas Copco |
| Subsidiaries | USA, China and Hungary (KRACHT Hidraulik Kft.) |
| Product families | External gear pumps for lube oil, fuel and process duty, VC and VZ gear flow meters, pressure and flow control valves, hydraulic motors and cylinders |
Milestones
- 1911: Hillebrand & Kracht OHG is entered in the trade register.
- 1971: The company moves into its present premises in Werdohl.
- 1992: A gear manufacturer in Hungary is acquired, today KRACHT Hidraulik Kft.
- 2023–2024: Atlas Copco agrees to buy KRACHT in December 2023 and completes the deal in January 2024.
KRACHT pumps, flow meters and valves listed
The listing follows four product groups, pumps, fluid measurement, valves and drives:
- Pump technology: KF gear pumps for transfer of lubricating and other fluids, the KF-F version for fuels, and KP high pressure gear pumps
- Fluid measurement technology: gear type flow meters such as the VCA in aluminum
- Valve technology: SPV and SPVF pressure relief valves, the DBD directly controlled poppet valve, HV and HVF pilot operated valves and the DV B hydraulically pilot controlled valve
- Drive technology: KM hydraulic gear motors
Where KRACHT equipment is used
KRACHT equipment serves the marine, renewable energy, process technology and hydraulics industries. In practice that means lube oil and fuel oil transfer on engines, gearboxes and compressors, oil supply units, and metering of oils, resins, paints and other viscous media with gear flow meters in dosing and test bench systems. Enquiries from the GCC are mostly for a KRACHT pump or valve fitted to an imported machine or a ship's auxiliary system.
KRACHT products we list
Ordering KRACHT parts: what we need
KRACHT products carry a type key on the nameplate that encodes size, direction of rotation, shaft end, housing and seal material, connections and special numbers. An example from this page is SPV 10 L1G 1 A 12. Send the complete key and the serial or order number shown with it. If the plate is damaged, send the fluid and viscosity, flow rate, operating pressure and temperature, drive speed, port type and size, and photos with main dimensions. For KRACHT flow meters add the measuring range and the pickup or electronics required. We compare the key with KRACHT documentation and supply the manufacturer's data sheet on request.
Frequently requested KRACHT models: KRACHT Pump Technology Series.
Facts checked against KRACHT company literature and Atlas Copco's acquisition announcements, October 2026.
Browse KRACHT products by category: Safety Relief Valves, Pumps, Flowmeters, Electromotors.
FAQ
Questions about the KRACHT VC 1 K1F1P5E512 Gear Flow Meter
Answers from our engineering team on installation, compatibility and integration.
01What resolution does KRACHT VC 1 K1F1P5E512 have?
35 301 pulse/l, or 141 204 pulse/l with 4-fold evaluation of both channels; each pulse equals 0.028328 cm3.
02What is the maximum pulse frequency of VC 1 K1F1P5E512?
47 067 Hz, which the evaluating counter must be able to process.
03Does VC 1 K1F1P5E512 detect flow direction?
Yes, the encoder versions detect the direction of flow.
04How heavy is VC 1 K1F1P5E512?
5.4 kg for the encoder version of size 1 in spheroidal cast iron.
05What is the measuring range of VC 1 K1F1P5E512?
0.4 to 80 l/min with a starting point of 0.02 l/min.


















Reviews