Brand: MICHELL Instruments
Michell OPT401 Optidew 401 Chilled Mirror Hygrometer
Description
Michell OPT401 overview: bench top chilled mirror hygrometer
Michell OPT401 is the parent order code of the Michell Optidew 401, a bench top chilled mirror hygrometer with display. The order-code sheet describes it as combining high accuracy with a durable dew-point sensor, a platinum resistance thermometer, 4-20 mA outputs and SD card, USB and RS485 communications as standard.
The datasheet gives a dew-point accuracy of plus or minus 0.15 degrees Celsius and a wide range from minus 40 to plus 120 degrees Celsius dew point depending on the sensor, with a hybrid chilled mirror sensor that responds as quickly as polymer humidity sensors.
It is used as a reference humidity instrument for climatic and environmental chambers and for process humidity control.
The image shows the Optidew instruments and sensor from the manufacturer datasheet.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list Michell OPT401 so that maintenance, instrumentation and procurement teams can quote the exact code that appears in the manufacturer documentation.
Key features of OPT401
- Chilled mirror hybrid sensor with fast response: stable measurement at plus 10 degrees Celsius dew point within one minute.
- Dew-point accuracy plus or minus 0.15 degrees Celsius and temperature accuracy plus or minus 0.1 degrees Celsius.
- Sensor choices: single stage POM head, two stage POM head, or harsh environment PEEK head up to plus 120 degrees Celsius dew point.
- Touch-screen interface, two 0 or 4 to 20 mA outputs and optional pressure transmitter for ppmV and g/kg calculations.
- Communications: RS485, USB and SD card, with Ethernet and Modbus TCP as an option.
- Supply 100 to 240 V AC.
OPT401 technical specifications
The table below lists values published by the manufacturer for the product family of OPT401. Where a value depends on the ordered configuration, the table says so and the order-code sheet governs.
| Parameter | Value |
|---|---|
| Order code (parent) | OPT401, Optidew 401 chilled mirror hygrometer, bench top with display |
| Dew-point accuracy | Plus or minus 0.15 degC |
| Temperature accuracy | Plus or minus 0.1 degC |
| Dew-point range | Single stage minus 25 to plus 90 degC; dual stage minus 40 to plus 90 degC; harsh environment minus 40 to plus 120 degC |
| Response | Stable at plus 10 degC dp within 1 minute |
| Pressure transmitter (optional) | 0 to 160 kPa or 0 to 2500 kPa; accuracy plus or minus 0.25 percent FS |
| Analog outputs | Two 0/4 to 20 mA, maximum load 500 ohm |
| Supply voltage | 100 to 240 V AC, 50 to 60 Hz |
| Ingress protection | IP54 standard; IP65 optional |
| Sensor pressure | 2500 kPa maximum |
Typical applications of OPT401 in Oman and the GCC
- Reference humidity instrument for climatic and environmental chambers.
- Inlet air measurement for engine testing and HVAC testing.
- Clean room environmental monitoring.
- Coating process monitoring and control of humidity for metallurgical processes.
In Oman and across the GCC, moisture measurement matters wherever gas has to stay dry: gas gathering and processing plants, LNG and gas-to-power facilities, refineries and petrochemical complexes, desalination and utility compressed-air systems, and industrial gas and hydrogen users. High ambient temperatures and humidity make dryer performance and sensor drift a real operating cost, so a transmitter such as OPT401 is usually specified against a defined dew-point or ppmV target and a documented calibration.
Selection and compatibility notes
The OPT401 order string selects the sensor (A single stage POM, B two stage POM, C harsh environment PEEK), calibration (standard traceable, UKAS or ISO 17025 dew point, or UKAS RH), the cable length and the communication option. An example on the sheet is OPT401-CBAB.
For wall mount or transmitter versions see OPT501.
Confirm four things before ordering OPT401: the dew-point or ppmV range you need, the process connection and sample handling arrangement, the hazardous-area certification that your site requires, and the electrical interface of your control system. Because Michell builds many variants from one parent code, quote the complete configured code from the order-code sheet where one applies, and tell us the operating pressure so that ppmV conversions are programmed correctly.
Installation and commissioning of OPT401
Mount the sensor in the process or sampling arrangement and keep cable runs within the cable options of the sheet; the ambient temperature sensor is included with the cables.
Mount the sensor in a sampling arrangement that delivers a clean, representative gas stream at a controlled flow, keep sample lines short and use stainless steel or other low-adsorption tubing, and avoid dead legs, because trace moisture adsorbs on tubing walls and slows the response. Wire the 4-20 mA loop with screened cable, check loop supply and load against the datasheet limits, and allow the sensor to stabilise on dry gas before judging the first readings. Record the as-found reading and the calibration certificate number at commissioning.
Maintenance, calibration and service
Chilled mirror sensors need periodic cleaning; the sheet lists CM-CLN-KIT mirror cleaning materials, and spare sensors OPT2-STD-1, OPT2-STD-2 and OPT2-HES-2.
Ceramic moisture sensors are stable, but periodic verification keeps a dryer control loop honest. Plan recalibration or sensor exchange at the interval set by your quality system, inspect the sensor guard and seals at each visit, and replace guards that are clogged by particulates or contaminated by oil mist. If a reading drifts, check the sample system for leaks and condensate before suspecting the sensor.
Related products and ordering notes for OPT401
- OPT501: Optidew 501 wall mount or transmitter version.
- OPT2-STD-2: two stage dew-point sensor.
- OPT2-PS25: pressure transmitter 0 to 2500 kPa.
When you request OPT401, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. Our team can also check related codes from the same order-code sheet so that one RFQ covers the transmitter or analyzer, its consumables and its calibration needs.
Frequently asked questions about OPT401
- What is OPT401? OPT401 is the manufacturer parent code for the Optidew 401 bench top chilled mirror hygrometer with display.
- What does OPT401 suit? It suits reference-grade dew-point and humidity measurement in laboratories, test chambers and industrial humidity control.
- What sensor options does OPT401 have? The order code offers a single stage POM head, a two stage POM head, or a harsh environment two stage PEEK head with dew-point range up to plus 120 degrees Celsius.
- What should I send with an RFQ for OPT401? Send the part number OPT401, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.
Documents and quotation
A manufacturer document is available for the product family of OPT401 and we can send it with your quotation where the family datasheet applies. To request pricing and lead time, send an RFQ to Seven Star LLC with the part number OPT401, the quantity, the full configuration or host-instrument details, the delivery location and any certificate requirements such as material certificates or calibration documents. We will confirm availability and respond with a quotation for OPT401 in writing.
Datasheets & Documents
- Datasheet Michell OPT401 Optidew 401 Chilled Mirror Hygrometer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the Michell OPT401 Optidew 401 Chilled Mirror Hygrometer
Answers from our engineering team on installation, compatibility and integration.
01What is OPT401?
OPT401 is the manufacturer parent code for the Optidew 401 bench top chilled mirror hygrometer with display.
02What does OPT401 suit?
It suits reference-grade dew-point and humidity measurement in laboratories, test chambers and industrial humidity control.
03What sensor options does OPT401 have?
The order code offers a single stage POM head, a two stage POM head, or a harsh environment two stage PEEK head with dew-point range up to plus 120 degrees Celsius.
04Can Seven Star LLC supply OPT401 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for OPT401?
Send the part number OPT401, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.


















Reviews
There are no reviews yet.