Brand: MICHELL Instruments
Michell EA2-TX Easidew 2-Wire Dew-Point Transmitter 5/8 UNF
Description
Michell EA2-TX overview: industrial two-wire dew-point transmitter
Michell EA2-TX is the parent order code of the Michell Easidew two-wire dew-point transmitter with a 4-20 mA output and a 5/8 inch UNF process thread. It is the standard industrial transmitter of the Easidew family and is widely used for compressed air dryers and process gases.
The datasheet gives a measurement range from minus 110 up to plus 20 degrees Celsius dew point, an accuracy of plus or minus 2 degrees Celsius dew point, a supply of 12 to 28 V DC and a process pressure rating of 450 barg. A traceable 13-point calibration certificate comes with the transmitter.
Buyers searching for Michell EA2-TX typically need a replacement for an installed Easidew, so exact configuration details matter.
The image shows Easidew transmitters from the manufacturer datasheet, the family that the EA2-TX code orders.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list EA2-TX so that maintenance, instrumentation and procurement teams can quote the exact code that appears in the manufacturer documentation.
Key features of EA2-TX
- Dew-point range of minus 110 to plus 20 degrees Celsius with minus 100 to plus 20 degrees Celsius as an alternative standard range; ppmV output scaling up to 3000 ppmV.
- Two-wire 4-20 mA output with MiniDIN 43650 form C connector, mating connector supplied as standard.
- 316 stainless steel body, IP66 and NEMA 4, weight 150 g, and 5/8 inch 18 UNF process connection.
- Process pressure rating of 450 barg with HDPE guard for particulates above 10 micron or stainless steel sintered guard above 80 micron.
- Optional cleaning for enriched oxygen service and optional material certificates.
- Sensor exchange and recalibration programmes offered by the manufacturer.
EA2-TX technical specifications
The table below lists values published by the manufacturer for the product family of EA2-TX. Where a value depends on the ordered configuration, the table says so and the order-code sheet governs.
| Parameter | Value |
|---|---|
| Order code (parent) | EA2-TX, Easidew 2-wire dew-point transmitter (4-20 mA, 5/8 inch UNF) |
| Measurement range | Minus 110 to plus 20 degC dp or minus 100 to plus 20 degC dp |
| Accuracy | Plus or minus 2 degC dew point |
| Response time | 5 minutes to T95 (dry to wet) |
| Repeatability | 0.5 degC dew point |
| Calibration | Traceable 13-point certificate |
| Output | 4-20 mA two-wire current source, user configurable |
| Supply voltage | 12 to 28 V DC |
| Load resistance | Maximum 250 ohm at 14 V; 500 ohm at 24 V |
| Operating temperature | Minus 40 to plus 60 degC; compensated minus 20 to plus 50 degC |
| Operating pressure | 45 MPa (450 barg) maximum |
| Flow rate | 1 to 5 Nl/min in sampling block; 0 to 10 m/s direct insertion |
| Ingress protection | IP66; NEMA 4 |
| Electrical connection | MiniDIN 43650 form C |
| Process connection | 5/8 inch 18 UNF, 316 stainless steel |
| Weight | 150 g |
Typical applications of EA2-TX in Oman and the GCC
- Compressed air Class 1 to Class 6 dryers, including membrane and adsorption dryers.
- Breathing air and medical air quality checks.
- Hydrogen coolant, inert and bulk gases, welding gases.
- Glove boxes and oxygen purity applications with the oxygen-cleaned option.
In Oman and across the GCC, moisture measurement matters wherever gas has to stay dry: gas gathering and processing plants, LNG and gas-to-power facilities, refineries and petrochemical complexes, desalination and utility compressed-air systems, and industrial gas and hydrogen users. High ambient temperatures and humidity make dryer performance and sensor drift a real operating cost, so a transmitter such as EA2-TX is usually specified against a defined dew-point or ppmV target and a documented calibration.
Selection and compatibility notes
The EA2-TX order string combines the range in square form, such as minus 100 to plus 20 degrees Celsius, with a guard code: HD for the HDPE guard or SS for the sintered stainless steel guard. A J1 option cleans the unit for oxygen service and is listed as available with the sintered guard.
If your plant uses a 3/4 inch UNF thread, look at EA34-TX; for M12 connectors and G1/2 BSP threads, look at EA2-TX-M12.
Confirm four things before ordering EA2-TX: the dew-point or ppmV range you need, the process connection and sample handling arrangement, the hazardous-area certification that your site requires, and the electrical interface of your control system. Because Michell builds many variants from one parent code, quote the complete configured code from the order-code sheet where one applies, and tell us the operating pressure so that ppmV conversions are programmed correctly.
Installation and commissioning of EA2-TX
Use the sample block and cable accessories on the order-code sheet: CSB 5/8 inch UNF sample block, EA2-SAM sampler kit, adaptor collars APT-PAN, APT-GEI and APT-TSO, and cables EA2-CAB-0.8 to EA2-CAB-10 with MiniDIN socket.
Mount the sensor in a sampling arrangement that delivers a clean, representative gas stream at a controlled flow, keep sample lines short and use stainless steel or other low-adsorption tubing, and avoid dead legs, because trace moisture adsorbs on tubing walls and slows the response. Wire the 4-20 mA loop with screened cable, check loop supply and load against the datasheet limits, and allow the sensor to stabilise on dry gas before judging the first readings. Record the as-found reading and the calibration certificate number at commissioning.
Maintenance, calibration and service
Service exchange EA2-TX-X and recalibration EA2-TX-Recal are listed with traceable certificates, and spares include EA2-HDPE guards in packs of ten, SSG sintered guard, BS-58-PK5 bonded seals, EA2-SC and EA2-SCG.
Ceramic moisture sensors are stable, but periodic verification keeps a dryer control loop honest. Plan recalibration or sensor exchange at the interval set by your quality system, inspect the sensor guard and seals at each visit, and replace guards that are clogged by particulates or contaminated by oil mist. If a reading drifts, check the sample system for leaks and condensate before suspecting the sensor.
Related products and ordering notes for EA2-TX
- EA2-TX-M12: Easidew with M12 connector and Modbus RTU.
- EA34-TX: Easidew 34 with 3/4 inch UNF thread.
- EA2-OL: Easidew Online hygrometer with display and alarms.
When you request EA2-TX, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. Our team can also check related codes from the same order-code sheet so that one RFQ covers the transmitter or analyzer, its consumables and its calibration needs.
Frequently asked questions about EA2-TX
- What is EA2-TX? EA2-TX is the manufacturer parent code for the Easidew two-wire dew-point transmitter with 4-20 mA output and a 5/8 inch UNF thread.
- What does EA2-TX suit? It suits dew-point measurement in compressed air and process gas, for example dryers, breathing air, inert gases and glove boxes, outside hazardous areas.
- How is the EA2-TX range specified? The order string includes the range, minus 100 to plus 20 degrees Celsius or minus 110 to plus 20 degrees Celsius, or a non-standard range in dew point, ppmV or other units, plus the guard type.
- What should I send with an RFQ for EA2-TX? Send the part number EA2-TX, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.
Documents and quotation
A manufacturer document is available for the product family of EA2-TX and we can send it with your quotation where the family datasheet applies. To request pricing and lead time, send an RFQ to Seven Star LLC with the part number EA2-TX, the quantity, the full configuration or host-instrument details, the delivery location and any certificate requirements such as material certificates or calibration documents. We will confirm availability and respond with a quotation for EA2-TX in writing.
Other Models in the Michell Easidew Range
Seven Star LLC supplies models from the Michell Easidew range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Michell EA2-TX Easidew 2-Wire Dew-Point Transmitter 5/8 UNF | Humidity & Dew Point Instruments | You are viewing this model |
| Michell EA2-TX-M12 Easidew Dew-Point Transmitter M12 Connector | Humidity & Dew Point Instruments | View details |
| Michell EA34-TX Easidew 34 Dew-Point Transmitter 3/4 UNF | Humidity & Dew Point Instruments | View details |
| Michell EA2-OL Easidew Online Dew-Point Hygrometer | Humidity & Dew Point Instruments | View details |
Datasheets & Documents
- Datasheet Michell EA2-TX Easidew 2-Wire Dew-Point Transmitter 5/8 UNF Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the Michell EA2-TX Easidew 2-Wire Dew-Point Transmitter
Answers from our engineering team on installation, compatibility and integration.
01What is EA2-TX?
EA2-TX is the manufacturer parent code for the Easidew two-wire dew-point transmitter with 4-20 mA output and a 5/8 inch UNF thread.
02What does EA2-TX suit?
It suits dew-point measurement in compressed air and process gas, for example dryers, breathing air, inert gases and glove boxes, outside hazardous areas.
03How is the EA2-TX range specified?
The order string includes the range, minus 100 to plus 20 degrees Celsius or minus 110 to plus 20 degrees Celsius, or a non-standard range in dew point, ppmV or other units, plus the guard type.
04Can Seven Star LLC supply EA2-TX in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for EA2-TX?
Send the part number EA2-TX, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.