Michell EA2-IS-TX Easidew I.S. Intrinsically Safe Transmitter

Description

Michell EA2-IS-TX overview: compact intrinsically safe dew-point transmitter

Michell EA2-IS-TX is the parent order code of the Michell Easidew I.S., a compact intrinsically safe dew-point transmitter for hazardous-area gas applications. The datasheet lists IECEx, QPS, ATEX and UKCA certification and describes it as designed for flammable or explosive gas locations.

The transmitter has a 4-20 mA two-wire output, a dew-point accuracy of plus or minus 2 degrees Celsius, a 525 barg operating pressure rating and a choice of 5/8 inch UNF, G1/2 BSP or 3/4 inch UNF process connection. It is the small-body alternative to the Easidew PRO I.S.

Operators who need intrinsic safety on compressed air, nitrogen, hydrogen or fuel gas lines look for the Michell EA2-IS-TX code because it uses the same ceramic sensing technology as the wider Easidew family.

The image shows the Easidew I.S. transmitter from the manufacturer datasheet, the product the EA2-IS-TX code orders.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list EA2-IS-TX so that maintenance, instrumentation and procurement teams can quote the exact code that appears in the manufacturer documentation.

Key features of EA2-IS-TX

  • Intrinsically safe: ATEX and UKCA II 1 G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4 Ga, TR CU 0Ex ia IIC T4 Ga, with ambient limits minus 20 to plus 70 degrees Celsius.
  • Two-wire 4-20 mA output, user configurable over range, supply 12 to 28 V DC.
  • Range of minus 100 or minus 110 to plus 20 degrees Celsius dew point; ppmV scaling for gas up to 3000 ppmV.
  • Process connection choice in the order code: G1/2 BSP, 3/4 inch UNF or 5/8 inch UNF.
  • Operating pressure of 52.5 MPa (525 barg) with an overpressure rating of 90 MPa (900 barg).
  • IP66 and NEMA 4 housing with sintered or HDPE guard options and optional oxygen cleaning.

EA2-IS-TX technical specifications

The table below lists values published by the manufacturer for the product family of EA2-IS-TX. Where a value depends on the ordered configuration, the table says so and the order-code sheet governs.

Parameter Value
Order code (parent) EA2-IS-TX, Easidew intrinsically safe transmitter (2-wire, 4-20 mA)
Measurement range Minus 100 to plus 20 degC dp or minus 110 to plus 20 degC dp
Accuracy Plus or minus 2 degC dew point
Response time 5 minutes to T95 (dry to wet)
Repeatability 0.5 degC dew point
Calibration Traceable 7-point calibration certificate
Output 4-20 mA two-wire, user configurable
Supply voltage 12 to 28 V DC
Current consumption 20 mA maximum
Operating temperature Minus 40 to plus 60 degC; compensated minus 20 to plus 50 degC
Operating pressure 52.5 MPa (525 barg) maximum; overpressure 90 MPa
Ingress protection IP66; NEMA 4
Intrinsic safety ATEX/UKCA II 1 G Ex ia IIC T4 Ga; IECEx Ex ia IIC T4 Ga
Process connections G1/2 inch BSP, 3/4 inch UNF or 5/8 inch UNF

Typical applications of EA2-IS-TX in Oman and the GCC

  • Compressed air and inert gas lines in classified areas.
  • Hydrogen and fuel gas drying checks.
  • Moisture monitoring in chemical and petrochemical gas supply.
  • Welding and process gases in hazardous locations.

In Oman and across the GCC, moisture measurement matters wherever gas has to stay dry: gas gathering and processing plants, LNG and gas-to-power facilities, refineries and petrochemical complexes, desalination and utility compressed-air systems, and industrial gas and hydrogen users. High ambient temperatures and humidity make dryer performance and sensor drift a real operating cost, so a transmitter such as EA2-IS-TX is usually specified against a defined dew-point or ppmV target and a documented calibration.

Selection and compatibility notes

The EA2-IS-TX order string lets you choose process connection (A for G1/2 BSP, B for 3/4 inch UNF, C for 5/8 inch UNF), range, guard type and oxygen cleaning. Non-standard ranges are described by a zero value, full-scale value, unit and pressure.

Where more accuracy or higher integrity is needed, compare with the Easidew PRO I.S., which lists a plus or minus 1 degree Celsius accuracy band.

Confirm four things before ordering EA2-IS-TX: the dew-point or ppmV range you need, the process connection and sample handling arrangement, the hazardous-area certification that your site requires, and the electrical interface of your control system. Because Michell builds many variants from one parent code, quote the complete configured code from the order-code sheet where one applies, and tell us the operating pressure so that ppmV conversions are programmed correctly.

Installation and commissioning of EA2-IS-TX

An intrinsically safe transmitter must be connected through a certified barrier or galvanic isolator; the order-code sheet lists a Pepperl and Fuchs isolator as an accessory under GI-PF-01. Check loop parameters against the certificate before wiring.

Mount the sensor in a sampling arrangement that delivers a clean, representative gas stream at a controlled flow, keep sample lines short and use stainless steel or other low-adsorption tubing, and avoid dead legs, because trace moisture adsorbs on tubing walls and slows the response. Wire the 4-20 mA loop with screened cable, check loop supply and load against the datasheet limits, and allow the sensor to stabilise on dry gas before judging the first readings. Record the as-found reading and the calibration certificate number at commissioning.

Maintenance, calibration and service

The manufacturer lists EA2-IS-RECAL for recalibration with a traceable certificate, together with spares such as EA2-SC connector socket, EA2-SCG gasket, BS-12-PK5 bonded seals and KF40 adaptor flanges.

Ceramic moisture sensors are stable, but periodic verification keeps a dryer control loop honest. Plan recalibration or sensor exchange at the interval set by your quality system, inspect the sensor guard and seals at each visit, and replace guards that are clogged by particulates or contaminated by oil mist. If a reading drifts, check the sample system for leaks and condensate before suspecting the sensor.

Related products and ordering notes for EA2-IS-TX

  • EPR-IS: Easidew PRO I.S. with higher accuracy and pressure range.
  • EA2-TX: standard Easidew transmitter for non-hazardous areas.
  • EA2-TX-M12: Easidew with M12 connector and Modbus capability.

When you request EA2-IS-TX, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. Our team can also check related codes from the same order-code sheet so that one RFQ covers the transmitter or analyzer, its consumables and its calibration needs.

Frequently asked questions about EA2-IS-TX

  • What is EA2-IS-TX? EA2-IS-TX is the manufacturer parent code for the Easidew I.S. intrinsically safe two-wire dew-point transmitter.
  • What does EA2-IS-TX suit? It suits dew-point measurement in gas in hazardous areas where intrinsically safe equipment is required, in compressed air, inert gases, hydrogen and process gas supply.
  • Which process connections does EA2-IS-TX offer? The order code offers G1/2 inch BSP, 3/4 inch UNF and 5/8 inch UNF process connections, chosen when the transmitter is configured.
  • What should I send with an RFQ for EA2-IS-TX? Send the part number EA2-IS-TX, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.

Documents and quotation

A manufacturer document is available for the product family of EA2-IS-TX and we can send it with your quotation where the family datasheet applies. To request pricing and lead time, send an RFQ to Seven Star LLC with the part number EA2-IS-TX, the quantity, the full configuration or host-instrument details, the delivery location and any certificate requirements such as material certificates or calibration documents. We will confirm availability and respond with a quotation for EA2-IS-TX in writing.

Datasheets & Documents
  • PDF Datasheet Michell EA2-IS-TX Easidew I.S. Intrinsically Safe Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).

Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.

MICHELL Instruments company profile

Founded 1974, Cambridge, England, by Andrew Michell
Headquarters Ely, Cambridgeshire, United Kingdom, since 2007
Ownership Process Sensing Technologies (PST)
Technology Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell)
Product families Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers

Milestones

  • 1974: Andrew Michell founds Michell Instruments in Cambridge.
  • 2007: The company moves to Ely, Cambridgeshire.
  • 2024: Michell marks 50 years, now as part of PST.

Michell product families on this page

The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.

Where Michell analyzers are used

Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.

MICHELL Instruments products we list

Family Examples
Gas Analyzer Systems Easidew PRO I.S. Intrinsically Safe Mois…, Michell CD2-WDC-002 Water Dew-Point Sens…, Michell Condumax II Hydrocarbon Dew-Poin…, Easidew EA2 Dew Point Transmitter, Michell OptiPEAK TDL600 Moisture in Natu…, Michell Promet EExd Process Moisture Ana…, Michell S8000 Precision Chilled Mirror H…
Gas Analyzer Accessories MICHELL CD2-SX-WDC-002 Water Dew-Point S…, Michell Ceramic Impedance Moisture Senso…, Michell Condumax II CD2-SCR-002 Hydrocar…

Ordering Michell parts: what we need

For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.

Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.

FAQ

Questions about the Michell EA2-IS-TX Easidew I.S. Intrinsically Safe

Answers from our engineering team on installation, compatibility and integration.

01What is EA2-IS-TX?
EA2-IS-TX is the manufacturer parent code for the Easidew I.S. intrinsically safe two-wire dew-point transmitter.
02What does EA2-IS-TX suit?
It suits dew-point measurement in gas in hazardous areas where intrinsically safe equipment is required, in compressed air, inert gases, hydrogen and process gas supply.
03Which process connections does EA2-IS-TX offer?
The order code offers G1/2 inch BSP, 3/4 inch UNF and 5/8 inch UNF process connections, chosen when the transmitter is configured.
04Can Seven Star LLC supply EA2-IS-TX in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for EA2-IS-TX?
Send the part number EA2-IS-TX, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.