Michell EPR-LQ-IS Easidew PRO LQ I.S. Moisture-in-Liquids Transmitter

Description

Michell EPR-LQ-IS overview: intrinsically safe moisture-in-liquids transmitter

Michell EPR-LQ-IS is the parent order code of the Easidew PRO LQ I.S., the intrinsically safe two-wire transmitter for moisture in liquids. The manufacturer order-code sheet explains that it must be programmed with saturation constants for the liquid in which the measurement is made.

The datasheet states a capability of 0 to 1000 ppmW, factory configured to the required range and application, a six-point look-up table for saturation constants over 0 to plus 50 degrees Celsius, and stored constants for ten common liquids, or constants entered manually.

It shares the stainless steel body, 525 barg rating and intrinsically safe certification of the gas version, EPR-IS.

The image shows the Easidew PRO I.S. transmitter from the manufacturer datasheet; the liquids version uses the same intrinsically safe housing.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list Michell EPR-LQ-IS so that maintenance, instrumentation and procurement teams can quote the exact code that appears in the manufacturer documentation.

Key features of EPR-LQ-IS

  • Moisture in liquids, 0 to 1000 ppmW capability, configured to the customer liquid and range.
  • Look-up table of six points for saturation constants from 0 to plus 50 degrees Celsius.
  • Constants for ten common liquids can be loaded using the application software.
  • Intrinsically safe: ATEX and UKCA II 1 G Ex ia IIC T4 Ga, IECEx and cQPSus certification.
  • 4-20 mA two-wire output with 23 mA sensor fault diagnostic.
  • Liquid flow guidance of 0.1 to 0.3 L/min through the sample block, or 0.1 to 1 m/s direct insertion.

EPR-LQ-IS technical specifications

The table below lists values published by the manufacturer for the product family of EPR-LQ-IS. Where a value depends on the ordered configuration, the table says so and the order-code sheet governs.

Parameter Value
Order code (parent) EPR-LQ-IS, 2-wire moisture in liquids transmitter, I.S. certified
Measurement Moisture content in liquids, ppmW
Range 0 to 1000 ppmW capability, factory configured
Output 4-20 mA two-wire
Supply voltage 12 to 28 V DC
Saturation constants Six-point look-up table to 1000 ppmW over 0 to plus 50 degC; ten common liquids programmable
Operating pressure 52.5 MPa (525 barg) maximum
Operating temperature Minus 40 to plus 60 degC
Flow rate 0.1 to 0.3 L/min via sample block; 0.1 to 1 m/s direct insertion
Intrinsic safety ATEX/UKCA II 1 G Ex ia IIC T4 Ga; IECEx Ex ia IIC T4 Ga
Housing 316 stainless steel, IP66, NEMA 4
Weight 1.27 kg

Typical applications of EPR-LQ-IS in Oman and the GCC

  • Water in propane, butane, pentane and other light hydrocarbon liquids.
  • Petrochemical process liquids and aromatic solvents such as toluene.
  • Catalyst protection upstream of reactors.
  • Quality control of liquid feedstocks in polymer production.

In Oman and across the GCC, moisture measurement matters wherever gas has to stay dry: gas gathering and processing plants, LNG and gas-to-power facilities, refineries and petrochemical complexes, desalination and utility compressed-air systems, and industrial gas and hydrogen users. High ambient temperatures and humidity make dryer performance and sensor drift a real operating cost, so a transmitter such as EPR-LQ-IS is usually specified against a defined dew-point or ppmV target and a documented calibration.

Selection and compatibility notes

The liquid is selected by a letter in the order code, with options named on the sheet as methane, propane, ethane, propylene, ethylene, butane, isobutane, pentane, toluene and cyclopentane, a user-programmed constant and a user-defined liquid. State the ppmW range at the time of order.

As an intrinsically safe unit it needs a certified barrier or isolator in the loop.

Confirm four things before ordering EPR-LQ-IS: the dew-point or ppmV range you need, the process connection and sample handling arrangement, the hazardous-area certification that your site requires, and the electrical interface of your control system. Because Michell builds many variants from one parent code, quote the complete configured code from the order-code sheet where one applies, and tell us the operating pressure so that ppmV conversions are programmed correctly.

Installation and commissioning of EPR-LQ-IS

Liquid measurements depend on stable flow and temperature across the sensor. Use a sample block with the flow stated by the manufacturer, keep the sensor wetted by liquid only, and avoid gas pockets.

Mount the sensor in a sampling arrangement that delivers a clean, representative gas stream at a controlled flow, keep sample lines short and use stainless steel or other low-adsorption tubing, and avoid dead legs, because trace moisture adsorbs on tubing walls and slows the response. Wire the 4-20 mA loop with screened cable, check loop supply and load against the datasheet limits, and allow the sensor to stabilise on dry gas before judging the first readings. Record the as-found reading and the calibration certificate number at commissioning.

Maintenance, calibration and service

The order-code sheet lists service exchange and recalibration for the family, and spare codes such as SSG, EPR-SC, EPR-14127 and EPR-BRK. Stainless steel tags EPR-LQ-IS-TAG are also listed.

Ceramic moisture sensors are stable, but periodic verification keeps a dryer control loop honest. Plan recalibration or sensor exchange at the interval set by your quality system, inspect the sensor guard and seals at each visit, and replace guards that are clogged by particulates or contaminated by oil mist. If a reading drifts, check the sample system for leaks and condensate before suspecting the sensor.

Related products and ordering notes for EPR-LQ-IS

  • EPR-IS: gas version of the Easidew PRO I.S.
  • XP-LQ: flameproof moisture-in-liquids transmitter.
  • GI-PF-01: galvanic isolator listed by the manufacturer as an accessory.

When you request EPR-LQ-IS, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. Our team can also check related codes from the same order-code sheet so that one RFQ covers the transmitter or analyzer, its consumables and its calibration needs.

Frequently asked questions about EPR-LQ-IS

  • What is EPR-LQ-IS? EPR-LQ-IS is the manufacturer parent code for the Easidew PRO LQ I.S., a two-wire intrinsically safe moisture-in-liquids transmitter.
  • What does EPR-LQ-IS suit? It suits moisture monitoring in non-polar process liquids in hazardous areas, for example light hydrocarbons and aromatics, when programmed with the liquid saturation constants.
  • What must be specified when ordering EPR-LQ-IS? State the liquid, so the correct saturation constants are programmed, and the ppmW range needed. The order-code sheet lists letters for common liquids and a user-defined option.
  • What should I send with an RFQ for EPR-LQ-IS? Send the part number EPR-LQ-IS, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.

Documents and quotation

A manufacturer document is available for the product family of EPR-LQ-IS and we can send it with your quotation where the family datasheet applies. To request pricing and lead time, send an RFQ to Seven Star LLC with the part number EPR-LQ-IS, the quantity, the full configuration or host-instrument details, the delivery location and any certificate requirements such as material certificates or calibration documents. We will confirm availability and respond with a quotation for EPR-LQ-IS in writing.

Other Models in the Michell Easidew Pro Is Range

Seven Star LLC supplies models from the Michell Easidew Pro Is range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Michell EPR-IS Easidew PRO I.S. Intrinsically Safe TransmitterHumidity & Dew Point InstrumentsView details
Michell EPR-LQ-IS Easidew PRO LQ I.S. Moisture-in-Liquids TransmitterHumidity & Dew Point InstrumentsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Michell EPR-LQ-IS Easidew PRO LQ I.S. Moisture-in-Liquids Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).

Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.

MICHELL Instruments company profile

Founded 1974, Cambridge, England, by Andrew Michell
Headquarters Ely, Cambridgeshire, United Kingdom, since 2007
Ownership Process Sensing Technologies (PST)
Technology Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell)
Product families Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers

Milestones

  • 1974: Andrew Michell founds Michell Instruments in Cambridge.
  • 2007: The company moves to Ely, Cambridgeshire.
  • 2024: Michell marks 50 years, now as part of PST.

Michell product families on this page

The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.

Where Michell analyzers are used

Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.

MICHELL Instruments products we list

Family Examples
Gas Analyzer Systems Easidew PRO I.S. Intrinsically Safe Mois…, Michell CD2-WDC-002 Water Dew-Point Sens…, Michell Condumax II Hydrocarbon Dew-Poin…, Easidew EA2 Dew Point Transmitter, Michell OptiPEAK TDL600 Moisture in Natu…, Michell Promet EExd Process Moisture Ana…, Michell S8000 Precision Chilled Mirror H…
Gas Analyzer Accessories MICHELL CD2-SX-WDC-002 Water Dew-Point S…, Michell Ceramic Impedance Moisture Senso…, Michell Condumax II CD2-SCR-002 Hydrocar…

Ordering Michell parts: what we need

For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.

Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.

FAQ

Questions about the Michell EPR-LQ-IS Easidew PRO LQ I.S.

Answers from our engineering team on installation, compatibility and integration.

01What is EPR-LQ-IS?
EPR-LQ-IS is the manufacturer parent code for the Easidew PRO LQ I.S., a two-wire intrinsically safe moisture-in-liquids transmitter.
02What does EPR-LQ-IS suit?
It suits moisture monitoring in non-polar process liquids in hazardous areas, for example light hydrocarbons and aromatics, when programmed with the liquid saturation constants.
03What must be specified when ordering EPR-LQ-IS?
State the liquid, so the correct saturation constants are programmed, and the ppmW range needed. The order-code sheet lists letters for common liquids and a user-defined option.
04Can Seven Star LLC supply EPR-LQ-IS in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for EPR-LQ-IS?
Send the part number EPR-LQ-IS, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.