Brand: Legrand
Legrand 407673 DX3 6000 A 1-Pole 32 A C-Curve MCB 10 kA
Description
407673: Legrand DX3 6000 A 1-pole 32 A C-curve MCB, what the reference means
The Legrand 407673 is a single-pole modular miniature circuit breaker from the DX3 6000 A / 10 kA series. It is rated 32 A, has a C tripping curve and is 17.8 mm wide, one modular spacing. It is the basic building block of final-circuit protection for sockets, lighting groups, small motors, heaters and air-conditioning units in distribution boards.
The 6000 A in the family name is the rated breaking capacity under the household standard EN 60898-1, and the 10 kA is the ultimate breaking capacity under the industrial standard IEC 60947-2. The datasheet covers the 407662 to 407676 block of references that includes the Legrand 407673, so the position of the reference inside the block identifies the rating and curve.
Seven Star LLC supplies the Legrand 407673 in Oman and the GCC as an independent supplier in Muscat and is not affiliated with the manufacturer. If you have only a board schedule, send it and we will list the matching references.
Technical specifications of Legrand 407673
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Legrand / 407673 |
| Range | DX3 6000 A / 10 kA |
| Poles | 1P (1 protected pole, neutral not switched) |
| Rated current | 32 A |
| Tripping curve | C |
| Rated voltage | 230 V AC, 50 – 60 Hz |
| Breaking capacity Icn (EN 60898-1) | 6 kA at 230 V |
| Breaking capacity Icu (IEC 60947-2) | 10 kA at 230 V; Ics 75 percent of Icu |
| Energy limiting class | 3 |
| Rated insulation voltage Ui | 500 V |
| Impulse withstand Uimp | 4 kV |
| Width | 17.8 mm (1 module) |
| Height x depth | 94.8 x 77.8 mm (built-in depth 44 mm) |
| Terminals | Screw type; multi-wire 1.5 – 25 mm²; solid 1.5 – 35 mm² |
| Tightening torque | 2.5 Nm recommended (2 – 3 Nm) |
| Mounting | 35 mm DIN rail, supply from top or bottom |
| Protection | IP20, IK02, pollution degree 2 |
| Operating temperature | -25 °C to +70 °C |
| Storage temperature | -40 °C to +70 °C |
| Colour | Grey RAL 7035 |
How the C-curve of 407673 behaves
Two mechanisms work in one housing. A bimetal strip heats with the load current and bends to open the contacts on an overload, following a time-current characteristic with a non-tripping current of 1.13 In and a tripping current of 1.45 In within the conventional time. A magnetic coil reacts to a short circuit and trips the breaker within milliseconds when the current reaches a multiple of the rating. For the C curve this multiple is between 5 and 10 times In, which for a 32 A breaker means roughly 160 to 320 A.
C curve suits loads with moderate inrush such as lighting with electronic control gear, small motors and general sockets. B curve devices trip earlier and fit long cable runs with low fault current, while D curve devices tolerate high inrush from transformers and large motors. The class 3 energy limiting marking tells you that the breaker limits the let-through energy to a low level during a short circuit, which reduces stress on the cables.
Where 407673 fits in a board and related parts
The DX3 family is built around the same 17.8 mm module. Neighbouring references in the same series include higher breaking capacity versions such as the DX3 10000 A / 16 kA devices (for example 409071 and 409333), 25 kA versions (409799 and 409802) and a 6000 A device with 20 A rating (407929). Residual-current protection is added by RCCB devices such as 411761 or by RCBO combinations like 411161 and 411189.
Auxiliary contacts, shunt trips and add-on RCD blocks fit on the DX3 series, so the same board can be upgraded without changing the breakers. Hardware such as HX3 comb busbars supplies a row of breakers from the top or the bottom, because the terminals are located to suit both pin and fork busbars.
Selection and ordering checklist for 407673
- Check the load current and the cable: a 32 A C-curve breaker suits a 6 mm² copper circuit in many installation methods, subject to local wiring rules.
- Compare the prospective short-circuit current with 6 kA (EN 60898-1) and 10 kA (IEC 60947-2).
- Choose the curve: B for long runs, C for general loads, D for high inrush.
- Confirm single-pole use. A 1P device does not switch the neutral, so check the earthing system and local rules.
- Check the supply voltage: the rating is 230 V; for 400 V circuits use the 2P, 3P or 4P versions.
- Plan accessories: auxiliary contacts, shunt release, RCD add-on or labelling.
Installation, commissioning and maintenance of 407673
Snap the breaker onto the 35 mm rail in any of the permitted positions; the datasheet allows vertical, horizontal, upside-down and on-the-side mounting. Strip 11 mm of insulation, insert the conductor and tighten with a Pozidriv No. 2 or 5.5 mm flat screwdriver to the recommended 2.5 Nm. Use a ferrule on flexible cables where the project specifies it, and insert a label in the label holder so that the circuit can be identified.
When commissioning, operate the handle to confirm free movement, check the red and green contact position indicator and measure the loop impedance at the far end of the circuit to confirm that a fault would reach the magnetic trip level. Re-torque terminals after the first load cycles. A tripped breaker should be investigated before it is reset, and a device that has cleared a heavy fault should be checked or replaced according to the site procedure.
Typical applications in Oman and the GCC
The 407673 is typical for final circuits in residential towers, offices, schools, hospitals, camp buildings, workshops and small industrial boards across Oman and the Gulf. A 32 A circuit feeds air-conditioning compressors, water heaters, cooker circuits, ring or radial socket circuits and small pumps. In industrial plants it serves auxiliary circuits and small panels behind a larger moulded case breaker.
Because the operating limit is 70 °C inside the board and the load current drops with heat, boards in hot plant rooms need spacing and ventilation. Dust and humidity make periodic terminal inspection worthwhile, and 10 kA of breaking capacity gives a margin for most final circuits fed from a building transformer at some distance.
Information to send with an RFQ for 407673
- Part number 407673 and the quantity.
- Supply voltage and earthing system.
- Prospective short-circuit current at the board.
- Load type and cable size, if the curve or rating is to be confirmed.
- Any accessories or busbar kits needed with the breakers.
- Delivery location in Oman or the GCC and the required date.
Documents and quotation
A technical sheet for the DX3 6000 A / 10 kA series is attached on this page. It lists the range, dimensions, connection data, breaking capacities, curves and use in direct current.
Send the part number and the quantity to Seven Star LLC and we will confirm availability, lead time and matching accessories for your RFQ.
Datasheets & Documents
- Datasheet Legrand 407673 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Legrand is a French maker of electrical and digital building infrastructure, headquartered in Limoges. Its roots lie in a nineteenth-century porcelain workshop in Limoges, and it grew into one of the largest makers of wiring devices, circuit protection, cable management and data centre products. Legrand is listed on Euronext Paris and sells under brands including Legrand, Bticino and Cablofil.
Seven Star LLC, an independent supplier in Muscat, lists Legrand circuit breakers for electrical contractors and panel builders in Oman and the GCC, at present a DX3 4-pole miniature circuit breaker rated C32.
Legrand company profile
| Headquarters | Limoges, France |
|---|---|
| Listing | Euronext Paris |
| Brands | Legrand, Bticino, Cablofil, Zucchini |
| Product families | DX3 miniature circuit breakers and RCDs, wiring devices, cable trays, busbar trunking, UPS |
Legrand DX3 circuit breakers
DX3 is the Legrand family of modular protection devices for DIN rail mounting. The item on our site is a 4-pole MCB with a C tripping curve and a 32 A rated current. Three things besides the pole count define a breaker of this kind: the curve, the rated current and the breaking capacity printed on the front. Legrand catalogs DX3 breakers in 6000 A and 10000 A versions under separate references.
Ordering Legrand breakers: what we need
Send the Legrand catalog number printed on the device, a six-digit reference, where it is legible. Otherwise give the number of poles, the curve, the rated current, the breaking capacity and the voltage. Mention any auxiliary contact or residual current add-on module fitted beside the breaker, and the board type.
Facts checked against Legrand's published corporate information, October 2026.
Browse Legrand products by category: Circuit Breaker.
FAQ
Questions about the Legrand 407673 DX3 6000 A 1-Pole 32 A C-Curve MCB
Answers from our engineering team on installation, compatibility and integration.
01What is the Legrand 407673?
It is a DX3 6000 A single-pole thermal-magnetic miniature circuit breaker rated 32 A with C release curve. It is 17.8 mm wide, mounts on a 35 mm DIN rail and offers IP20 finger-safe terminals.
02What are the breaking capacities of 407673?
At 230 V the catalogue lists Icn 6 kA under EN 60898-1 and Icu 10 kA under IEC 60947-2. Under the DX3 datasheet the service breaking capacity Ics is 75 percent of Icu for this class.
03At what current does 407673 trip instantly?
A C-curve breaker trips magnetically between 5 and 10 times In under EN 60898-1, which means about 160 A to 320 A for a 32 A device. The thermal part follows a 1.13 In non-tripping and 1.45 In tripping characteristic.
04Can 407673 be used on a DC supply?
Yes, within the limits in the DX3 direct-current sheet. A one-module single-pole device is limited to 60 V DC maximum, with series connection of poles needed for higher DC voltages, and the magnetic trip rises by a factor of 1.4.
05Which wires does 407673 accept?
The terminals take multi-wire conductors of 1.5 to 25 mm² and solid-core conductors of 1.5 to 35 mm². Aluminium cable above 10 mm² needs the terminal accessory listed in the datasheet.