Brand:

ifm PN7094 Pressure Sensor, -1 to 10 bar, IO-Link

Description

ifm PN7094 Pressure Sensor, -1 to 10 bar, IO-Link

The ifm PN7094 is a pressure sensor with a four-digit display for compound ranges that cross zero: it measures from -1 bar (vacuum) up to 10 bar, which makes it a natural fit for suction lines, vacuum-assisted handling and low-pressure pneumatic or hydraulic circuits. It has two switching outputs, one of which can run in IO-Link mode, and a red/green display that changes colour to show whether the reading is inside the acceptable window. The process connection is a G 1/4 internal thread, and the process connection can be rotated for the best display orientation after installation.

Seven Star LLC supplies the PN7094 in Oman and the GCC as an independent supplier in Muscat. The type designation shown by the manufacturer for this article is PN-010-RER14-QFRKG/US/V, and the article number PN7094 is what you quote when ordering.

PN7094 technical specifications

The table lists the values published by the manufacturer for the PN7094. Where a parameter has several operating modes, the headline value is shown; the full parameter list is in the manufacturer documentation.

Parameter Specification
Manufacturer / part number ifm electronic / PN7094
Measuring range -1 to 10 bar / -14.5 to 145 psi / -0.1 to 1 MPa
Process connection threaded connection G 1/4 internal thread
Dimensions [mm] Ø 34 / L = 90.7
Measuring element ceramic-capacitive pressure measuring cell
Media liquids and gases
Medium temperature [°C] -25 to 80
Min. burst pressure 150 bar / 2175 psi / 15 MPa
Pressure rating 75 bar / 1087 psi / 7.5 MPa
Type of pressure relative pressure; vacuum
Operating voltage [V] 18 to 30 DC (to SELV/PELV)
Current consumption [mA] < 35
Output signal switching signal; IO-Link (configurable)
Electrical design PNP/NPN
Output function normally open / normally closed (parameterisable)
Permanent current rating of switching output DC [mA] 150 (200 ( to 60 °C) 250 ( to 40 °C))
Switching frequency DC [Hz] < 170
Switch point accuracy [% of the span] < ± 0.5
Repeatability [% of the span] < ± 0.1 (with temperature fluctuations < 10 K)
Long-term stability [% of the span] < ± 0.05 (per 6 months)
Response time [ms] < 3
Communication interface IO-Link
Ambient temperature [°C] -25 to 80
Protection IP 65; IP 67
Min. pressure cycles 100 million
Weight [g] 241.7
Materials stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts) stainless steel (316L/1.4404); ceramics; FKM
Connector 1 x M12; coding: A; Contacts: 4, gold-plated
MTTF [years] 260

How the PN7094 works

Inside the PN7094 a ceramic-capacitive measuring cell converts process pressure into a small change in capacitance. The electronics linearise that signal, compensate for temperature and compare the result with the switch points you have stored. The red/green four-digit display shows the live value in the unit you select, while two yellow LEDs mirror the state of the two outputs. Because the cell is ceramic and the wetted parts are limited to stainless steel, ceramic and FKM, the same sensor handles liquids and gases without an isolating diaphragm. One output can run in IO-Link mode, which lets a controller read the pressure as process data and push parameters back to the sensor after a replacement.

Where the PN7094 fits and related parts

The PN7094 belongs to the PN70 series of pressure sensors with display. Within that series, the PN7092 covers 0 to 100 bar with a 300 bar pressure rating for hydraulic duty, and the PN7097 covers 0 to 1 bar for very low pressure. The PN7094 sits in the middle and is the one to pick when vacuum must be seen on the same device as positive pressure. It can be connected directly to a PLC input as a switch, or to an IO-Link master port such as the master interfaces in the AL series for continuous pressure data.

Selection and ordering checklist for the PN7094

Work through the points below before you confirm the order, so that the PN7094 you receive is the one your machine or plant needs.

  • Check that the real pressure never exceeds the 75 bar pressure rating, and that spikes stay below it; the burst pressure is 150 bar
  • Confirm that vacuum down to -1 bar is part of the duty; if only positive pressure is used, consider a unipolar range
  • Match the G 1/4 internal thread to a fitting with a suitable seal, and check the tightening torque window
  • Verify that media are compatible with stainless steel 316L, ceramic and FKM
  • Decide whether you need IO-Link or only the switching outputs

The manufacturer lists this article under the type designation Pressure sensor with display, PN-010-RER14-QFRKG/US/ /V. The article number PN7094 is the reference to quote when ordering, and the type designation is useful for technicians who compare the label on an installed unit.

Installation, commissioning and maintenance

Fit the sensor with a suitable sealing washer or O-ring for the thread form and tighten within the torque window printed in the table; over-tightening a ceramic cell is a common cause of zero shift. Mount it so that the connector points downward or sideways, which keeps condensation from running into the M12 interface, and rotate the process connection to align the display before final tightening. During commissioning set the unit, then the switch points and hysteresis or window, and decide whether each output is normally open or normally closed. Check that the supply stays inside 18 to 30 V DC under load. For maintenance, a periodic zero check against atmosphere on a vented line and a look at the connector for moisture are normally enough. In pulsating systems such as piston pumps, a restrictor or damper protects the cell and steadies the reading.

On vacuum duty the sensor should be mounted so that condensate can drain away from the port, and the fitting should be leak-free, because even a small leak shows as a drifting vacuum value. The pressure-cycle rating of 100 million cycles is a design figure and suits frequently cycling circuits.

Typical applications in Oman and the GCC

In oil and gas and petrochemical plants the PN7094 is used for instrument-air headers, vacuum pump suction monitoring and lubrication circuits on skids. Power stations use it for seal-air and control-air supply, and desalination plants use it on vacuum and low-pressure sections of dosing and filtration skids. The wetted parts are stainless steel, ceramic and FKM, which copes with the humid and salty air common on the Gulf coast, and the IP65/IP67 rating helps against dust and wash-down in outdoor equipment.

Pressure instruments in the Gulf face heat on sun-exposed skids, fine dust and salty humidity. Stainless steel wetted parts, a sealed M12 connection and a conservative pressure margin are the three things that decide service life. Mount the sensor out of direct sun where possible and keep the connector pointing down.

PN7094 compared with related ifm types

The table places the PN7094 next to neighbouring types in the same application group, so you can see whether a sibling would suit the job better.

Part number Key characteristics Note
PN7094 -1 to 10 bar, G 1/4 internal, 2 outputs This page
PN7092 0 to 100 bar, G 1/4 internal, 2 outputs Related type
PN7097 0 to 1 bar, G 1/4 internal, 2 outputs Related type
PT5400 0 to 400 bar, G 1/4 external, 4-20 mA Related type
PX3224 0 to 100 psi, 1/4 NPT external, 4-20 mA Related type

Information to send with an RFQ for the PN7094

To prepare an accurate offer for the PN7094, please include the following with your enquiry:

  • Required pressure range and whether the process is gauge, vacuum or compound
  • Medium, temperature range and any pulsation or pressure spikes
  • Process thread and the sealing material you need
  • Connector or cordset requirements and the cable length
  • Quantity, delivery location and whether IO-Link master ports are available

Documents and quotation

No datasheet is attached to this page. Send us the part number PN7094 and we will confirm which documents are available, such as the datasheet and operating instructions, and for IO-Link devices the device description file.

Seven Star LLC is an independent supplier in Muscat serving Oman and the GCC and is not affiliated with the manufacturer; the name ifm is used only to identify the product. Prices are not shown on the page, so send the part number, the quantity and the delivery location to receive a quotation.

Other Models in the Ifm Pn70 Range

Seven Star LLC supplies models from the Ifm Pn70 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
ifm PN7094 Pressure Sensor, -1 to 10 bar, IO-LinkPressure InstrumentationYou are viewing this model
ifm PN7092 Pressure Sensor, 0 to 100 bar, IO-LinkPressure InstrumentationView details
ifm PN7097 Pressure Sensor, 0 to 1 bar, IO-LinkPressure InstrumentationView details
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ifm is a German family-owned maker of sensors and automation products, founded in Essen in October 1969 by Robert Buck and Gerd Marhofer. Its first products were inductive proximity sensors sold under the efector name. ifm is still headquartered in Essen, and the founders' sons, Martin Buck and Michael Marhofer, have led it since 2001.

Seven Star LLC lists ifm position, distance and pressure sensors and supplies them by exact article number to plants and machine builders in Oman and the wider Gulf region.

ifm company profile

Founded 1969, Essen, Germany
Founders Robert Buck and Gerd Marhofer
Headquarters Essen, Germany
Ownership Family-owned
Product families Inductive and capacitive proximity sensors, PN pressure sensors, O1D laser distance sensors, flow and level sensors, IO-Link masters

Milestones

  • 1969: ifm is founded in Essen.
  • 2001: The founders' sons take over management.

ifm sensors listed on this page

ifm identifies every device with a short article number, and that number is what we order against. Three are listed here:

  • O1D100: laser distance sensor for position and distance measurement
  • PN7093: pressure sensor with local display
  • NG5021: inductive proximity sensor with NAMUR output

Other ifm inductive sensors, pressure sensors and connection cables can be quoted on request when you send the article number.

ifm products we list

Family Examples
Inductive Proximity Sensors NG5021 Inductive NAMUR Proximity Sensor
Laser Distance, LiDAR & Radar Sensors O1D100 Laser Distance Sensor
Pressure Instrumentation PN7093 Pressure Sensor with Display

Ordering ifm sensors: what we need

Send the six-character article number printed on the housing (two letters and four digits, or similar). If the label is worn, a photo plus the thread size, sensing range, output type and connector style is enough for us to check the part against ifm documentation. For NAMUR sensors, tell us which isolating amplifier is in the loop. Buyers in the GCC who need a successor for a discontinued article can send the old number and we will check the replacement the manufacturer names.

Facts checked against ifm's own 50-year chronicle (ifm.com), October 2026.

FAQ

Questions about the ifm PN7094 Pressure Sensor, -1 to 10 bar, IO-Link

Answers from our engineering team on installation, compatibility and integration.

01What pressure range does the ifm PN7094 cover?
The PN7094 measures from -1 to 10 bar (-14.5 to 145 psi), so it covers both vacuum and positive pressure on one device.
02What is the process connection of the PN7094?
The PN7094 has a G 1/4 internal thread. The process connection can be rotated to align the display after installation.
03Does the PN7094 support IO-Link?
Yes. Two switching outputs are provided, and one of them can be configured for IO-Link communication, revision 1.1.
04What media can the PN7094 be used with?
It is specified for liquids and gases. The wetted parts are stainless steel (316L), ceramic and FKM, so check chemical compatibility for aggressive media.
05What is the overload limit of the PN7094?
The pressure rating is 75 bar and the minimum burst pressure is 150 bar, which gives good protection against pressure spikes in 10 bar systems.