- Automation & ControlView all 2,612 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Pneumatic Cylinders
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Legrand
Legrand 411189 DX3 4P 32 A C-Curve RCBO 30 mA AC
Description
411189: Legrand DX3 4-pole 32 A RCBO in 4 modules, 30 mA AC type
The Legrand 411189 is a DX3 6000 A four-pole RCBO rated 32 A, curve C, with 30 mA AC-type residual current protection. Unlike larger four-pole RCBOs, it occupies only four modules (71.2 mm). It works on 400 V AC at 50 Hz, and the page lists 6 kA breaking capacity under EN 61009 and under IEC 60947-2. Seven Star LLC supplies 411189 in Oman and the GCC as an independent supplier in Muscat.
The data sheet for this range states that the device gives simultaneous opening and closing of all poles through a trip-free mechanism, with positive contact indication. It protects people against direct and indirect contact, and installations against insulation faults, while also giving overload and short-circuit protection.
Reading the reference 411189
| Element | Value | Meaning |
|---|---|---|
| DX3 6000A 4-pole | Range | Compact 4-protected-pole RCBO with 6 kA capacity |
| 32 A, curve C | Overcurrent part | Magnetic trip between 5 and 10 x In, 160 to 320 A |
| 30 mA type AC | Residual part | Instantaneous trip on sinusoidal AC residual current |
| 4 modules | Width | 71.2 mm for four poles |
| Ref. 411189 | Catalogue number | Reference to quote |
Technical specifications for 411189
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Legrand / 411189 (DX3 RCBO 6000 A, 4 pole, 32 A, C, 30 mA, type AC) |
| Poles | 4 total, 4 protected, neutral switched concurrently |
| Rated current / curve | 32 A / C |
| Rated residual current | 30 mA, type AC |
| Rated voltage / frequency | 400 V AC, 50 Hz; 230/400 V and 240/415 V with standard tolerances; maximum 440 V |
| Breaking capacity | Icn 6 kA (EN 61009-1); 6 kA under IEC 60947-2 |
| Current limiting class | 1 per product page |
| Surge current capacity | 0.25 kA |
| Width / built-in depth | 4 modular spacings (71.2 mm) / 44 mm |
| Terminals (data sheet) | Cage terminals, depth 13 mm, torque 2.5 Nm recommended (1.2 to 3.5 Nm) |
| Protection / pollution | IP20 wired, pollution degree 2 |
| Supply | Top or bottom; wire prong busbar or HX3 plug busbar |
| Mounting | 35 mm DIN rail with two clamps, label holder, ON/OFF handle indication |
How 411189 protects a three-phase circuit
All four poles of 411189 are protected, and a residual transformer encloses the three phases and the neutral. If the current in the neutral and phases no longer adds up to zero by 30 mA or more, the relay trips and the device opens every pole together. The thermal element handles sustained overload at 32 A and the magnetic element handles short circuits at 160 to 320 A. A test button allows the installer to prove the residual function.
For a three-phase network without neutral, the data sheet gives a wiring instruction that connects the three phases in the arrow positions shown on the device. This flexibility is useful for motor circuits where no neutral is distributed. The data sheet also states that a device may be replaced in the middle of a busbar row without disconnecting neighbours.
Where 411189 fits and related parts
This RCBO is a compact way to protect individual three-phase circuits such as small pumps, welders, HVAC compressors and sub-panels up to 32 A. For higher ratings the 7-module 63 A model 411192 is available, while 2-pole 411161 serves single-phase final circuits. The data sheet for this four-pole range lists 10, 13, 16, 20, 25 and 32 A in B and C curves and AC, A and F types, so another letter combination may be better for loads with rectifiers or drives than the AC type of 411189.
Selection checklist for 411189
- Rated current: 32 A, within cable ampacity and thermal derating limits.
- Residual type: AC only; choose A or F for electronic loads.
- Sensitivity: 30 mA for personal protection; 300 mA or 1000 mA options exist in the range for fire protection.
- Fault level: 6 kA; check the prospective short-circuit current at the board.
- Space: four modules, a good fit for dense three-phase boards.
- Wiring: with a neutral, or three-wire as shown in the data sheet.
Installation, testing and maintenance of 411189
Fit the RCBO on the rail and connect it according to the diagram on the device; observe the neutral marking when a neutral is present. Tighten the cage terminals to about 2.5 Nm and keep the stripped length consistent with the data sheet. After energising, press the test button and confirm that all four poles open, then reset. Record 411189 in the circuit schedule with the date of the first test, and repeat the test at regular intervals. A trip with no cause after repeated resets points to a leakage fault that needs investigation.
Typical applications in Oman and the GCC
Individual three-phase circuits for pumps, fans and small machines in industrial units, desalination skids and building services panels are typical. Because the device is compact, it helps keep board size down, but the heat of several loaded devices side by side should be considered during design for Gulf summer conditions.
Information to send with an RFQ for 411189
- Reference 411189 and the quantity, including spares for panel maintenance.
- Rated current (32 A), curve (C), poles (4) and sensitivity (30 mA).
- Residual current type required and the nature of the load.
- Wiring with or without neutral, and board layout.
- Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
- Any documents you need with the quotation, such as a technical data sheet or a compliance statement.
Storage, handling and spares for the Legrand 411189
Keep Legrand 411189 units in their original packaging until they are mounted. Store them indoors in a dry, dust-free room, away from direct sun and condensation. Panel shops in Oman and the GCC often hold stock in warehouses that get very hot in summer, so check that storage temperature stays within the limits given in the manufacturer datasheet.
- Check the label and order code on every unit against the drawing before it goes into the panel.
- Use the correct tool and tightening torque for the terminals, as given in the instructions supplied with the product.
- Keep a small number of spare units for each rating used on site, so that a failed or damaged part can be replaced without waiting for a new shipment.
- Record the order code in the panel documentation and the as-built drawings, so that maintenance teams can reorder the same part later.
When you plan spares for a project, group the Legrand 411189 with the other parts of the same panel in one RFQ. This keeps delivery dates aligned and makes it easier to confirm stock for the whole bill of materials at once.
Documents and quotation
The Legrand technical data sheet that covers 411189 is attached on this page. It gives the range table, dimensions, curves and accessories, so check its notes against your design before you order.
To request a quotation, send reference 411189, the quantity and your delivery location. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer; we will confirm availability and lead time for your order.
See also: Legrand DX3 C32 4-Pole Miniature Circuit Breaker.
Other Models in the Legrand Dx3 Rcbo Range
Seven Star LLC supplies models from the Legrand Dx3 Rcbo range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Legrand 411192 DX3 4P 63 A C-Curve RCBO 30 mA AC | Circuit Breakers | View details |
| Legrand 411161 DX3 2P 32 A C-Curve RCBO 30 mA AC | Circuit Breakers | View details |
| Legrand 411189 DX3 4P 32 A C-Curve RCBO 30 mA AC | Circuit Breakers | You are viewing this model |
Datasheets & Documents
- Datasheet Legrand 411189 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Legrand is a French maker of electrical and digital building infrastructure, headquartered in Limoges. Its roots lie in a nineteenth-century porcelain workshop in Limoges, and it grew into one of the largest makers of wiring devices, circuit protection, cable management and data centre products. Legrand is listed on Euronext Paris and sells under brands including Legrand, Bticino and Cablofil.
Seven Star LLC, an independent supplier in Muscat, lists Legrand circuit breakers for electrical contractors and panel builders in Oman and the GCC, at present a DX3 4-pole miniature circuit breaker rated C32.
Legrand company profile
| Headquarters | Limoges, France |
|---|---|
| Listing | Euronext Paris |
| Brands | Legrand, Bticino, Cablofil, Zucchini |
| Product families | DX3 miniature circuit breakers and RCDs, wiring devices, cable trays, busbar trunking, UPS |
Legrand DX3 circuit breakers
DX3 is the Legrand family of modular protection devices for DIN rail mounting. The item on our site is a 4-pole MCB with a C tripping curve and a 32 A rated current. Three things besides the pole count define a breaker of this kind: the curve, the rated current and the breaking capacity printed on the front. Legrand catalogs DX3 breakers in 6000 A and 10000 A versions under separate references.
Ordering Legrand breakers: what we need
Send the Legrand catalog number printed on the device, a six-digit reference, where it is legible. Otherwise give the number of poles, the curve, the rated current, the breaking capacity and the voltage. Mention any auxiliary contact or residual current add-on module fitted beside the breaker, and the board type.
Facts checked against Legrand's published corporate information, October 2026.
Browse Legrand products by category: Circuit Breaker.
FAQ
Questions about the Legrand 411189 DX3 4P 32 A C-Curve RCBO 30 mA AC
Answers from our engineering team on installation, compatibility and integration.
01What is 411189?
It is a Legrand DX3 four-pole RCBO rated 32 A with a C curve and 30 mA AC-type residual current protection, four modules wide, for 400 V AC circuits.
02How wide is 411189 compared with 411192?
411189 is four modules (71.2 mm) wide, while the 63 A four-pole RCBO 411192 occupies seven modules (124.6 mm).
03What breaking capacity does 411189 have?
The product page lists 6 kA under EN 61009 and 6 kA under IEC 60947-2, and the data sheet gives Icn 6000 A certified to EN/IEC 61009-1.
04Can 411189 be used without a neutral?
Yes. The data sheet describes a wiring arrangement for 400 V three-phase networks without neutral, connecting the three phases as shown by the arrows on the device.
05Which residual types exist in the same family as 411189?
The data sheet lists AC, A and F types in 30, 300 and 1000 mA, so replacements can follow the load type even though this reference is AC with 30 mA.


















Reviews