Brand:

TSI Q-Trak 7575 Indoor Air Quality Monitor with Plug-in Probes

Description

An IAQ logger that changes sensors by changing the probe

The TSI Q-Trak 7575 is an indoor air quality monitor built on a probe-swapping design. The meter body holds the electronics, logger, barometric sensor and two thermocouple inputs, and TSI plug-in probes supply the measuring element: CO2 with temperature and humidity (980), the same plus carbon monoxide (982), VOC probes (984 to 987) or velocity probes.

The 56,035-point memory means it can sit in a plant room or office for several weeks of trend logging. The manual supports two variants, 7575-X with Bluetooth and 7575-X-NB without. See the wider Portable Test & Measurement group for companion tools.

Capabilities listed in the manual

  • Plug-in probe system with D-shaped mini-DIN connector; two K-alloy thermocouple ports reading TC1, TC2 or TC1-TC2.
  • Logging modes Manual, Auto-save, Cont-key, Cont-time, and Programs 1 and 2 configured with TrakPro software; up to 38.9 days at 1-minute intervals.
  • Applications for Draft Rate, Heat Flow, Turbulence and % Outside Air (0 to 100 %, 0.1 % resolution).
  • Zero CO routine for the 982 probe, and field calibration menu entries for temperature, velocity, RH, barometric pressure, CO2, CO and VOC.

Technical specification

Sensors (with the stated probe)

Parameter Specification
Models covered 7575-X and 7575-X-NB (no differential pressure sensor)
CO2 0 to 5000 ppm; +/-3 % of reading or +/-50 ppm (at 77 F / 25 C, add +/-0.2 %/F away from calibrated temperature); 1 ppm; NDIR
CO (probe 982) 0 to 500 ppm; +/-3 % of reading or 3 ppm, whichever is greater; 0.1 ppm; response under 60 s to 90 %; electrochemical
Temperature 14 to 140 F (-10 to 60 C); +/-1.0 F (+/-0.5 C); 0.1 F; thermistor; 30 s to 90 % at 2 m/s
Relative humidity 5 to 95 % RH; +/-3 % RH including 1 % hysteresis; 0.1 % RH; thin-film capacitive; 20 s to 63 %
% Outside Air 0 to 100 %; resolution 0.1 %
Barometric pressure 20.36 to 36.648 in. Hg (517.15 to 930.87 mm Hg); +/-2 % of reading

Logging, physical and power

Parameter Specification
Data storage Up to 56,035 data points with four measured parameters enabled; 38.9 days at 1-minute intervals; 26,500+ samples, 100 test IDs
Logging interval / time constant 1 second to 1 hour / 1, 5, 10, 20 or 30 s
Operating temperature (electronics) 40 to 113 F (5 to 45 C)
Storage temperature -4 to 146 F (-20 to 60 C)
Operating conditions Altitude up to 4000 m; up to 80 % RH non-condensing; pollution degree 1 (IEC 664); transient overvoltage category II
Meter dimensions 3.8 x 8.3 x 2.1 in. (9.7 x 21.1 x 5.3 cm)
Weight 0.8 lb (0.36 kg) with batteries
Probe 982 dimensions Length 7.0 in. (17.8 cm); tip diameter 0.75 in. (1.9 cm)
Power Four AA alkaline or rechargeable cells (DIP switch for NiMH), or AC adapter p/n 801761, 90 to 240 VAC 50/60 Hz in, 9 VDC 2 A out
Wireless Classic Bluetooth v2.0, +4 dBm maximum at 2.4 to 2.5 GHz (7575-X)
Supplied Carrying case, instrument, USB cable, AC adapter

Probe choice for the 7575

Probes are ordered separately. For ventilation checks pick CO2, temperature and humidity (980) or add CO (982); for solvent and off-gassing surveys pick a VOC probe: 984 low (ppb) or 985 high (ppm) concentration, and 986 or 987 which add CO2, temperature and humidity. Thermoanemometer probes (960, 962, 964, 966), the 995 rotating vane and thermocouple probes 792 and 794 are also listed. Specifications for each probe sit in its own manual, which is not included in this document.

Operating notes

Align the D-shaped overmolding with the connector, then power up; if a probe is plugged in after power-on the manual says to restart the monitor. Warm up for five minutes before Zero CO, and run it where there is no combustion that could affect zeroing.

Keypad lock protects settings during unattended logging. Set DIP switch 1 for NiMH before charging; do not charge alkaline cells. Program 1 and 2 logging schedules are set through TrakPro, and the 7575-X pairs with the Model 8934 printer only when the PIN code is 0000.

IAQ surveys in Gulf buildings

CO2 trend logs over a working day show whether outside-air dampers are delivering design ventilation in offices and schools, while a CO probe helps screen car parks, kitchens and plant rooms. The electronics are rated 5 to 45 C, so leave the monitor in conditioned space for long logging sessions rather than on an exposed rooftop.

Printer, software and probes

The manual names the Model 8934 wireless printer, TrakPro data analysis software, the AC adapter p/n 801761, and application notes TSI-124, TSI-138, TSI-141, TSI-142, TSI-146 and TSI-150. All plug-in probes in Appendix B must be ordered with the monitor.

Selection and installation notes

Handheld air and environment meters are selected from the quantity measured, the range and the accuracy needed. Let the probe settle in the air stream, take readings at the points and the number the test method requires, keep the sensors clean, check the battery before a survey and keep the calibration current according to your quality system. Note the conditions and the probe position with every reading so the survey can be repeated.

Information needed for a quotation

Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.

Documents and supply information

The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.

Frequently asked questions

Which probe gives CO as well as CO2? The 982 IAQ probe, which also measures temperature and humidity; CO range is 0 to 500 ppm.

How long can it log? The manual gives 56,035 data points with four parameters enabled, or 38.9 days at 1-minute intervals.

What is the difference between 7575-X and 7575-X-NB? The -X has Bluetooth for the optional printer; the -X-NB does not.

Does it measure differential pressure? No. Both listed variants have no differential pressure sensor.

Is Seven Star LLC a TSI distributor? No, we are not a TSI distributor. Seven Star LLC is an independent Muscat supplier that sources genuine instruments.

Documents and quotation

The attached file is the TSI operation and service manual (P/N 6004850 Rev J, December 2024). Ask for a quotation and confirm variant and accessories beforehand; prices are not published here.

Datasheets & Documents
  • PDF Datasheet TSI Q-Trak Model 7575 Operation and Service Manual (P/N 6004850 Rev J) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

TSI Incorporated is a measurement instrument manufacturer founded in 1961 and based in Shoreview, Minnesota. Its catalogue is built around airflow, aerosol and indoor air quality measurement.

Seven Star LLC is an independent supplier in Muscat. We list TSI instruments for HVAC, cleanroom and environmental users in Oman and the GCC.

TSI product series

Ventilation instruments include the VelociCalc 9545 air velocity meter, the VelociCalc 9565 multi-function ventilation meter, the VelociCalc 5725 rotating vane anemometer, the DP-Calc 5825 micromanometer for duct and filter pressure and the AccuBalance 8380 capture hood for measuring airflow at diffusers and grilles.

Air quality and aerosol instruments include the Q-Trak 7575 indoor air quality monitor with plug-in probes, the IAQ-Calc 7525 for CO2, temperature and humidity, the P-Trak 8525 ultrafine particle counter and the DustTrak II 8530 and DustTrak DRX 8533 desktop aerosol monitors for PM1, PM2.5 and PM10.

Where TSI instruments are used

HVAC testing and balancing, cleanroom and laboratory ventilation checks, fume hood testing, indoor air quality surveys and dust monitoring on construction, industrial and plant sites.

Ordering TSI instruments: what we need

Send the model, the probes and accessories required, the software and calibration certificate needs, and for dust monitors the measurement mode and inlet. We confirm the configuration against the official manual before quoting.

Frequently Asked Questions

Which probe gives CO as well as CO2?
The 982 IAQ probe, which also measures temperature and humidity; CO range is 0 to 500 ppm.
How long can it log?
The manual gives 56,035 data points with four parameters enabled, or 38.9 days at 1-minute intervals.
What is the difference between 7575-X and 7575-X-NB?
The -X has Bluetooth for the optional printer; the -X-NB does not.
Does it measure differential pressure?
No. Both listed variants have no differential pressure sensor.
Is Seven Star LLC a TSI distributor?
No, we are not a TSI distributor. Seven Star LLC is an independent Muscat supplier that sources genuine instruments.