Brand: Rheonik
Rheonik RHM100 Coriolis Mass Flow Meter Sensor 12000 kg/min
Description
Large-bore Coriolis metering for terminals and transfer
The Rheonik RHM100 is Rheonik’s high flow Coriolis sensor for terminal transfer and viscous fluids. A typical range of 150 to 12000 kg/min is equivalent to roughly 9 to 720 tonnes per hour (derived), which makes it a candidate for ship, barge, rail car and truck loading where direct mass metering replaces tank gauging. Operation down to -196 C also covers cold hydrocarbons.
The sensor is paired with a Rheonik RHE transmitter, either integral or remote.
Highlights
- Pressure ratings up to 237 bar (3437 psi) and temperatures from -196 to +210 C.
- Mass flow uncertainty down to 0.1%; repeatability down to 0.05%.
- Measurement updates of 4 kHz with RHE40 series transmitters.
- Compact body with minimal pipeline footprint and AnyPipeFit custom connections.
Technical specification
| Parameter | Specification |
|---|---|
| Nominal flow Qnom | 10000 kg/min (26456 lb/min) |
| Maximum flow Qmax | 12000 kg/min (26455.47 lb/min) |
| Typical minimum flow Qmin | 150 kg/min (330 lb/min) |
| Pressure drop at Qnom | About 0.5 bar (7.3 psi) on water, parallel tube |
| Zero point stability | 1.5 kg/min standard; 1.35 kg/min premium |
| Fluid temperature | -196 to +210 C (-320 to +410 F) |
| Wetted materials | Tubes SS 316Ti, Alloy C22 or Super Duplex; seals FKM, FFKM, FVMQ, EPDM, HNBR |
| Housing and ingress | IP66 (N1, NA ranges); IP65 (E2, E3, H4 ranges); coated aluminum or SS 316L terminal box |
| Face to face length | 900 mm (35.43 in) for the 8 in and 10 in flange list |
| Weight | About 520 kg with 8 in 150# flanges; about 750 kg gross, packed in an ISPM 15 wooden crate |
Pressure by tube material
At 50 C the listed limits are 73 bar for M0 SS 316Ti, 94 bar for H0 Alloy C22 and 237 bar for D1 Super Duplex. At 350 C the M0 tube is rated 48 bar (derived from 696 psi). The lowest-rated of tube, block and process connection governs, so flange class matters on the largest sizes.
Ordering notes
Flange options include ANSI 8 in 150#, 300#, 600#, ANSI 10 in 150#, 300# and 600#, 8 in 900# and 1500# RTJ and DIN DN200 PN16, PN40 and PN100, all at 900 mm face to face. Specify the temperature range, tube material, calibration (A, B, G or 1) and terminal box. The datasheet notes that the tolerance on face-to-face length is plus or minus 2 mm.
Order code and housing options
Temperature range codes for this sensor are N1 (-20 to +120 C), NA (-50 to +120 C), EM (-20 to +160 C), E2 (-50 to +210 C) and E3 (-196 to +50 C); the order code table does not list a 350 C range, although the housing note mentions H4. Ask for confirmation if you need that range. Housing choices include a standard stainless steel body, a special SS 316 body, and versions with a rupture disc with or without a G 3/4 in male drain connection. Because E3 spans -196 to +50 C, hot service needs a different range code; the datasheet recommends insulation for the E2, E3 and H4 ranges. The datasheet also lists PED compliance, a low-flow calibration at 0.10% over four points and material certificates to EN 10204 3.1.
Installation planning
At this size the sensor is a lifting and supporting task; plan crane access and pipe supports before delivery, using the 750 kg gross weight in the datasheet as a basis. Because pressure drop rises with viscosity, verify the pump head for viscous crude or fuel oil duty.
Turn-down in practice
The calibration codes A, B and G quote 0.20%, 0.15% and 0.10% uncertainty. Using the datasheet rule that uncertainty equals the calibration figure only when flow is at least the zero point stability divided by the uncertainty, a standard sensor (1.5 kg/min) holds 0.20% above about 750 kg/min, and a premium sensor (1.35 kg/min) holds 0.10% above about 1350 kg/min (both derived). Below those flows the zero point term dominates, so choose the premium option if long periods of low-rate loading are expected.
Mounting and electrical options
The JM coated aluminum box measures 125 x 80 x 57 mm and the SM stainless steel box 100 x 100 x 61 mm, both with an M20 x 1.5 cable entry. The datasheet shows the sensor housing at IP66 for the standard temperature ranges, and a lower IP65 rating applies for the extended ranges. Maximum cable length to a remote RHE transmitter is 100 m (330 ft). The shipping crate follows ISPM 15, which matters for customs and handling on export routes.
Use in Oman and the GCC
Port terminals, export loading jetties, refinery transfer lines and tank farms use large Coriolis meters where custody or allocation accuracy is required. Confirm the applicable approval for your use before ordering.
Selection and installation notes
A Coriolis sensor is sized from the flow range and the pressure drop, so confirm the fluid, density, viscosity, operating pressure and temperature before ordering. Mount the sensor on a rigid support without stressing the pipe, keep it full of liquid, avoid mounting where vibration from pumps reaches it and follow the orientation and drain advice in the manual. Zero the meter with no flow once the line is full, record the settings, and choose the electronics and output type that match the control system.
Information needed for a quotation
Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Related items and quotation
See flow and process measurement for related equipment. Send the product, flow rate, line size and pressure class and we will prepare a quotation; confirm the full order code before ordering.
Datasheets & Documents
- Datasheet Rheonik RHM100 Coriolis mass flow meter datasheet (V02.00) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rheonik designs and manufactures Coriolis mass flow meters and the transmitters that drive them, with its head office in Odelzhausen, Germany, where it was founded in 1986. Its meters measure mass flow, density and temperature directly, independent of fluid properties.
Seven Star LLC is an independent supplier in Muscat. We list Rheonik sensors and transmitters with their official datasheets for oil and gas, petrochemical, chemical and filling applications in Oman and the GCC.
Rheonik product series
RHM sensors on this site cover a wide range of sizes: the RHM06 for about 36 kg/min, the RHM20 for 480 kg/min, the RHM40 for 1500 kg/min, the RHM100 for 12,000 kg/min and the RHM160 for 30,000 kg/min. Tube materials, pressure ratings and process connections are chosen through the order code.
RHE transmitters include the RHE21 Ex d field mount transmitter, the RHE42 all-digital field transmitter, the RHE28 universal mount transmitter and the compact RHE26 and RHE46 units for panel or DIN rail mounting.
Where Rheonik meters are used
Custody transfer and loading of hydrocarbons, chemical injection and dosing, high-pressure gas and hydrogen measurement, batching and filling, and measurement of viscous or hot fluids.
Ordering Rheonik meters: what we need
Give the fluid, flow range, line pressure and temperature, process connection and hazardous area class. Sensor and transmitter approvals must match, so we confirm the full order code for both before ordering.
Browse Rheonik products by category: Flowmeters.
Related products
Frequently Asked Questions
Nominal flow is 10000 kg/min, maximum 12000 kg/min and typical minimum 150 kg/min.
Rheonik lists terminal transfer, viscous fluids, and barge, ship, rail car and truck filling.
A sensor with 8 in 150# flanges weighs about 520 kg (1146 lb) and has a face-to-face length of 900 mm.
Up to 237 bar (3437 psi) with Super Duplex D1 tubes and fluid temperatures from -196 C to +210 C.
IP66 for the N1 and NA temperature ranges and IP65 for E2, E3 and H4, per the datasheet housing table.