Automated pressure generation for the bench and the plant

The Additel ADT761A is a self-contained automatic pressure calibrator: a built-in electric pump generates the pressure, a controller holds it to 0.003% FS and a 7 inch touchscreen drives the calibration. You enter the set point, the calibrator reaches it and the reading is recorded, which removes the hand pumping and valve juggling of a manual comparison. It is portable enough for the field at about 7.95 kg and accurate enough for a working standard in a laboratory.

It improves on the first-generation 761 with a higher 1,500 psi range, removable internal modules, faster pressure build-up, the ability to read two external modules, a touchscreen with Wi-Fi, LAN, Bluetooth and Ethernet, and double the battery life, as described in the datasheet.

What distinguishes the 761A series

  • Six configurations: LLP, D, 500, 1K, 1.5K and BP, each with its own high-range and selectable low-range module.
  • Two removable internal modules give automatic multi-range selection for better accuracy at low points.
  • Full HART communicator, HART and Profibus PA communication, data logging and task management.
  • Electrical measurement and sourcing (current, voltage, 24 V loop power) for transmitter and switch calibration.
  • Patented electric pump technology.

Technical specification

Parameter Specification
Configurations 761A-LLP, -D, -500, -1K, -1.5K, -BP
Maximum range LLP 30 inH2O; D 35 psi; 500 psig; 1,000 psig; 1,500 psi (100 bar.g); BP 1,200 hPa
Minimum range Vacuum: -30 inH2O, -13.5 psi, -13 psi (gauge models); BP 100 hPa
Accuracy (1 year) LLP 0.05% FS; D 0.02% FS; 500, 1K and 1.5K 0.01% or 0.02% FS; BP 0.01% FS
Stability 0.003% FS or 0.05 Pa (LLP); 0.02 hPa on BP
Response time and over-range Typically 40 s or less; 110% over-range indication
Pressure type LLP and D: differential, gauge; 500 to 1.5K: gauge, absolute; BP: absolute
mA measure +/-25 mA and +/-50 mA, 0.1 uA, 0.008% RD + 1.0 uA / 2.0 uA
V measure +/-300 mV, 5 V, 12 V, 30 V auto-ranging, 0.008% RD + 6 uV to 600 uV
mA source 0 to 2.5 mA and 2.5 to 25 mA, 0.008% RD + 0.2 uA / 1.0 uA, 20 mA at 1 kohm
V source and power 0 to 16 V (0.008% RD + 500 uV); 24 V loop supply 50 mA; 16 to 30 V power source 70 mA
Switch test Mechanical, NPN and PNP switches; response under 10 ms
Display and interface 7 in 800 x 480 colour touchscreen and keypad
Communication USB, LAN, Bluetooth, Wi-Fi and Ethernet
Enclosure IP31
Battery and power Li-ion, typically 8 h, recharge under 4 h; 110/220 V adapter
Size and weight 299 x 193 x 192 mm (11.77 x 7.60 x 7.56 in); under 7.95 kg (17.52 lb)
Storage and logging Over 8 GB; up to 1,000,000 readings; up to 1,000 tasks
Environment 0 to 50 C operating and compensated; storage -20 to 60 C; under 90% RH
Vibration, shock and pump 4 g (20 to 2,000 Hz); 8 g and 1 m drop; pump life over 1,000,000 cycles
Certificate and warranty ISO 17025 accredited, NIST-traceable data; CE; 18 months

Choosing a model and modules

Each model ships with a fixed high-range module (DP30 for LLP, CP35 for D, CP500, CP1K or CP1.5K) plus a low-range module selected from the ADT155 table. The order code ADT761A-1.5K-02-CP35-PSI-N shows the pattern: series and range, accuracy, low-range module, unit and the manifold port (N, N2, B, B2 or M). Pick a low module around 5 to 10% of your typical test pressure so that the 0.01% or 0.02% FS span is as small as possible. The 0.01% FS option is not offered on the 761A-D, and absolute mode adds 55 Pa uncertainty from the barometer on the 500, 1K and 1.5K models.

Operation and care

The user manual lists several rules. Do not shake, drop or bump the calibrator in use, dry it out thoroughly if condensation has formed, and never point the vent port at the operator during venting. Do not apply more than 30 V between any two electrical jacks, other than the voltage measurement jacks, and bring system pressure back to atmosphere before switching off. Hoses and filters, pneumatic and hydraulic, should be replaced after about 10 years or at the first sign of wear.

Two port notes help stability. Keep the REF port open when calibrating gauge-pressure instruments, and connect it to the reference port of the unit under test for differential instruments. The manual says a control volume larger than about 100 cc at the output port affects pressure stability. The case is IP31 and the operating range is 0 to 50 C.

Where the 761A is used in Oman and the GCC

Metrology rooms at oil and gas operators, power utilities and desalination plants use automatic calibrators to verify pressure transmitters, switches and gauges in volume, and the task feature records as-found and as-left data. Field teams can bring the 761A to a compressor station to calibrate HART transmitters in place with the built-in communicator.

Selection and installation notes

Calibration equipment should be set up before it is relied on. Check the range and connections against the devices you will test, allow the instrument to warm up and stabilise, keep the fittings and tubing clean and use the correct adapters and seals. Keep the calibration certificate on file, plan the re-calibration interval according to your quality system, charge and store the battery as the manual describes and protect the case from impact when it is carried to site.

Information needed for a quotation

Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.

Documents and supply information

The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.

Accessories and related items

  • Included: ADT111-X-KIT external pressure manifold (not LLP), 9818 power adapter, 9725 Li-ion battery and 9240A DP gauge holder with an 80 ml chamber (LLP).
  • Optional: ADT161 digital pressure modules, ADT155 internal modules and the HART communication manual.
  • Related Additel products: ADT760A (handheld to 375 psi) and ADT762 (hydraulic to 15,000 psi).

Datasheet and quotation

The manufacturer datasheet is attached. Share your pressure range, accuracy target and HART requirement and our team will prepare a quote. Other instruments are listed under portable test and measurement. Please confirm the exact configuration before ordering.

Datasheets & Documents
  • PDF Datasheet Additel 761A series automated pressure calibrators datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Additel is an American manufacturer of pressure and temperature calibration equipment, headquartered in Brea, California, where it also runs an NVLAP-accredited calibration laboratory. Its range covers automated pressure calibrators and controllers, documenting process calibrators, digital pressure gauges, test pumps and dry well calibrators. Additel has offices in Utah, Beijing and Odense, Denmark, and its products are used in more than 100 countries.

Seven Star LLC is an independent supplier in Muscat. We list Additel instruments with their official datasheets for instrument and calibration teams in oil and gas, power, water and manufacturing in Oman and the GCC.

Additel company profile

Headquarters Brea, California, USA
Calibration laboratory NVLAP-accredited, Brea
Other offices Pleasant Grove (Utah), Beijing and Odense (Denmark)
Reach Products used in more than 100 countries
Product families ADT760A and ADT761A automatic handheld pressure calibrators, ADT762 hydraulic calibrator, ADT226 documenting process calibrator, ADT681A and ADT601Ex digital pressure gauges, ADT875 dry well calibrators, pressure test pumps

Additel product series

Pressure calibration equipment includes the ADT760A and 760S automatic handheld pressure calibrators, the ADT761A portable automatic calibrator, the ADT762 automated hydraulic calibrator and the ADT927 hydraulic test pump for 700 bar. Digital pressure gauges include the ADT681A wireless gauge with accuracy up to 0.01% of full scale and the ADT601Ex intrinsically safe gauge.

The ADT226 is a multifunction documenting process calibrator, and the ADT295 communicates with HART, Foundation Fieldbus and Profibus PA devices. Temperature calibration is covered by the ADT875 dry well calibrators and the ADT878 reference dry well calibrators.

Where Additel instruments are used

Field calibration of pressure and temperature transmitters, gauges, switches and RTDs, loop checks and documented calibration for quality audits, and calibration labs in plants and service companies.

Additel products we list

Family Examples
Portable Test & Measurement ADT226 Multifunction Documenting Process…, ADT760A / 760S Automatic Handheld Pressu…, ADT761A Portable Automatic Pressure Cali…, ADT762 Automated Hydraulic Pressure Cali…
Pressure Instrumentation ADT601Ex Intrinsically Safe Digital Pres…, ADT681A Wireless Digital Pressure Gauge
Temperature Instrumentation ADT875 Series Dry Well Temperature Calib…

Ordering Additel instruments: what we need

Send the model and pressure range, the medium (gas, oil or water), accuracy class and whether results must be documented. For dry wells give the temperature range, stability and insert size. We confirm the exact model code before ordering.

Facts checked against Additel's own catalogue and calibration services brochure, October 2026.

Frequently Asked Questions

What pressure range does the ADT761A cover?
Up to 1,500 psi (100 bar.g) in the 1.5K model, with 500 psi, 1,000 psi, differential LLP and D and barometric BP versions also listed in the datasheet. The ranges start at vacuum on the gauge models.
How accurate is the ADT761A?
Precision models reach 0.01% FS with 0.003% FS control stability. The LLP is 0.05% FS and the D model 0.02% FS, quoted as one-year accuracy on the span of the module.
Does the ADT761A have a HART communicator?
Yes. The datasheet lists a full HART field communicator and HART and Profibus PA communication, with DD files updated periodically.
Can it measure external pressure modules?
It can read two external Additel 161 series digital pressure modules, from -15 psi to 60,000 psi, in addition to its two removable internal modules.
What documentation does the calibrator include?
It is supplied with an ISO 17025 accredited calibration certificate with NIST-traceable data, and supports task documentation for up to 1,000 tasks stored with data.