Brand: Lovato Electric
Lovato RF380650 4-6.5 A Thermal Overload Relay
Description
Thermal overload protection for motors drawing 4-6.5 A
A motor needing overload protection in the 4-6.5 A band can use the RF380650, a thermal relay of the Lovato Electric RF38 family with phase-failure detection and a trip indicator.
Tripping class is 10A, the reset mode is manual or automatic, and the auxiliary contact block provides 1 NO and 1 NC for the control circuit. Insulation voltage is 690 V.
Technical specifications
| Parameter | Specification |
|---|---|
| Order code | RF380650 |
| Product type designation | RF38 |
| Product designation | Motor protection relay |
| Number of poles | 3 |
| Pollution degree | 3 |
| Frontal IP degree | IP20 |
| Type of release | Thermal |
| gG (IEC) | 16 A |
| aM (IEC) | 8 A |
| RK5 (UL) | 25 A |
| Functions and protections provided | Phase failure detection |
| Reset mode | Manual or automatic |
| Rated insulation voltage Ui IEC/EN | 690 V |
| Rated impulse withstand voltage Uimp | 6 kV |
| Rated operational voltage | 690 V |
| Operational frequency (min) | 0 Hz |
| Operational frequency (max) | 400 Hz |
| Operational current min | 4 A |
| Operational current max | 6.5 A |
| Tripping class | 10A |
| Test Button | Yes |
| Trip indicator | yes |
| Terminals type | screw and washer |
| Terminals screw | M4 |
| Terminals width | 12.6 mm |
| Terminals tool | Phillips 2 |
| Auxiliary contacts, NO | 1 |
| Auxiliary contacts, NC | 1 |
| Auxiliary Rated insulation voltage Ui IEC/EN | 690 V |
| Auxiliary Rated impulse withstand voltage Uimp | 6 kV |
| Auxiliary Rated operational voltage | 690 V |
| Auxiliary circuit type | screw and washer |
| Auxiliary circuit screw | M3.5 |
| Auxiliary circuit width | 8 mm |
| Auxiliary circuit tool | Phillips 2 |
| Operating temperature (min) | -25 °C |
| Operating temperature (max) | 60 °C |
| Storage temperature (min) | -50 °C |
| Storage temperature (max) | 70 °C |
| Compensation temperature (min) | -20 °C |
| Compensation temperature (max) | 60 °C |
| Max altitude | 3000 m |
| Operating position, normal | Vertical plan |
| Operating position, allowable | ±30° |
| Fixing | Direct mounting on BF09- BF38- |
| Weight | 160 g |
Choosing the setting range
The correct relay is the one whose 4-6.5 A range contains the nameplate current with some margin to adjust either way. The tripping class (10A) decides how long a starting overload is tolerated.
Short-circuit protection is separate: the datasheet quotes 16 A gG and 8 A aM as maximum fuse sizes for this relay.
Mounting and use
Typical use is the overload protection leg of a direct-on-line starter for pumps, fans and conveyors. The NC auxiliary contact opens the contactor coil circuit on a trip and the NO contact can drive an alarm.
Terminals are screw and washer. Operating and storage temperature limits are in the table; if the relay sits in a hotter place than the motor, set the dial with that in mind.
For panel design and commissioning, the practical figures to keep at hand are: terminals type screw and washer; terminals screw M4; terminals width 12.6 mm; terminals tool Phillips 2; auxiliary circuit type screw and washer; auxiliary circuit screw M3.5; auxiliary circuit width 8 mm; auxiliary circuit tool Phillips 2; operating temperature (min) -25 °C; operating temperature (max) 60 °C; storage temperature (min) -50 °C; storage temperature (max) 70 °C; max altitude 3000 m; operating position, normal Vertical plan. These come straight from the datasheet and are repeated here so that the key installation limits are visible without opening the PDF.
Documents and quotation
The figures above are those printed in the manufacturer’s datasheet for RF380650, supplied here as an attached English PDF from the Lovato catalogue. Before ordering, confirm the motor full-load current, the matching contactor and whether a manual or automatic reset is wanted; datasheet values can be revised by the manufacturer. For related parts browse contactors & overload relays. Send the order code RF380650, the quantity and the delivery location through the quotation form and Seven Star LLC, an independent supplier in Muscat, will reply with availability.
Datasheets & Documents
- Datasheet Lovato Electric RF380650 datasheet (EN, catalogue export) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Lovato Electric is the Italian manufacturer of low-voltage electrical components for industrial automation and power distribution: contactors, motor protection circuit breakers, soft starters, variable speed drives, power factor controllers, transfer switch and generator controllers, and energy meters. It was founded in Bergamo in 1922 and has been run by the same family for four generations. Its headquarters is in Gorle, near Bergamo, and it celebrated its centenary in 2022.
Seven Star LLC is an independent supplier in Muscat. We list Lovato motor control, drives and power management products, and supply them to panel builders, contractors and maintenance teams in Oman and the GCC by order code.
Lovato Electric at a glance
| Established | 1922, Bergamo, Italy |
|---|---|
| Headquarters | Gorle (Bergamo), Italy |
| Ownership | Private, family-run for four generations |
| Product families | Contactors and relays, motor protection circuit breakers, motor starters, soft starters, variable speed drives, power factor controllers, ATS and gen-set controllers, multimeters and energy meters, micro PLCs |
Lovato products we list
| Family | Models | Typical use |
|---|---|---|
| Contactors | BF0910A230, BF1810A230, BF2510A230, BF2600A230, BF09T4A230 4-pole, BFS0923A024, 11BG0910A230 mini, 11BGR0901A048 reversing | Switching motors, heaters, lighting and capacitor banks |
| Motor protection and starters | SM1P0650, SM1P1000, SM1P3200, M1P enclosed DOL starter, ME024FD024, ME070RSD024, 31L48 time relay | Short-circuit and overload protection and direct starting of motors |
| Soft starters | ADXL0030600, ADXL0085600, ADXL0135600, ADXT0034, ADXT0084, ADXT0139 | Reducing starting current and mechanical shock on pumps, fans and compressors |
| Variable speed drives | VLA1, VLB1, VLB3 0.75 kW, VLB3 2.2 kW, VLB3 5.5 kW, VLB3 22 kW, VT1 | Speed control of pumps, fans and conveyors to save energy |
| Power management and control | DCRG8, DCRL8 PF controllers, ATL600 ATS controller, RGK600 gen-set controller, DMG200 multimeter, DMED300T2 energy meter, LRD20 micro PLC | Power factor correction, mains/generator changeover and energy monitoring |
Lovato order codes describe the product. On a contactor such as BF0910A230, "BF09" is the frame and rated current (9 A in AC-3), "10" is the built-in auxiliary contact (one normally open), "A" means an AC coil and "230" is the coil voltage. The coil voltage must match the control circuit exactly, so it is the most common detail to check when replacing one. For motors, a soft starter limits the inrush current at start and stop, while a variable speed drive controls the speed continuously and saves energy on pumps and fans that do not need full flow all the time.
Where Lovato products are used
In Oman and the GCC, Lovato components are built into motor control centres, pump and HVAC panels, capacitor banks for power factor correction, generator and ATS panels, and machine control panels for industry, water and buildings.
Ordering Lovato products: what we need
Send the full Lovato order code. For contactors and starters, confirm the coil or control voltage. For drives and soft starters, send the motor power, current and supply voltage. For power factor controllers, send the number of steps and the CT ratio.
Facts checked against Lovato Electric company profile brochures, October 2026.
Browse Lovato Electric products by category: Motor Soft Starters, Automation Accessories, Controllers & Data Acquisition, PLC & I/O Cards, Circuit Breakers, Diesel Generator Spare Parts.
Related products
Frequently Asked Questions
4-6.5 A.
10A.
Yes, phase failure detection is listed in the datasheet.
Manual or automatic.
1 NO and 1 NC.

Reviews
There are no reviews yet.