The CES-AP-CL2-AH-SB-111747 (order number 111747) is a EUCHNER CES-AP safety switch with RFID unicode coding. Its 0.2 m PUR connecting cable ends in an M12 plug connector, which is what makes this variant convenient for direct connection to decentralized IP67 I/O modules; EUCHNER names the Siemens ET 200pro and ET 200eco, Murr MVK and Beckhoff EP1957 as examples. Each actuator is highly coded, the switch only recognises taught-in actuators, and only the last taught-in actuator is detected.

Two redundant semiconductor safety outputs with internal monitoring and test pulses give the device Category 4 / PL e (EN ISO 13849-1) and SIL 3 (EN IEC 62061) suitability, with a PFH of 1.8 x 10^-9 per hour. A STATE and a DIA LED show switching state and diagnostics.

Technical specifications

Parameter Specification
Order number 111747
Technology RFID, unicode coding: only taught-in actuators are detected
Connection PUR cable 0.2 m with M12 plug connector, 5-pin (pin 5 not used)
Intended connection Decentralized IP67 peripheral (I/O) systems, for example ET 200pro, ET 200eco, MVK, EP1957
Operating voltage UB 24 V DC, -15% to +15%, regulated, low residual ripple
Current consumption Max. 30 mA without load currents
External fuse 0.25 to 8 A
Safety outputs OA / OB Two p-switching semiconductor outputs, short-circuit proof
Output voltage LOW 0 to 1 V; HIGH UB-1.5 V to UB
Switching current per output 1 to 150 mA (DC-13, 24 V, 150 mA)
Discrepancy time Max. 10 ms
Test pulse Max. 0.3 ms duration, min. 100 ms interval
Turn-on time of safety outputs Max. 300 ms; ready delay 0.5 s
Risk time (EN 60947-5-3) Max. 260 ms
Rated insulation voltage Ui / impulse Uimp 75 V / 1.5 kV
Safety class / degree of contamination III / 3
PL / category / PFH PL e / Category 4 / 1.8 x 10^-9 per hour; mission time 20 years
Maximum SIL SIL 3 (EN IEC 62061)
Switch-on distance with CES-A-BDN-06-104730 19 mm; secured switch-off 40 mm (x/z), 60 mm (y); secured switching distance min. 14 mm
Switch-on distance with CES-A-BLN actuators 15 mm; secured switch-off 40 mm (x/z), 60 mm (y); secured switching distance min. 10 mm
Switching hysteresis / repeat accuracy 1 to 2 mm / 10 %
Switching frequency Max. 1 Hz
Mounting Surface mounting on metal; min. 400 mm between switches; tightening torque max. 1 Nm
Degree of protection IP67
Housing Plastic, PBT
Storage temperature -25 to 70 C
Cable ambient temperature Static -25 to 65 C; dynamic -5 to 65 C
Cable bending radius Static 5 x diameter; dynamic 10 x diameter
UL note Operate with UL Class 2 power supply or equivalent measures

Actuators, distances and mounting

The actuator is not included. EUCHNER lists CES-A-BDN-06-104730 and the CES-A-BLN-R2-100776, -U2-103450, -L2-104510 and -U2-112710 actuators for this switch. EUCHNER’s typical-operating-distance diagram refers to a CES-A-BLN actuator with the switch mounted on plastic; the actuating range changes with actuator, substrate material and installation, so verify it against the operating instructions. For a side approach the minimum distance is 6 mm so the side lobes are not entered, and adjacent switches need at least 400 mm between them.

For hinged doors the page quotes a left-hand door hinge variant. If you need a plain M12 variant for cabinet use or a coded set with an actuator included, compare with the EUCHNER CES-I-BR-C07 non-contact set already listed on our site.

Related EUCHNER products: EUCHNER CES-IA-BR-U-C07-SA Non-Contact Safety Switch Set, EUCHNER TZ1RE024SR11 Guard Locking Safety Switch, 24 V, EUCHNER CTP-I-AP-U-HA-ZZ-SA Safety Switch without Guard Locking, EUCHNER CTP-L1-BP-U-HA-AZ-SA Guard Locking Safety Switch, EUCHNER CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety Switch and EUCHNER CTA-L1-BP-U-HA-AP-SA Guard Locking Safety Switch.

Documents and quotation

The EUCHNER operating instructions for the non-contact safety switch CES-AP-C2 (document 2105360, English) are attached. Confirm the cable length, plug, actuator and coding before ordering. Seven Star LLC is an independent supplier in Muscat and quotes the exact order code you send.

More products in this range: Safety Switches & Guard Locking.

Datasheets & Documents
  • PDF Operating instructions EUCHNER CES-AP-C2 safety switch operating instructions (EN, doc. 2105360) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.

Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.

EUCHNER company profile

Origins 1940, engineering office of Emil Euchner near Stuttgart, Germany
Company founded 1953, as EUCHNER + Co.
Headquarters Leinfelden-Echterdingen, Baden-Württemberg, Germany
Ownership Family-owned
Product families Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems

Milestones

  • 1940: Emil Euchner sets up an engineering office.
  • 1952: He develops the first multiple limit switch.
  • 1953: EUCHNER + Co. is founded.

EUCHNER product series

Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.

Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.

Where EUCHNER components are used

Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.

EUCHNER products we list

Family Examples
Safety Switches & Guard Locking CES-IA-BR-U-C07-SA Non-Contact Safety Switch, CTA-L1-BP-U-HA-AP-SA Guard Locking Safety, CTM-LBI-BP-U-AZ-SA BiState Guard Locking, CTP-I-AP-U-HA-ZZ-SA Safety Switch without, CTP-L1-BP-U-HA-AZ-SA Guard Locking Safety, CTS-C1-BP-CC-FLX-AP-USA Guard Locking Safety, ESM-BA301 Safety Relay, ESM-BT411 Safety Relay with Time-Delayed and 9 more

Ordering EUCHNER components: what we need

Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.

Facts checked against EUCHNER's published company history, October 2026.

FAQ

Questions about the EUCHNER CES-AP-CL2-AH-SB-111747 RFID Safety Switch,

Answers from our engineering team on installation, compatibility and integration.

01What is the EUCHNER CES-AP-CL2-AH-SB-111747?
It is a non-contact CES-AP safety switch with RFID unicode coding, order number 111747, with a 0.2 m PUR cable and M12 5-pin plug for decentralized peripheral systems.
02What safety rating does the switch reach?
The data sheet states suitability for Category 4 / PL e per EN ISO 13849-1 and SIL 3 per EN IEC 62061, with two redundant semiconductor safety outputs and a PFH of 1.8 x 10^-9 per hour.
03Which actuator works with this switch?
EUCHNER lists CES-A-BDN-06-104730 and the CES-A-BLN-R2/U2/L2 actuators. The actuator is not included and must be ordered separately.
04What supply and degree of protection does it have?
The supply is 24 V DC with -15% to +15% tolerance, regulated, and the degree of protection is IP67. Current consumption is max. 30 mA without load currents.
05Where can I get the manual and a quotation?