Brand: Beamex
Beamex PGC Pressure and Vacuum Calibration Hand Pump
Description
One field pump for both gauge pressure and vacuum
The Beamex PGC is a hand-operated calibration pump that generates either pressure or vacuum with air as the medium, covering -0.95 to 35 bar (-13.7 to 510 psi). A selector on the pump head switches between pressure and vacuum, so a technician can check a transmitter, gauge or switch on both sides of atmospheric with one tool. A fine adjustment valve trims the generated pressure to the exact test point, and a release valve vents the system when the test is done.
The PGC is used together with a pressure calibrator or reference gauge, such as the Beamex MC6 or MC2 with an internal or external pressure module; the pump creates the pressure and the calibrator measures it.
Technical specifications
Values from the Beamex PG calibration pumps brochure (2025).
| Parameter | Specification |
|---|---|
| Model | Beamex PGC |
| Output pressure | -0.95 to 35 bar / -13.7 to 510 psi |
| Pressure medium | Air |
| Output connector | G1/8 in. female; pre-installed Bx G1/8 in. male fitting for Beamex 40 bar (600 psi) hoses |
| Controls | Pressure/vacuum selector, fine adjustment valve, release valve, stroke length setting |
| Dimensions | 220 x 120 x 65 mm (8.7 x 4.7 x 2.6 in.) |
| Weight | 820 g (1.81 lb) |
| Standard delivery | 40 bar T-hose set, pressure fitting set for 40 bar hoses, hard carrying case |
Using the stroke length setting
The PGC has an adjustable stroke length. A long stroke moves more air per squeeze and reaches the target quickly in larger test volumes; a short stroke makes it easier to reach the upper end of the range by hand. In practice, keep the test volume small with short hoses, check fittings for leaks before recording readings, and allow a short settling time after pumping, since air heats when compressed and the pressure drifts slightly as it cools.
Where it sits in the Beamex PG pump range
Beamex lists five PG calibration pumps in the current brochure, so the right one follows from the range and medium needed:
| Model | Type | Pressure range |
|---|---|---|
| PGM | Hand pump, air | 0 to 20 bar / 0 to 300 psi |
| PGC | Hand pump, air, pressure and vacuum | -0.95 to 35 bar / -13.7 to 510 psi |
| PGHH | Hydraulic hand pump | 0 to 700 bar / 0 to 10,000 psi |
| PGPH | Pneumatic table pump | -0.95 to 140 bar / -13.7 to 2000 psi |
| PGL | Low-pressure screw pump, air | -400 to +400 mbar / -160 to 160 iwc |
Documents and quotation
The official Beamex PG pump brochure (April 2025) gives the specifications of all five models. When requesting a quotation, state the pump model, the pressure fittings or hoses needed for your instruments and whether a hard carrying case is required. Other field calibration equipment is listed under Portable Test and Measurement.
How the Beamex PGC calibration pump works
The PGC is a hand-operated pneumatic calibration pump that uses ambient air as the pressure medium. According to the Beamex PG pumps brochure, its output range is −0.95 to 35 bar (−13.7 to 510 psi), so a single pump covers both vacuum and moderate positive pressure. A selector sets pressure or vacuum, the pump strokes build the pressure, a release valve lowers it, and a fine volume adjuster sets the final value precisely. The pump comes with a preinstalled Beamex G1/8 in. male fitting for Beamex 40 bar hoses, and the standard delivery includes a 40 bar T-hose set, a pressure fitting set for 40 bar hoses and a hard carrying case.
Using the Beamex PGC in the field
- Connect the reference pressure module or calibrator and the device under test to the T-hose set.
- Select pressure or vacuum and pump close to the first test point.
- Fine-tune the pressure with the volume adjuster and allow it to stabilise.
- Record reference and device readings, then step through the remaining test points and back down.
- Release pressure fully before disconnecting.
Selection guide within the PG range
- PGL for low pressures up to ±400 mbar, such as draft and differential pressure transmitters.
- PGC for vacuum up to 35 bar.
- PGPH for pneumatic vacuum and pressure from -0.95 to 140 bar.
- PGHH for hydraulic pressure up to 700 bar.
Care and maintenance
- Avoid drawing liquids or dirt into the pump; use a trap when calibrating instruments with wet process connections.
- Check seals and hoses regularly and keep fittings clean.
- Store the pump in its case when not in use.
Typical applications in Oman and the GCC
A vacuum-to-35 bar hand pump suits field calibration of pressure transmitters, gauges and switches in oil and gas, power, water and desalination plants, where instrument technicians need a portable pressure source without cylinders.
Why source from Seven Star LLC
Seven Star LLC supplies Beamex calibration equipment across Oman and the GCC. Request a quote with the pump model, hoses and adapters you need, and our team can help confirm the correct ordering code.
Building a complete calibration kit
A calibration pump only generates pressure; the accuracy of the calibration comes from the reference instrument. In a typical field kit, the pump is combined with a documenting calibrator or a reference pressure module whose range matches the instruments being tested. The reference should be several times more accurate than the device under test, and its calibration certificate should be valid. Hoses and adapters must suit both the pressure rating and the process connections found on site, such as NPT, BSP or metric threads. Keeping a written procedure for each instrument type helps technicians repeat calibrations consistently, record as-found and as-left results, and decide whether an instrument needs adjustment or replacement.
Calibration records and audits
Pressure instrument calibration results are often reviewed during quality, safety and environmental audits. Recording the reference used, the test points, ambient conditions and the technician name supports traceability. Electronic calibration management software can schedule recalibration intervals and store certificates, reducing paperwork for maintenance teams.
See also: Beamex MC2 Hand-Held Process Calibrator; Beamex EXT External Pressure Modules, 70 kPa to 100 MPa; Beamex 9010900 DMT40 Dirt and Moisture Trap 40 bar; Beamex 8003370 630 bar Pressure T-Hose Set (2 m) for EXT; Beamex 8003340 Hard Case for PGM and PGV Pumps.
Datasheets & Documents
- Brochure Beamex PG calibration pumps brochure: PGM, PGC, PGHH, PGPH, PGL (EN, 2025) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex PGC Pressure and Vacuum Calibration Hand Pump
Answers from our engineering team on installation, compatibility and integration.
01What pressure range does the Beamex PGC cover?
From -0.95 bar vacuum up to 35 bar (-13.7 to 510 psi), using air as the pressure medium.
02How do I switch between pressure and vacuum on the PGC?
A pressure/vacuum selector on the pump body sets which one the strokes generate.
03What connection does the PGC have?
A G1/8 in. female output, with a pre-installed Beamex Bx G1/8 in. male fitting for Beamex 40 bar (600 psi) hoses.
04What comes with the PGC?
Beamex lists a 40 bar T-hose set, a pressure fitting set for 40 bar hoses and a hard carrying case.
05Can the PGC calibrate a 100 bar transmitter?
No. Its maximum is 35 bar. For pneumatic ranges up to 140 bar Beamex offers the PGPH table pump, and the PGHH for hydraulic work.