Brand: EUCHNER
EUCHNER CTP-L1-BP-U-HA-AZ-SA Guard Locking Safety Switch
Description
Transponder-coded guard locking for hazardous run-down
The EUCHNER CTP-L1-BP-U-HA-AZ-SA (order no. 166752) is a transponder-coded safety switch with guard locking from the CTP family. It holds a safety door closed until the machine has reached a safe state, for example until a spindle, rotor or press has stopped. The evaluation electronics are integrated, so the switch delivers two monitored semiconductor safety outputs directly to a safety controller or safety relay.
The code letters describe the version: L1 means guard locking by spring force with release by applying power (closed-circuit current principle), and U stands for unicode evaluation, where the switch only accepts the last actuator that was taught in. The actuating head is approached horizontally; in the delivery state, approach directions A, B and C are possible, and the head can be turned in 90° steps.
Technical specifications
| Parameter | Specification |
|---|---|
| Order number | 166752 |
| Guard locking principle | Closed-circuit current (spring-locked, power-ON released) |
| Locking force | Fmax 3900 N; FZh 3000 N |
| Coding | Unicode (RFID transponder) |
| Electronics operating voltage | 24 V DC, -15% to +20%, regulated |
| Solenoid operating voltage | 24 V DC, -15% to +20%; 100% duty cycle |
| Current consumption | Solenoid 400 mA; electronics 40 mA |
| Safety outputs | FO1A/FO1B, 2 p-switching semiconductor outputs, 1 to 150 mA; DC-13 24 V 150 mA |
| Monitoring outputs | OD (door position), OI/C (diagnosis/communication), 1 to 50 mA |
| Risk time | max. 270 ms; +5 ms per additional device |
| Connection | 1 x M12 plug connector, 8-pin |
| Actuating / extraction / retention force | 10 N / 20 N / 20 N |
| Approach speed / overtravel | max. 20 m/min / 5 mm |
| Mechanical life | 1 x 10⁶ operations |
| Degree of protection | IP65 / IP67 / IP69 / IP69K (connector screwed tight) |
| Ambient temperature | -20 to +55 °C |
| Housing / head | Reinforced thermoplastic / die-cast zinc |
| Guard lock monitoring | PL e, category 4, PFHD 5.38 x 10⁻⁹, 20 years |
Connection, diagnostics and series wiring
All signals run through one 8-pin M12 connector: separate 24 V supplies for the electronics and the locking solenoid, the two safety outputs, the door position output and a diagnostic output that can also communicate. In combination with an EUCHNER IO-Link gateway GWY-CB or ESM-CB, the switch can pass status and diagnostic data to the controller. The device has an auxiliary release on the front for opening the door during commissioning or a power failure, secured with a locking screw.
Because the switch uses the closed-circuit current principle, the door stays locked when power is lost. This is the usual choice when an open door during run-down would put a person at risk; check whether an escape release or rescue procedure is needed for walk-in guards.
Selecting actuators and accessories
The actuator is ordered separately. EUCHNER lists straight, bent and hinged CTP/CTA actuators, for example A-C-H-G-SST-126015 (straight) and A-C-H-W-SST-122667 (bent at top). Hinged actuators are offered for left, right, top and bottom hinged doors. Connecting cables with straight or angled M12 8-pin sockets in PUR or PVC are available in lengths of 10, 20 and 30 m. The safety outputs need a free-wheeling diode when switching inductive loads.
Documents and quotation
The attached EUCHNER operating instructions cover CTP-L1/2-BP devices, including wiring, teach-in and the auxiliary release. For a quotation, send the order number 166752, the actuator type, the cable type and length, and the quantity. See Safety Switches & Guard Locking for related EUCHNER devices.
How the CTP-L1-BP-U-HA-AZ-SA Guard Locking Works
The switch combines two functions in one housing. The first is guard position monitoring: an RFID transponder in the actuator is read by the switch head when the door is closed, and the switch checks the code against the taught-in actuator. The second is guard locking: a bolt in the switch holds the actuator, so the door cannot be opened while the bolt is engaged. The safety outputs are only switched on when the door is closed, the correct actuator is detected and the guard locking is engaged and monitored.
With the L1 version, the bolt is held in the locked position by a spring. To unlock, the safety controller applies 24 V to the solenoid, normally only after a standstill monitor or time delay confirms that hazardous motion has stopped. If power fails, the spring keeps the door locked. This closed-circuit current principle is the version normally used for personnel protection where a run-down hazard exists, as described in ISO 14119.
Installation & Commissioning
- Mount the switch and actuator so the actuator enters the head without side load, and fit a separate mechanical end stop for the door; the switch must not be used as a door stop.
- Use tamper-resistant fixing as required by ISO 14119, for example one-way screws or covered fixing holes.
- Teach in the actuator during commissioning; with unicode evaluation, only the last taught actuator will be accepted.
- Wire the safety outputs to a safety controller or safety relay with suitable cross-fault detection, and check the full safety function before handing over the machine.
- Instruct operators and maintenance staff on the auxiliary release and keep its locking screw sealed during normal operation.
Typical Applications in Oman & the GCC
Guard locking switches of this type are used on machine tools, centrifuges, presses, robot cells, packaging machines and test benches, wherever a person could reach a hazard before it has stopped. The high degree of protection suits wash-down and outdoor-adjacent installations. Seven Star LLC supplies EUCHNER safety switches across Oman and the GCC; send the order number and the actuator and cable required, and our team can help confirm the correct combination.
Planning the unlocking sequence
Guard locking only adds safety if the unlock signal is generated correctly. Typical sequences use a standstill monitor on the motor, a safe speed function in the drive or a fixed time delay longer than the worst-case run-down time. The operator presses a request button, the controller waits for the safe state and only then energises the solenoid. Define this logic in the risk assessment and validate it during commissioning, together with the response of the system when power is lost and restored.
See also: EUCHNER MSC-CB-AC-FI8FO2 Modular Safety Controller Base Unit; EUCHNER ESM-BT411 Safety Relay with Time-Delayed Contacts.
Datasheets & Documents
- Operating instructions EUCHNER CTP-L1/2-BP operating instructions (EN, 01/2024) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
EUCHNER is the German maker of safety switches, guard locking devices, enabling switches, safety controllers and multiple limit switches for machine safety and motion control. Its history began in 1940, when Emil Euchner set up an engineering office near Stuttgart; he developed the first multiple limit switch in 1952 and founded EUCHNER + Co. in 1953. The family-owned company is headquartered in Leinfelden-Echterdingen near Stuttgart.
Seven Star LLC is an independent supplier in Muscat. We list EUCHNER safety components for machine builders and maintenance teams in Oman and the GCC.
EUCHNER company profile
| Origins | 1940, engineering office of Emil Euchner near Stuttgart, Germany |
|---|---|
| Company founded | 1953, as EUCHNER + Co. |
| Headquarters | Leinfelden-Echterdingen, Baden-Württemberg, Germany |
| Ownership | Family-owned |
| Product families | Transponder-coded safety switches with guard locking (CTM, CTP, MGB), TZ and TX guard locking switches, ZSB enabling switches, MSC modular safety controllers, multiple limit switches, electronic hand wheels and access systems |
Milestones
- 1940: Emil Euchner sets up an engineering office.
- 1952: He develops the first multiple limit switch.
- 1953: EUCHNER + Co. is founded.
EUCHNER product series
Guard locking switches include the transponder-coded CTP, CTA and CTS series, the CTM with BiState guard locking, the STP twin switch and the electromechanical TX1B and TZ series. The MGB2 Multifunctional Gate Box combines guard locking, handle and control elements on one door. Non-contact switches include the CES-IA set and the CES-AP RFID safety switch, and the CTP-I version provides monitoring without guard locking.
Control devices include the ZSM and ZSB three-position enabling switches, the RPS emergency stop rope pull switch, the ESM safety relays (including versions with time-delayed contacts and the ESM-TE301 expansion) and the MSC modular safety controller.
Where EUCHNER components are used
Safety guards and doors on machine tools, robot cells, presses, packaging machines and conveyor systems, emergency stop along conveyors and enabling during setup and teaching. A switch or actuator is one part of a safety function; the complete system must be designed and validated for its application.
EUCHNER products we list
Ordering EUCHNER components: what we need
Send the full order number or item number from the label, the coding level and actuator required, the supply voltage and the connection type. For replacements, also give the installed device details and the mating components such as actuators and handle modules.
Facts checked against EUCHNER's published company history, October 2026.
Browse EUCHNER products by category: Safety Switches & Guard Locking.
FAQ
Questions about the EUCHNER CTP-L1-BP-U-HA-AZ-SA Guard Locking Safety
Answers from our engineering team on installation, compatibility and integration.
01Is the CTP-L1-BP-U-HA-AZ-SA spring-locked or magnet-locked?
It is spring-locked. Guard locking is applied by spring force and released by applying power to the solenoid (closed-circuit current principle).
02What is the locking force?
EUCHNER specifies a maximum locking force of 3900 N and FZh of 3000 N, depending on the actuator used.
03Is the actuator included?
No actuator is listed in the scope. Choose a straight, bent or hinged CTP/CTA actuator from the EUCHNER accessory list.
04What does unicode mean for this switch?
Each actuator is highly coded. The switch only accepts the last actuator that was taught in, which makes defeating the guard more difficult.
05Which connector does it use?
A single 8-pin M12 plug connector carries the supplies, safety outputs and monitoring outputs.


















Reviews