Brand:

Viking Pump AK4195 Motor Speed Gear Pump 85 GPM Cast Iron

Description

Overview

Viking Pump AK4195 is a mid-size motor speed gear pump with 2-1/2 inch NPT ports, rated 85 GPM (19 m3/h) at 1750 rpm on 60 Hz power or 70 GPM (16 m3/h) at 1450 rpm on 50 Hz power. It is the AK frame of the 4195 Series, a cast iron pump whose mechanical seal sits behind the rotor so that the shaft and bearings never touch the pumped liquid. The result is a robust, easy-to-service pump for oils, fuels and other non-corrosive liquids from thin to moderately viscous. Seven Star LLC is an independent supplier serving Oman and the GCC.

Many buyers meet this code on an existing nameplate and need a like-for-like replacement, so this page lists the numbers that matter when matching an AK4195 to an installed system: port size, speeds, pressure limits, materials and weight.

Design features of the Viking Pump AK4195

Viking Pump describes the 495 and 4195 designs as having achieved something once thought impossible: high flow at motor speeds from a gear pump. The largest sizes of the series reach 580 GPM, and the AK frame sits in the middle of the range. Sealed-for-life anti-friction bearings remove the need for lubrication. A threaded one-piece bearing housing allows end clearance to be set accurately and reduces wear caused by misalignment. Standard gauge ports allow pressure to be read at the pump, and static O-ring seals help keep thin liquids inside.

The AK frame uses a ductile iron rotor and ductile iron idler (ASTM A536 Grade 60-40-18), a hardened steel idler pin and carbon graphite idler bushing, with a cast iron relief valve integral with the casing.

Specifications

Parameter Value
Model AK4195, 4195 Series, cast iron, behind-the-rotor mechanical seal
Port size 2-1/2 inch NPT
Capacity at 60 Hz 85 GPM (19 m3/h) at 1750 rpm
Capacity at 50 Hz 70 GPM (16 m3/h) at 1450 rpm
Maximum differential pressure 250 PSIG (17 bar)
Maximum hydrostatic pressure 400 PSIG (27 bar)
Maximum viscosity 15,000 SSU (3,300 cSt)
Maximum temperature 300 F (150 C)
Series temperature range -40 to +300 F (-40 to +150 C)
Approximate shipping weight 85 lb (39 kg)
Rotor and idler Ductile iron, ASTM A536 Grade 60-40-18
Shaft Steel, ASTM A108 Grade 1045
Seal faces Carbon versus silicon carbide, FKM elastomers
Bearings Steel with Buna seals, sealed for life

AK4195 compared with similar models

Next to it in the A-frame are AS4195 (55 GPM at 1750 rpm) and AL4195 (115 GPM at 1750 rpm), both with 2-1/2 and 3 inch NPT ports respectively. The AK495 has the same hydraulic size as AK4195, so a replacement requires attention to the suffix: the catalog lists dimension pages and drive layouts separately for the 495 and 4195 builds. Above this size the KE, KKE, LQE and LSE frames move from 150 up to 235 GPM through 4 inch flanged ports with a lower 150 PSIG differential pressure.

Applications for AK4195

Because the seal is behind the rotor, solids that settle in a stuffing box cannot lock the shaft, a point appreciated in fuel service where scale or rust may circulate. Fuel transfer at depots and power stations, lube oil circulation on large rotating equipment, hydraulic fluid and cooling oil circuits, tanker unloading of light oils, and process oil transfer in industrial plants are typical. The pump also appears on skid-mounted packages for burner fuel supply, because direct drive from a standard motor avoids a speed reducer. In the Gulf, high ambient temperatures make the 300 F rating comfortable for outdoor fuel service.

Selection and mounting for Viking Pump AK4195

Selection starts with frequency because motor-speed pumps deliver the catalog flow only at the stated rpm. At 50 Hz the AK4195 delivers 70 GPM, about 18 percent less than at 60 Hz, so a Gulf project with 50 Hz supply should size from the 50 Hz figure. Next check that the temperature and viscosity of the liquid fall inside the stated limits, and finally verify that FKM suits the liquid. For aggressive chemicals a stainless series is the better choice.

  • Match power frequency: 85 GPM at 60 Hz, 70 GPM at 50 Hz.
  • Check pump viscosity limit of 15,000 SSU against your product at the lowest temperature.
  • Choose NEMA or IEC mounting to suit the motor.
  • Check that FKM elastomers suit the liquid.
  • Provide a return line for the relief valve.

Installing and starting the pump

The pump can be bolted to a mounting bracket with a motor flange, or supplied on a baseplate with a coupling. Whatever the arrangement, keep the suction line short and at least as large as the 2-1/2 inch port, vent the casing before starting, and check rotation. Fit a strainer and a vacuum gauge on the suction side and a pressure gauge on the discharge, using the standard gauge ports where possible.

Maintenance and spares

With sealed bearings the main wear items are the mechanical seal, idler bushing and idler pin. Check for seal weep during rounds, and replace the seal at first signs of leakage. Adjust end clearance using the threaded housing if capacity falls. Stock a seal kit, an idler assembly and a bushing set. Because motor-speed pumps run at high rpm, monitor vibration and temperature on the first start and record the baseline, which will make later bearing problems easy to detect.

Related items you may also need: Allweiler OptiFix Progressing Cavity Pump AEB 2E-MF and 1F-MF | KRACHT KF T15/T25 Gear Pump with T-Valve and Tank Port | KRACHT Pump Technology Series | All Viking Pump products.

If the Viking Pump AK4195 is replacing an installed unit, record the existing tag number, the process service and the supply conditions before requesting a quotation. These details make it easier to cross-check the configuration against the official documentation and to flag anything that should be verified with the manufacturer before the part is installed.

Documents and quotation

The attached catalog section is the shared document for the 495 and 4195 series. To request a quotation for Viking Pump AK4195, send the code AK4195 and quantity through the RFQ form, and state the line frequency and motor frame so that the correct mounting can be confirmed.

Datasheets & Documents
  • PDF Datasheet Viking Pump AK4195 Motor Speed Gear Pump 85 GPM Cast Iron Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Viking Pump is a global leader in positive displacement pumping solutions, building internal and external gear pumps at its base in Cedar Falls, Iowa, as an IDEX company. Its range includes the 1124C Series internal gear pumps with U-Plus bracket design and O-Pro seal technology, GB-425 Series external gear pumps for pipeline injection, RTPg tanker pumps, and hygienic rotary lobe and circumferential piston pumps. These pumps move viscous and problematic liquids across industrial, energy, hygienic and transport applications, from lubrication, fuel transfer and chemical processing to asphalt and food-grade duty. Seven Star LLC is an independent supplier serving Oman and the GCC, helping buyers specify Viking Pump models matched to their liquid, flow rate and sealing needs for dependable uptime.

FAQ

Questions about the Viking Pump AK4195 Motor Speed Gear Pump 85 GPM

Answers from our engineering team on installation, compatibility and integration.

01What is the AK4195 flow rating?
AK4195 delivers 85 GPM (19 m3/h) at 1750 rpm on 60 Hz, or 70 GPM (16 m3/h) at 1450 rpm on 50 Hz, through 2-1/2 inch NPT ports.
02Where is the seal on the AK4195?
The mechanical seal is behind the rotor, so the shaft and bearings are not exposed to the pumped liquid; seal faces are carbon versus silicon carbide with FKM.
03What pressure can the AK4195 reach?
Maximum differential pressure is 250 PSIG (17 bar) and maximum hydrostatic pressure is 400 PSIG (27 bar).
04What viscosity can the AK4195 handle?
The catalog lists a maximum viscosity of 15,000 SSU (3,300 cSt) for this frame, with temperatures up to 300 F (150 C).
05What is the weight of the AK4195?
The approximate shipping weight with relief valve is 85 lb (39 kg).