Viking Pump KK224C Jacketed Gear Pump 100 GPM 2 in
Description
Overview
Viking Pump KK224C is the jacketed twin of the KK124C: a 2 inch cast iron internal gear pump, 100 GPM (23 m3/h) at 780 rpm, with heating passages cast into both the head and the bracket. It belongs to the 224C Series, where every pump comes standard with a jacketed head and bracket, so steam, hot oil or warm water can keep a product fluid from the suction port to the shaft seal. Seven Star LLC is an independent supplier serving Oman and the GCC.
Typical liquids are the ones that thicken or solidify at room temperature: bitumen blends, waxes, fats, heavy fuel oil, molasses-type syrups, polymers, resins and some adhesives. If the liquid flows freely at ambient temperature, a non-jacketed model usually costs less and is simpler to pipe.
How the jacket works on Viking Pump KK224C
A jacket is simply a cavity on the outside of the pump through which a heating or cooling medium flows. On the 224C series the jacket covers the head and the bracket, which are the areas around the seal and the rotor end where liquid stagnates and chills first. Because the heat reaches the seal chamber, packing or seal faces stay supple and the pump can restart after a shutdown without the rotor locking in solid product.
Jacket connections are tapped for pipe fittings, and the catalog lists a series of relief valve configurations, including jacketed and non-jacketed relief valves, so the return line does not freeze. The pump can also be used in reverse service to cool a hot liquid with a cooling medium in the jacket.
Technical data
| Parameter | Value |
|---|---|
| Model | Viking Pump KK224C, 224C Series, cast iron, jacketed head and bracket |
| Port size | 2 inch NPT |
| Nominal capacity | 100 GPM (23 m3/h) |
| Rated speed | 780 rpm |
| Maximum hydrostatic pressure | 400 PSIG (28 bar) |
| Maximum discharge pressure | 200 PSI (14 bar) |
| Maximum temperature, standard pump | 450 F (230 C) |
| Series viscosity range | 28 to 2,000,000 SSU (0.1 to 440,000 cSt) |
| Shipping weight with valve | 114 lb (52 kg) |
| Casing, head, head plate, bracket | Cast iron, ASTM A48 Class 35B |
| Rotor | Ductile iron, ASTM A536 Grade 60-40-18 |
| Idler bushing and bracket bushing | Bronze, ASTM B584 alloy C93700 |
| Shaft sealing | Braided PTFE packing |
KK224C versus related codes
Comparing with KK124C is natural. Both share the 2 inch NPT port, 100 GPM rating and 780 rpm speed, but the jacketed Viking Pump KK224C weighs 114 lb (52 kg) against 108.29 lb (49.2 kg) for the non-jacketed pump. Other variants in the same section include KK1224C, which has the O-Pro barrier seal and is limited to 350 F (175 C), and KK4224C, which uses a mechanical seal at the same 350 F limit. Neighbouring sizes include K224C and L224C.
Where the KK224C is used
Hot climates may seem to reduce the need for jackets, yet many liquids still thicken in storage tanks, insulated lines or air-conditioned plant rooms, and some, like bitumen or wax, are solid at ambient. Jacketed pumps remove the need for long heat-traced lines. In Oman and the GCC, jacketed gear pumps appear in bitumen and asphalt emulsion plants, in refinery slop oil and fuel oil forwarding, in food-grade fat and chocolate lines using non-sanitary industrial duty, and in resin plants where polyol must be pumped warm. Where road works need a hot-oil jacketed pump for binder transfer, this size is a common midrange choice.
Choosing jacket media and seals for Viking Pump KK224C
The jacket medium is chosen from what the plant already has. Low pressure steam is the most common and gives a stable temperature. Hot oil allows temperatures above the steam range but needs a separate circulating loop. Warm water suits liquids that only need mild heating, such as some fats and adhesives. Whatever the medium, the jacket pressure rating should be confirmed with the catalog dimension pages before piping.
- Steam jackets need condensate drains at the lowest point.
- Hot oil jackets need a circulation pump with enough pressure to overcome jacket losses.
- For zero-leak sealing choose the KK4224C mechanical seal or the KK1224C O-Pro seal.
- Packing, as on Viking Pump KK224C, is best when the liquid is abrasive.
- Match jacket medium temperature to the 450 F (230 C) pump rating.
Installation and start-up
Prepare a baseplate with space for jacket piping, valves and a steam trap or hot oil return, and keep the coupling guard accessible. Install the pump with the jacket ports accessible and add isolation valves so the pump can be removed without draining the heating system. Start the jacket flow first and wait until the liquid is thin enough to move, then prime and start the pump. Never start on frozen product, because the rotor can seize and shear the shaft. Adjust packing slowly after the pump reaches temperature, since heat expands the rings.
Maintenance
A jacketed pump has two circuits to look after: the process side and the heating side. On the process side follow the normal gear pump routine of packing adjustment, bushing checks and end clearance reset through the rotatable bearing housing. On the heating side watch for leaks at jacket joints and for scale or sludge that reduces heat transfer. Flush the jacket in cold weather, check for scale in steam passages and inspect hoses regularly. Replace the packing when it no longer seals after tightening, and renew bronze bushings when you detect shaft play. Maintain a log of jacket temperature and discharge pressure to detect fouling early.
Related items you may also need: KRACHT RA 28-Z35/24-Z35/38 Coupling for KF Gear Pump | KRACHT KP 1/4 G10A K0A 4NL1 High-Pressure Gear Pump | Tapflo T200 PE and PTFE Air-Operated Diaphragm Pump | All Viking Pump products.
Before you order the Viking Pump KK224C
- To avoid a wrong delivery, compare the code on the nameplate of the installed unit with the Viking Pump KK224C code on this page.
- The quotation for the Viking Pump KK224C states the confirmed code and the lead time to site.
- The attached manufacturer datasheet covers the Viking Pump KK224C ratings, dimensions and installation details.
Documents and quotation
The attached catalog section covers the full jacketed cast iron range, including the 224C, 1224C and 4224C series with dimensions and options. To request a quotation for Viking Pump KK224C, send the code Viking Pump KK224C with the quantity through the RFQ form and state the jacket medium and temperature.
Datasheets & Documents
- Datasheet Viking Pump KK224C Jacketed Gear Pump 100 GPM 2 in Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Viking Pump is a global leader in positive displacement pumping solutions, building internal and external gear pumps at its base in Cedar Falls, Iowa, as an IDEX company. Its range includes the 1124C Series internal gear pumps with U-Plus bracket design and O-Pro seal technology, GB-425 Series external gear pumps for pipeline injection, RTPg tanker pumps, and hygienic rotary lobe and circumferential piston pumps. These pumps move viscous and problematic liquids across industrial, energy, hygienic and transport applications, from lubrication, fuel transfer and chemical processing to asphalt and food-grade duty. Seven Star LLC is an independent supplier serving Oman and the GCC, helping buyers specify Viking Pump models matched to their liquid, flow rate and sealing needs for dependable uptime.
FAQ
Questions about the Viking Pump KK224C Jacketed Gear Pump 100 GPM 2 in
Answers from our engineering team on installation, compatibility and integration.
01What makes the KK224C different from the KK124C?
KK224C has jacketed head and bracket for steam, hot oil or warm water, while KK124C is non-jacketed. Capacity, speed and ports are the same.
02What is the KK224C capacity?
It is rated 100 GPM (23 m3/h) at 780 rpm with 2 inch NPT ports for liquids of 100 SSU and below.
03What temperature can the KK224C handle?
The standard packed pump is listed to 450 F (230 C). Mechanical seal and O-Pro versions of the series are limited to 350 F (175 C).
04How heavy is the KK224C?
The catalog lists a shipping weight with relief valve of 114 lb (52 kg).
05What seal is fitted to the KK224C?
Braided PTFE packing is standard. KK4224C uses a mechanical seal and KK1224C uses the O-Pro barrier seal.