Brand:

Verder VA08 Non-metallic Air-Operated Double Diaphragm Pump 1/4 in.

Description

Overview

Most air diaphragm pumps need to stand upright so that their check balls can fall back onto the seats. The Verder VA08 Non-metallic breaks that rule. Verder fits it with spring-operated check valves made from Hastelloy, so the pump can be installed in any position, including upside down. It is the smallest pump in the Verderair VA range, with quarter inch ports, a flow of up to 5 US gpm and a body of acetal, polypropylene or Kynar (PVDF). Seven Star LLC is an independent supplier serving Oman and the GCC.

What is special about the Verder VA08

The spring-loaded valves are the key feature. Instead of loose balls, each valve has a spring that holds the closure on its seat, so gravity plays no part. That allows a designer to tuck the pump into a machine frame, mount it on a vertical panel or hang it from a bracket. Verder also lists the usual Verderair advantages: self-priming, run-dry capability, a non-stalling air valve and no need for air lubrication. The check valve seats are not removable, which is noted in the code table by a double dash in field three.

Technical data for Verder VA08

Property Datasheet value
Liquid connection 1/4 in. BSP or NPT (code TX)
Air connection 1/4 in. NPT
Maximum flow 5.02 US gpm
Maximum discharge pressure 7 bar (101.5 psi)
Dry suction lift 2.5 m water column
Wet suction lift 4.4 m water column
Maximum particle size 1.5 mm
Maximum viscosity 500 mPas
Temperature, all internals 0 to 82 degrees C
Weight, acetal 1.1 kg
Weight, polypropylene 0.9 kg
Weight, Kynar 1.3 kg
Check valves Spring operated, Hastelloy springs
Diaphragms Santoprene or PTFE
ATEX marking II 2 GD c IIC T4

VA08 compared with the other small Verderair pumps

The VA10 has 3/8 inch ports, delivers 6.6 gpm, accepts 1.6 mm particles and 1000 mPas, but is limited to 65 degrees C and must stand upright because it uses balls. The Verder VA08 gives up some flow, only 5 gpm, and viscosity, 500 mPas, but gains 82 degrees C for every internal material and the freedom to be mounted in any orientation. It is about half the weight of a VA10: 0.9 to 1.3 kg against 2.2 to 2.4 kg. The VA15 offers 15 gpm. Pick the VA08 for tight spaces, light duty dosing and machine-building projects where a pump has to fit a compact machine.

Typical uses in Oman and the Gulf

A pump this small suits laboratory benches, analyzers, small treatment skids and machine builders. Typical jobs are dosing small flows of chemicals into process lines, circulating sampling fluids, feeding ink or coating to equipment, and moving cleaning liquid in washing machines. Because the pump can be fixed on a vertical wall of a panel or on a movable arm, it is helpful in compact skid packages built for desalination, oil and gas and water treatment duties in the region.

Installing the Verder VA08

Fix the pump to a stable support in whatever orientation suits the layout. Connect small-bore tubing or hose to the quarter inch ports and a regulated, filtered air line to the quarter inch air inlet. Plastic housings are insulators, so ground the system when pumping liquids that can accumulate charge and route the exhaust to a safe place. A remote air valve option is available in the code for installations where the air valve must sit away from the pump body. Keep the suction line as short as the layout allows to achieve the stated suction lift.

Pulsation, flow range and dosing practice for the Verder VA08

At its small scale the pump is often used to dose, so the flow pattern deserves attention. Each stroke pushes a fixed small volume, so the output is pulsed and depends on the air pressure, the discharge pressure and the stroke speed. For stable dosing, supply air through a precision regulator, fix the discharge pressure with a backpressure valve, and calibrate the delivered volume over a measured time. A small accumulator on the outlet will smooth the flow when the pump feeds an analyzer or an injection quill. The spring-loaded check valves respond fast and let the pump run at a high stroke rate with small volumes, yet they also demand clean liquids, since a particle bigger than the stated 1.5 mm or fibrous matter can hold a valve open. Place a fine strainer upstream of the pump when the liquid is not already filtered, and clean it on a schedule. Viscous fluids slow the springs and the filling of the chambers, so stay under the 500 mPas limit or heat the product.

Compact engineering advantages

For machine builders, a light pump with no electrics, no seals on a rotating shaft and no need for a separate valve block means fewer failure points. The same pump can supply a coating head one day and a cleaning circuit the next, and can be replaced in minutes because it connects only through two fluid hoses and one air hose.

Maintenance

Regularly check the diaphragms, and flush the pump after use to prevent crystals from forming on the springs and seats. Replace Santoprene diaphragms when stiff or cracked, and PTFE diaphragms if they show creases. Because the seats cannot be removed, replace the valve assembly as a unit when flow drops. Keep the air supply dry and clean, and store the pump drained.

Choosing the body and diaphragm

Acetal gives strength and wear resistance but should not meet acids. Polypropylene is the economical option for acids and bases, and Kynar handles solvents and stronger chemicals at the same 82 degrees C ceiling. Santoprene diaphragms are flexible and economical, while PTFE diaphragms resist almost any chemical but give a smaller suction lift. Provide the fluid name, concentration and temperature with your enquiry.

Ordering notes for Verder VA08

The VA08 uses a seven-field code, and not every combination exists. Tell us the body material, diaphragm, thread type and whether you need a remote air valve, and we will confirm the correct code before quoting.

Related items you may also need: VERDERAIR VA50 Metallic Air-Operated Double Diaphragm Pump | Verderflex Rapide Peristaltic Tube Pump | Verder VA25 Air-Operated Double Diaphragm Pump | All Verder products.

Documents and quotation

The Verder VA08 non-metallic technosheet is attached to this page, with data, code key and performance chart. Send your RFQ with Verder VA08, the full code if known, the quantity and your delivery location in Oman or the GCC.

Other Models in the Verderair Va Range

Seven Star LLC supplies models from the Verderair Va range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Verder VA20 Metallic Air-Operated Double Diaphragm Pump 3/4 in.Positive Displacement PumpsView details
Verder VA40 Metallic Air-Operated Double Diaphragm Pump 1.5 in.Positive Displacement PumpsView details
Verder VA15 Non-metallic Air-Operated Double Diaphragm Pump 1/2 in.Positive Displacement PumpsView details
Verder VA10 Non-metallic Air-Operated Double Diaphragm Pump 3/8 in.Positive Displacement PumpsView details
Verder VA08 Non-metallic Air-Operated Double Diaphragm Pump 1/4 in.Positive Displacement PumpsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Verder VA08 Non-metallic Air-Operated Double Diaphragm Pump 1/4 in. Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Verder is a Dutch family-owned group of pump and laboratory equipment companies, founded in 1959 by André Verder in Vleuten, near Utrecht, as a distributor of industrial pumps. It expanded into Belgium in 1970 and Germany in 1973 and later developed its own pump brands, including VERDERAIR diaphragm pumps and Verderflex peristaltic pumps. The group is run by his son Andries Verder and has sales offices in 24 countries.

Seven Star LLC lists Verder pumps from both families and supplies them, with wear parts such as hoses and diaphragms, to process plants in Oman.

Verder company profile

Founded 1959, Vleuten, Netherlands
Founder André Verder
Ownership Verder family
Divisions Verder Liquids and Verder Scientific
Product families VERDERAIR air-operated double diaphragm pumps, VERDERAIR PURE chemical pumps, Verderflex Dura hose pumps and Rapide tube pumps, Packo centrifugal pumps

Milestones

  • 1959: André Verder starts the business.
  • 1970: Verder opens its first foreign subsidiary in Belgium.
  • 1989: Verder acquires Retsch.

Verderflex and Verderair pumps listed here

The Verderflex Dura 35 is a peristaltic hose pump, and the Verderflex Rapide is a low-pressure peristaltic tube pump from the same family. The Verder VA25 is a Verderair air-operated double diaphragm pump. The VA25 is offered in metallic and non-metallic versions.

Where Verder pumps are used

In hose pumps such as the Dura, the liquid touches only the hose. Diaphragm pumps such as the VA25 are used for liquid transfer and for emptying containers.

Verder products we list

Family Examples
Pumps VA25 Air-Operated Double Diaphragm Pump, VERDERAIR PURE VA-P40 Chemical Diaphragm…, VERDERAIR VA50 Metallic Air-Operated Dou…, Verderflex Dura 35 Peristaltic Hose Pump, Verderflex Rapide Peristaltic Tube Pump

Ordering Verder pumps and parts: what we need

Send the pump type code and serial number from the nameplate. For a Verderflex hose, state the pump size and the hose material. For a Verderair pump, state the body, diaphragm, ball and seat materials. For a new pump, give the liquid, flow, pressure and temperature. We quote for buyers across the GCC.

Facts checked against Verder's own company roots page (verder.com), October 2026.

FAQ

Questions about the Verder VA08 Non-metallic Air-Operated Double

Answers from our engineering team on installation, compatibility and integration.

01Why can the Verder VA08 be mounted in any position?
Verder fits the VA08 with spring-operated Hastelloy check valves, so gravity is not needed to close them and the pump can be installed even upside down.
02What flow does the Verder VA08 deliver?
The VA08 delivers up to 5.02 US gpm at a maximum discharge pressure of 7 bar, with a dry suction lift of 2.5 m and a wet lift of 4.4 m.
03What are the connections of the Verder VA08?
Liquid connections are quarter inch BSP or NPT (code TX) and the air connection is quarter inch NPT, according to the Verder product properties.
04How much does the Verder VA08 weigh?
The datasheet gives 1.1 kg for acetal, 0.9 kg for polypropylene and 1.3 kg for the Kynar version, making it the lightest Verderair pump.
05What temperature and viscosity limits apply to the Verder VA08?
All internals are rated 0 to 82 degrees C, with a maximum recommended viscosity of 500 mPas and particles up to 1.5 mm.