Rittal KL 1503.510 terminal box, 300x200x120 mm, IP 66

The Rittal KL 1503.510 is a spray-finished sheet steel terminal box from the KL series. External dimensions are 300x200x120 mm (width x height x depth), the net weight is 2.673 kg and the stated protection category is IP 66. It is a mid-size terminal box, suited to a group of field cables, a pump or motor local terminal point, or a small relay and terminal-block assembly. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer; the product name and part number are used only to identify the item.

Reading the part number KL 1503.510

The KL prefix identifies the terminal box series. The four-digit number 1503 selects one size and one body configuration, and the suffix .510 is the catalogue variant used across the series. This is the version without a gland plate, which is the blank body that you drill or punch to suit your own cable layout; the stated protection category is IP 66, so any entry you cut has to be sealed to keep that rating. Because the size is fixed by the article number, compare the 300x200x120 mm footprint with the cable bend radius, terminal rail length and device spacing you need before ordering.

Technical specifications of KL 1503.510

Parameter Specification
Manufacturer / part number Rittal KL 1503.510
Material Enclosure: Sheet steel; Cover: Sheet steel, all-round foamed-in PU seal
Surface finish Enclosure and cover: Dipcoat primed, powder-coated on the outside,; textured paint
Colour RAL 7035
Supply includes Enclosure with cover; Quick-release fastener including plastic bushes
Dimensions Width: 300 mm; Height: 200 mm; Depth: 120 mm
Protection category to IEC 60 529 IP 66
Protection category NEMA NEMA 4
IK Code IK08
Material thickness – cover 1.25 mm
Material thickness – enclosure 1.25 mm
Basic material Sheet steel
Net weight 2.673 kg
Gross weight 2.873 kg

Construction and sealing of the KL body

The enclosure is a steel body with a sheet steel cover. The data sheet lists the cover with an all-round foamed-in polyurethane seal and a powder-coated, textured finish in RAL 7035 over a dip-coat primer. Wall thickness is stated as 1.25 mm for the enclosure, which gives the 300x200x120 mm body enough stiffness to hold its shape when the cover screws are tightened and the seal is compressed. The supply includes the enclosure with cover and the quick-release fasteners with plastic bushes, so the cover can be opened with a screwdriver and the screws stay captive in the cover.

The internal volume implied by the outer dimensions is roughly 7.2 litres, which is a quick way to judge whether terminals, ferrules and a bundle of cables will fit. As a rule, leave room for a bend radius of several cable diameters and for a clear zone around any gland so that the cable can be tightened without pulling on the conductors. Where the box will carry heat-producing devices, check the thermal limits of those devices rather than the enclosure alone.

How a KL terminal box KL 1503.510 is used in a plant

A terminal box collects field cables at a defined point, keeps connections dry and dust-tight and gives maintenance staff a labelled place to test and isolate circuits. The 300x200x120 mm format of KL 1503.510 is tall and almost square. In a typical build the installer fits a DIN rail or terminals inside, glands the incoming and outgoing cables, lands shields at the earthing point and marks the cover. Reserve some spare terminals for later changes, because adding a second box later is usually more costly than selecting the next size up now.

Where KL 1503.510 fits in the KL range and related parts

Neighbouring KL articles such as KL 1501.510, KL 1502.510, KL 1503.510, KL 1504.510, KL 1505.510, KL 1506.510, KL 1510.510, KL 1511.510, KL 1512.510, KL 1513.510 and KL 1514.510 share the same family design but change the width, height or depth. The with-gland-plate versions KL 1530.510 and KL 1540.510 are listed at IP 55. Typical accessories named for the series are the quick-release fastener, cover retainer, plastic cable gland plate, cover hinges and mounting plate. Always check the accessory data sheet for the exact article that matches your size.

Selection checklist for KL 1503.510

  • Confirm the footprint of 300x200x120 mm against the mounting wall, including space to swing the cover open and to remove the cable gland nuts.
  • Count terminals and add spare capacity; allow for DIN rail, marking strips and ferrule length.
  • Decide on the cable entry method: you will punch or drill the body, so choose a location that keeps swarf out of the interior and seal each entry.
  • Check the approvals listed for this exact article: Bureau Veritas, DNV, Lloyds Register, UL + C-UL (listed).
  • Check the material and coating against the surrounding atmosphere. Painted sheet steel is a standard choice for indoor and sheltered outdoor use; for strongly corrosive or washdown service ask about stainless steel alternatives.
  • Plan the earthing: the cover and body connect to the protective earth system according to the project specification.

Installation, commissioning and maintenance

Mount the box on a flat, rigid surface using the wall mounting brackets or the mounting holes in the rear. Use fixings suited to the base material and the 2.673 kg weight of the empty body. Prepare cable entries before fitting any terminals, so that metal chips cannot fall onto live parts. Fit glands that match the cable outer diameter and the required ingress rating, tighten them to the gland maker’s torque and leave a drip loop in the cable where practical.

Before energising, check each terminal for tightness, confirm the protective-earth connection of cover and body, and make sure the seal is clean, undamaged and seated. During planned shutdowns inspect the seal for hardening or cracks, look for corrosion at cut-outs, and retighten terminals, since thermal cycling can loosen screw connections. Photograph the wiring before work starts so that a technician can restore the layout.

Typical applications in Oman and the GCC

In oil and gas, power and water facilities across Oman and the GCC, terminal boxes such as KL 1503.510 are used at pump skids, valve stations, lighting and small-power points, instrument junctions and temporary construction power. High ambient temperature, fine desert dust and coastal humidity are the main stresses. The IP 66 rating protects against dust and water jets, but the box should still be shaded where possible, mounted with the cable entries facing downward, and kept away from direct splash or hot surfaces. Sheet steel with a powder-coated finish suits indoor plant rooms and sheltered outdoor locations, whereas severe salt-laden coastal areas call for extra review of coating and fixings.

Hazardous-area use is a separate topic: this KL article is not described in the data sheet as explosion-protected, so do not use it in classified zones unless a suitable certificate is in place for the specific installation.

Comparison of KL sizes

Article Width x height x depth (mm) Gland plate Protection
KL 1501.510 300 x 150 x 120 No IP 66
KL 1502.510 200 x 200 x 120 No IP 66
KL 1503.510 300 x 200 x 120 No IP 66
KL 1504.510 400 x 200 x 120 No IP 66
KL 1505.510 500 x 200 x 120 No IP 66
KL 1506.510 600 x 200 x 120 No IP 66
KL 1510.510 600 x 300 x 120 No IP 66
KL 1511.510 400 x 400 x 120 No IP 66
KL 1512.510 600 x 400 x 120 No IP 66
KL 1513.510 800 x 400 x 120 No IP 66
KL 1514.510 150 x 150 x 80 No IP 66
KL 1519.510 600 x 200 x 80 No IP 66
KL 1530.510 300 x 150 x 120 Yes IP 55
KL 1540.510 600 x 400 x 120 Yes IP 55

Information to send with an RFQ for KL 1503.510

  • Part number KL 1503.510 and the required quantity.
  • Number and diameter of cables and the glands you expect to need.
  • Installation environment: indoor, sheltered outdoor, near coast, dust level.
  • Required approvals or classification documents for the project.
  • Delivery location in Oman or the GCC and the required date.

Documents and quotation

The manufacturer data sheet for KL 1503.510 is attached on this page and lists the dimensions, materials and approvals for this article. Please check it against your drawings before ordering.

For a quotation send the part number KL 1503.510, the quantity, the delivery location in Oman or the GCC and any project requirements. Seven Star LLC will reply with availability and lead time.

Other Models in the Rittal Kl Range

Seven Star LLC supplies models from the Rittal Kl range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Rittal KL 1501.510 Terminal Box 300x150x120 mmSwitchgear, Enclosures & DistributionView details
Rittal KL 1502.510 Terminal Box 200x200x120 mmSwitchgear, Enclosures & DistributionView details
Rittal KL 1503.510 Terminal Box 300x200x120 mmSwitchgear, Enclosures & DistributionYou are viewing this model
Rittal KL 1504.510 Terminal Box 400x200x120 mmSwitchgear, Enclosures & DistributionView details
Rittal KL 1505.510 Terminal Box 500x200x120 mmSwitchgear, Enclosures & DistributionView details
Rittal KL 1506.510 Terminal Box 600x200x120 mmSwitchgear, Enclosures & DistributionView details
Rittal KL 1510.510 Terminal Box 600x300x120 mmSwitchgear, Enclosures & DistributionView details
Rittal KL 1511.510 Terminal Box 400x400x120 mmSwitchgear, Enclosures & DistributionView details
Rittal KL 1512.510 Terminal Box 600x400x120 mmSwitchgear, Enclosures & DistributionView details
Rittal KL 1513.510 Terminal Box 800x400x120 mmSwitchgear, Enclosures & DistributionView details
Rittal KL 1514.510 Terminal Box 150x150x80 mmSwitchgear, Enclosures & DistributionView details
Rittal KL 1519.510 Terminal Box 600x200x80 mmSwitchgear, Enclosures & DistributionView details
Rittal KL 1530.510 Terminal Box 300x150x120 mmSwitchgear, Enclosures & DistributionView details
Datasheets & Documents
  • PDF Datasheet Rittal KL 1503.510 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Rittal is a German manufacturer of enclosures, power distribution, climate control and IT infrastructure, founded in 1961 by Rudolf Loh in Rittershausen, Hesse, as Rudolf Loh Elektrogerätebau. In its first year it launched the first standard enclosure, built in series and available from stock instead of made to order. Rittal is headquartered in Herborn and belongs to the family-owned Friedhelm Loh Group.

Seven Star LLC is an independent supplier in Muscat. We list Rittal enclosures, cooling units and power distribution products for panel builders and maintenance teams in Oman and the GCC.

Rittal company profile

Founded 1961, Rittershausen (Dietzhölztal), Germany, by Rudolf Loh
Headquarters Herborn, Hesse, Germany
Ownership Friedhelm Loh Group (Loh family); sister companies include Eplan and Cideon
Idea Standard enclosures in series production, available from stock
Product families VX25 and AX/KX enclosures, TS 8 baying systems, Blue e+ cooling units and fan-and-filter units, RiLine busbar systems, IT racks and data centre modules

Milestones

  • 1961: Rudolf Loh founds the company and launches the first standard enclosure.
  • 1969: The company takes the Rittal name, according to Rittal.
  • 2021: Rittal marks 60 years.

Rittal product series

Enclosures include the TS 8 free-standing bayable system, AE compact enclosures such as the AE 1380.500 and AE 1034.500, and the CS outdoor wall-mounted enclosure. For hazardous areas there are the KEL 9404.600 stainless steel and AX 9206.100 plastic Ex enclosures. Power distribution is covered by the VX25 Ri4Power switchgear system and its 185 mm busbar system.

Climate control includes Blue e+ wall-mounted cooling units, the TopTherm Blue e SK 3273.500 roof-mounted unit and the LCP Inline CW liquid cooling package for IT racks.

Where Rittal products are used

Machine and process control panels, motor control and power distribution switchboards, outdoor telecom and utility cabinets, junction boxes in hazardous areas and IT racks. In the Gulf, cabinet cooling is often the deciding factor for reliable electronics.

Rittal products we list

Family Examples
Automation Accessories AE 1034.500 Compact Enclosure 300 x 400…, AE 1380.500 Compact Enclosure 380 x 380…, AX 9206.100 Ex Plastic Enclosure 600 x 6…, CS 9791.015 Outdoor Wall-Mounted Enclosure, KEL 9404.600 Ex Stainless Steel Enclosur…, VX25 Ri4Power 185 mm Busbar System, VX25 Ri4Power Switchgear and Power Distr…
Enclosure Climate Control Blue e+ Wall-Mounted Enclosure Cooling U…
Cooling SK 3273.500 TopTherm Blue e Roof-Mounted…
Switchgear, Enclosures & Distribution TS 8 Free-Standing Enclosure System

Ordering Rittal products: what we need

Rittal parts are ordered by a seven-digit model number such as 9404.600. Send that number, or the width, height and depth, material, protection category and door arrangement. For cooling units add the cooling output, rated voltage and mounting cut-out of the unit being replaced; for Ex enclosures, the zone and marking required.

Facts checked against Rittal's own company pages and Friedhelm Loh Group material, October 2026.

FAQ

Questions about the Rittal KL 1503.510 Terminal Box 300x200x120 mm

Answers from our engineering team on installation, compatibility and integration.

01What are the dimensions and weight of KL 1503.510?
The outer dimensions are 300x200x120 mm (width x height x depth) and the net weight is 2.673 kg according to the manufacturer data sheet. Always confirm clearances for doors, covers and cable entries on your drawing.
02What protection category does KL 1503.510 have?
The data sheet states IP 66 for this article. This describes protection against solid objects and water under the standard test conditions, and it only holds while doors, covers, seals and cable entries are correctly closed and fitted.
03Can KL 1503.510 be used in a hazardous area?
The data sheet we hold does not describe this article as explosion-protected, so it should not be used in classified zones. For those areas a certified enclosure is required, and the certificate must be checked for the specific installation.
04Which documents are available for KL 1503.510?
The manufacturer data sheet for this article, with dimensions, materials and the approvals listed for it, is attached on this page. Send the part number with your RFQ if you need other documents and we will confirm what is available.
05Does Seven Star LLC supply KL 1503.510 in Oman?
Seven Star LLC is an independent supplier in Muscat serving customers in Oman and the GCC, and is not affiliated with the manufacturer. Send the part number KL 1503.510, quantity and delivery location, and we will respond with availability and lead time.