Brand: Pizzato
Pizzato CS MP206M0 Programmable Safety Module, 12 Outputs
Description
Overview
Safety is not only about switching things off. Operators and maintenance staff also want to know which door is open, which e-stop was pressed and why the line will not restart. The Pizzato CS MP206M0 is the Gemnis programmable safety module that puts the emphasis on that information. It carries 8 safety inputs, 4 test outputs, 4 PNP safety outputs and as many as 12 signalling outputs, all in a 45 mm wide housing programmed through USB with Gemnis Studio. With Maximum SIL 3, PL e and category 4 limits and a response time below 30 ms, it can be both the logic of the safety function and the source of the diagnostic lamps. Seven Star LLC is an independent supplier serving Oman and the GCC.
Data of the Pizzato CS MP206M0
| Property | Value |
|---|---|
| Safety inputs | 8 |
| Test outputs | 4 |
| PNP safety outputs (OS) | 4 |
| Signalling outputs (O) | 12 |
| MTTFD | 3314 years |
| PFHD | 1.09E-09 per hour |
| Mission time | 20 years |
| System response time | Below 30 ms |
| Dimensions | 111.5 x 45 x 99 mm |
| Supply | 24 Vdc, plus or minus 15 percent, below 3 W without load |
| Signalling output rating | Semiconductor, protected electronically |
| Total Ox and Tx current | 0.5 A maximum |
| Interface | USB, programming with Gemnis Studio |
| Housing | PA 66 V0, IP40, terminals IP20 |
| Ambient | 0 to plus 55 degrees Celsius |
Twelve signals instead of a lamp panel
A conventional relay solution needs one auxiliary contact for each indication and a separate panel of lamps. Here, the program can switch any of the twelve signalling outputs according to the state of an input, a function block or an internal fault. Typical uses are one lamp per guarded door, a lamp for each e-stop station, a lamp for the restart request and an output to the PLC for general fault. The catalogue also lists a SERIAL function block that lets the module exchange its state with a PLC. The signalling outputs are not safety-related and are not to be used for safety functions, so the safety logic is still carried by the four PNP outputs.
How Pizzato CS MP206M0 differs from other 45 mm Gemnis codes
- The CS MP201M0 has 8 inputs and 8 test outputs with 3NO relay contacts and 4 signalling outputs, so it fits when relay contacts are needed.
- The CS MP202M0 has 16 inputs and 4 signalling outputs.
- The CS MP205M0 combines 4 standard inputs, 4 decoupled inputs and 4 frequency inputs, with 4 signalling outputs.
- The CS MP208M0 has 16 inputs, 8 PNP safety outputs and no signalling outputs.
- This code has the highest MTTFD in the group of codes compared here, 3314 years, the lowest PFHD of 1.09E-09 per hour, and the most signalling outputs, 12.
Where it is applied
Machines that are used by many operators with little training benefit most: bottling plants, plastic extrusion lines, large cutting machines and automated storage systems. In Oman, where installations are often operated in two or three shifts and maintained by external service teams, a clear indication of the cause of a stop saves long search times. The module can also drive a beacon column with different signals for open door, e-stop and ready to restart, which is a common request from end users of imported equipment.
Designing the indication scheme
Having twelve outputs does not mean all of them should be used. A readable scheme is more valuable than a crowded one. Decide first which states the operator really needs: guard open, emergency stop active, waiting for reset, safety function active and module fault. Give each state a lamp colour or a beacon segment, use the same scheme on all machines of the plant and write it in the operator manual. Then assign one signalling output per state and keep two or three outputs free for later changes. Because the logic is a program, a new indication needs no new wiring in the cabinet, only a lamp, a cable and a modification of the project file, followed by the validation of the changed part. Remember that signalling outputs carry only small currents, so a lamp or a relay with a low coil current is appropriate, and heavier indicators such as horns or large beacons should be driven through an interposing relay.
Commissioning steps
- Install Gemnis Studio, create a project for the Pizzato CS MP206M0 and define the eight inputs with their sensor types.
- Allocate the four PNP safety outputs to the safety functions, such as drive enable and valve enable.
- Allocate signalling outputs to the lamp or PLC channels you need.
- Simulate and then load the program via the USB port.
- Validate each function on the machine and file the connection report and the program report.
Electrical details for wiring
Input circuits are 24 V at 5 mA, with 0 to 8 V as off and 12 to 24 V as on, a minimum signal of 10 ms and filtering of interference up to 0.4 ms. Maximum input resistance is 100 ohm and capacitance is limited to 470 nF to ground and between conductors. Use copper conductors of 30 to 12 AWG, tightening the terminal screws to 5 to 7 lb in. The 24 Vdc supply has a PTC protection with a holding current of 1.5 A, and the module performs a self-test of less than 2 seconds at start-up.
Maintenance
Archive the project file and keep its password with the machine records. After any change, run the validation again and document the date. Because the signalling outputs are likely to drive lamps or PLC inputs, check them during every proof test as well, even though they are not part of the safety chain. If the module is replaced, load the stored program and test all functions.
Related items you may also need: Pizzato FR 693 Safety Switch with Separate Actuator, 1NO+1NC | Pizzato FD 1001 Metal Position Switch with Plunger | Pizzato FK 301 Position Switch with Plunger, Snap Action | All Pizzato products.
Points to confirm for the Pizzato CS MP206M0
- If the Pizzato CS MP206M0 is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
- For each Pizzato CS MP206M0 request we confirm the exact code, new or surplus condition and lead time in writing.
- Dimensions, ratings and connection data for the Pizzato CS MP206M0 are in the datasheet attached to this page.
- The Pizzato CS MP206M0 belongs to our safety switches & guard locking range and can be delivered to Muscat, Sohar, Duqm and other GCC locations.
- Plants that run the Pizzato CS MP206M0 on critical service often hold a spare unit in the store.
Documents and quotation
The Pizzato catalogue chapter for the CS MP modules is attached to this page and includes the table of modules, technical data and terminal diagrams. To request a quotation, send an RFQ with Pizzato CS MP206M0, the number of pieces, your delivery destination in Oman or the GCC and any accessories you need.
Other Models in the CS MP Range
Seven Star LLC supplies models from the CS MP range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Pizzato CS MP201M0 Programmable Safety Module, Gemnis | Safety Switches & Guard Locking | View details |
| Pizzato CS MP202M0 Programmable Safety Module, 16 Inputs | Safety Switches & Guard Locking | View details |
| Pizzato CS MP206M0 Programmable Safety Module, 12 Outputs | Safety Switches & Guard Locking | You are viewing this model |
Datasheets & Documents
- Datasheet Pizzato CS MP206M0 Programmable Safety Module, 12 Outputs Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pizzato Elettrica is an Italian maker of position switches and safety devices, founded in 1984 as a manufacturer of position switches and based in Marostica, near Vicenza. It took the name Pizzato Elettrica in 1988 and added safety modules around 2002. The company designs and assembles its products in Marostica, where it opened a new 25,000 m² headquarters in 2019.
Seven Star LLC is an independent supplier in Muscat. We list Pizzato switches for machine builders and maintenance teams in Oman and the GCC.
Pizzato company profile
| Founded | 1984, Italy |
|---|---|
| Headquarters | Marostica, Italy |
| Name since | 1988 |
| Catalogue | More than 7,000 standard products |
| Product families | FR, FD and FK position switches, NG and NS safety interlocks, NX RFID safety switches, safety modules, foot switches |
Milestones
- 1984: Pizzato is founded.
- 1988: The company becomes Pizzato Elettrica.
- 2019: A new headquarters opens in Marostica.
Pizzato product series
Position switches include the FD 1001 metal switch with plunger, the FK 301 switch with plunger and snap action contacts, and the FR 1007 switch with adjustable roller lever.
Switches are chosen by the housing (metal or technopolymer), actuator, contact block and electrical connection. Snap action contacts switch quickly regardless of actuator speed, and positive opening contacts are used in safety circuits.
Plunger actuators suit short, straight movements against a cam or stop, while adjustable roller levers let the operating point be set on site and suit cams and moving parts that pass the switch. Metal housings stand up to heavy duty and impacts, and each data sheet states the IP rating, mechanical life and operating temperature range.
Where Pizzato switches are used
End of travel detection on machines, conveyors, doors and guards, cranes and lifting equipment.
Pizzato products we list
| Family | Examples |
|---|---|
| Automation Accessories | FD 1001 Metal Position Switch with Plunger, FK 301 Position Switch with Plunger, FR 1007 Position Switch |
Ordering Pizzato switches: what we need
Send the full article code, or the actuator type, contacts, housing and cable entry.
Facts checked against Pizzato's own timeline and EtherCAT member profile, October 2026.
Browse Pizzato products by category: Automation Accessories.
FAQ
Questions about the Pizzato CS MP206M0 Programmable Safety Module, 12
Answers from our engineering team on installation, compatibility and integration.
01How many signalling outputs does the Pizzato CS MP206M0 have?
It has 12 signalling outputs, together with 8 safety inputs, 4 test outputs and 4 PNP safety outputs.
02What safety figures does the CS MP206M0 list?
MTTFD is 3314 years, PFHD is 1.09E-09 per hour and the mission time is 20 years, within Maximum SIL 3, PL e and category 4.
03Does the CS MP206M0 have relay outputs?
No, its safety outputs are four PNP semiconductor outputs; the catalogue lists no relay contacts for this code.
04How fast does the CS MP206M0 respond?
The system response time is below 30 ms.
05What do I need to program the CS MP206M0?
A PC with Windows 10 or later running Gemnis Studio, plus a USB connection to the module, after registering on the manufacturer website.