Brand:

Pizzato CS FS-14V120 Long-Delay Safety Timer, 120 Vac

Description

Overview

Some hazards take minutes, not seconds, to go away: a large centrifuge spinning down, a hot press cooling its tooling, a high-inertia fan or a vessel holding pressure. The Pizzato CS FS-14V120 is the long-delay member of the Pizzato CS FS-1 safety timer series. Code 14 selects an adjustable delay at energising of 30 to 300 seconds in steps of 30 seconds, the 120 selects a 120 Vac supply, and the V means screw terminals. The module closes one normally open safety contact after the time has run and offers two normally closed signalling contacts. Seven Star LLC is an independent supplier serving Oman and the GCC.

Technical table for Pizzato CS FS-14V120

Item Catalogue data
Series CS FS-1 safety timer
Time setting 30 to 300 s, steps of 30 s (code 4)
Supply 120 Vac, 50 to 60 Hz, plus or minus 15 percent
Consumption Below 5 VA
Contacts 1NO safety, 2NC auxiliary, forcibly guided
Contact material Silver alloy
Safety limits Up to SIL 3 and PL e; category 4 depends on circuit structure
Release without supply Below 60 ms
Switching capacity 230/240 Vac and 300 Vdc maximum
Categories AC-15 3 A at 230 V; DC-13 4 A at 24 V
Thermal current 6 A per branch; total squared current 36 A2
Minimum load 10 mA; contact resistance up to 100 milliohm
Housing PA 66 V0; IP40; terminals IP20
Operating temperature Minus 25 to plus 55 degrees Celsius
Approvals IMQ CP 432 DM, UL E131787, CCC, EAC

Reading the long time scale

With steps of 30 seconds the dial positions correspond to 30, 60, 90 and so on up to 300 seconds, so a delay of 2 minutes is a clean setting while 100 seconds is not. That granularity is perfectly adequate for processes that take minutes, but it is not suited to machines that stop in a few seconds, where a CS FS-11 code with 0.3 second steps is the better fit. The same logic applies when comparing with the 12 and 13 codes, which stop at 10 seconds and 30 seconds. The long scale also has a consequence for the commissioning test: a measured delay of five minutes needs patience, and the test must be repeated after any change of the dial.

Situations where Pizzato CS FS-14V120 is the right choice

Consider a chemical mixing vessel with an agitator that coasts for three minutes and a door that must stay locked until the blades have stopped. Or a thermoforming line whose heated platens need time to cool below a safe contact temperature before the cover can be opened. Or a large centrifugal dryer in a laundry or food plant. In each case the machine builder knows a conservative time from tests, sets the dial slightly above it, and uses the module to give the release command to the door lock or the access valve. Gulf conditions matter here: high ambient temperatures lengthen cooling times, so the measurement should be made in summer conditions.

How CS FS-14V120 differs from sister codes

  • CS FS-11 codes cover 0.3 to 3 seconds, CS FS-12 covers 1 to 10 seconds, CS FS-13 covers 3 to 30 seconds, and this code covers 30 to 300 seconds.
  • The 024 variants run on 24 Vac/dc with below 2 W on dc; this one runs on 120 Vac below 5 VA.
  • The 230 variants use 230 Vac and otherwise match this module.
  • Connector versions M and X replace the fixed screw terminals of this V code.

Wiring and installation

Fit the module on a DIN rail and supply it with 120 Vac through the circuit that represents the release request. Use the normally open contact in the release circuit of the lock, valve or brake, and the signalling contacts for the PLC. The external fuse is 4 A. Because the supply is a line voltage, apply the clearances of the catalogue, with pollution degree 3 outside and 2 inside the housing, and wire with copper conductors of 30 to 12 AWG for the UL rating. Terminal tightening torque of 5 to 7 lb in is given in the notes.

Documenting the delay for auditors

A long delay deserves a written justification. Note the test conditions under which the stopping or cooling time was measured, including load, temperature, brake condition and the person who performed the test, and add a safety margin that the risk assessment accepts. Keep the number next to the dial setting in the machine documentation. When an inspector or an insurer asks why the door stays locked for five minutes, the answer should be a measured value, not an estimate, and the same record shows later whether any change of process has made the delay too short.

Interaction with the rest of the safety circuit

A timer module is usually one link in a chain. Upstream there is a base safety relay or a safety PLC that detects the stop request, and downstream there is a lock, a valve or a contactor that acts on the release. The timer should be placed so that a failure of the supply or of the wiring leaves the lock closed, because the safe state is the open safety contact. The catalogue says the release time without supply is below 60 ms, which means that the safety contact opens almost at once when power is lost and leaves the downstream release circuit de-energised. Do not use the signalling contacts for safety functions.

Checks and service

Test the delay by timing it, and then verify that the safety contact stays open before that moment and closes at it. Repeat the check each year and after maintenance. If the real hazard time grows, for instance because of a heavier load or a changed brake, review the dial. When replacing the unit, copy the setting and then time it again, since the dial position is the only parameter of the module.

Related items you may also need: Pizzato FR 1007 Position Switch, Adjustable Roller | Pizzato FD 1001 Metal Position Switch with Plunger | Pizzato FK 301 Position Switch with Plunger, Snap Action | All Pizzato products.

Before you order the Pizzato CS FS-14V120

  • To avoid a wrong delivery, compare the code on the nameplate of the installed unit with the Pizzato CS FS-14V120 code on this page.
  • The quotation for the Pizzato CS FS-14V120 states the confirmed code, the condition of the unit and the lead time to site.
  • The attached manufacturer datasheet covers the Pizzato CS FS-14V120 ratings, dimensions and installation details.
  • Delivery of the Pizzato CS FS-14V120 is arranged to project sites in Oman and across the GCC, alongside the rest of our safety switches & guard locking range.
  • A spare Pizzato CS FS-14V120 on the shelf is a simple way to protect critical service from long lead times.

Documents and quotation

The manufacturer catalogue sheet of the CS FS-1 series is included with this page and gives the technical data, code structure and diagrams. For a quotation, please send an RFQ stating Pizzato CS FS-14V120, the quantity and the delivery address in Oman or the GCC, and add the time you need to achieve so that we can advise on the right range.

Other Models in the CS FS Range

Seven Star LLC supplies models from the CS FS range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Pizzato CS FS-11V024 Safety Timer, Delay at EnergisingSafety Switches & Guard LockingView details
Pizzato CS FS-14V120 Long-Delay Safety Timer, 120 VacSafety Switches & Guard LockingYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Pizzato CS FS-14V120 Long-Delay Safety Timer, 120 Vac Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pizzato Elettrica is an Italian maker of position switches and safety devices, founded in 1984 as a manufacturer of position switches and based in Marostica, near Vicenza. It took the name Pizzato Elettrica in 1988 and added safety modules around 2002. The company designs and assembles its products in Marostica, where it opened a new 25,000 m² headquarters in 2019.

Seven Star LLC is an independent supplier in Muscat. We list Pizzato switches for machine builders and maintenance teams in Oman and the GCC.

Pizzato company profile

Founded 1984, Italy
Headquarters Marostica, Italy
Name since 1988
Catalogue More than 7,000 standard products
Product families FR, FD and FK position switches, NG and NS safety interlocks, NX RFID safety switches, safety modules, foot switches

Milestones

  • 1984: Pizzato is founded.
  • 1988: The company becomes Pizzato Elettrica.
  • 2019: A new headquarters opens in Marostica.

Pizzato product series

Position switches include the FD 1001 metal switch with plunger, the FK 301 switch with plunger and snap action contacts, and the FR 1007 switch with adjustable roller lever.

Switches are chosen by the housing (metal or technopolymer), actuator, contact block and electrical connection. Snap action contacts switch quickly regardless of actuator speed, and positive opening contacts are used in safety circuits.

Plunger actuators suit short, straight movements against a cam or stop, while adjustable roller levers let the operating point be set on site and suit cams and moving parts that pass the switch. Metal housings stand up to heavy duty and impacts, and each data sheet states the IP rating, mechanical life and operating temperature range.

Where Pizzato switches are used

End of travel detection on machines, conveyors, doors and guards, cranes and lifting equipment.

Pizzato products we list

Family Examples
Automation Accessories FD 1001 Metal Position Switch with Plunger, FK 301 Position Switch with Plunger, FR 1007 Position Switch

Ordering Pizzato switches: what we need

Send the full article code, or the actuator type, contacts, housing and cable entry.

Facts checked against Pizzato's own timeline and EtherCAT member profile, October 2026.

FAQ

Questions about the Pizzato CS FS-14V120 Long-Delay Safety Timer, 120

Answers from our engineering team on installation, compatibility and integration.

01What time range does the Pizzato CS FS-14V120 cover?
Delay code 4 provides an adjustable delay at energising of 30 to 300 seconds, in steps of 30 seconds.
02What supply does the CS FS-14V120 need?
It runs on 120 Vac at 50 to 60 Hz with plus or minus 15 percent tolerance and consumes below 5 VA.
03How many safety contacts does the CS FS-14V120 have?
One normally open safety contact, together with two normally closed signalling contacts, all forcibly guided.
04When would I choose the CS FS-14V120 over the CS FS-11 codes?
When the hazard lasts minutes, such as a coasting centrifuge or cooling tooling, because this code reaches 300 seconds while code 1 stops at 3 seconds.
05What are the contact ratings of the CS FS-14V120?
AC-15 at 230 V and 3 A, DC-13 at 24 V and 4 A, thermal current 6 A per branch and total squared current 36 A2.