Brand:

Pizzato CS ME-01V024 Safety Expansion Module, 5NO+1NC

Description

Overview

Safety modules rarely have as many contacts as a real machine needs. A base module may offer two or three safety outputs, while the drive, the brake, the hydraulic valves and the lubrication pump each want their own contact. The Pizzato CS ME-01V024 solves this by multiplying contacts: it is a Pizzato expansion module with five normally open safety contacts, one normally closed signalling contact and one normally closed feedback contact. It follows the base module, which keeps all the diagnostic work, and it can be driven by one or two channels. This code uses the 24 V ac/dc supply with screw terminals. Seven Star LLC is an independent supplier serving Oman and the GCC.

What the expansion module does and does not do

The module contains forcibly guided relays and nothing else that makes decisions. It does not monitor emergency stop buttons or guard switches by itself in the way a base module does. In a typical circuit its control input is fed from an output of a base module, and the relays then repeat the state of that output on five contacts. The catalogue lists a normally closed feedback contact alongside the signalling contact, and the usual purpose of such a contact is to let the base module confirm, through its restart loop, that the expansion relays have really dropped before a new start is allowed. The catalogue states that the safety category is the one of the base module, up to category 4, which means the expansion adds contacts without lowering the level when it is connected correctly.

Technical data for Pizzato CS ME-01V024

Characteristic Datasheet value
Type Expansion module with output contacts
Safety contacts 5NO, forcibly guided, silver alloy
Auxiliary contacts 1NC signalling and 1NC feedback
Supply, code 024 24 Vac/dc, 50 to 60 Hz, plus or minus 15 percent
Power consumption Below 5 VA on ac, below 2 W on dc
Control One or two channels, opposite potentials allowed
Response time tA Below 40 ms
Release time without supply Below 50 ms
Maximum switching voltage 230/240 Vac, 300 Vdc
Utilisation categories AC-15 230 V 3 A; DC-13 24 V 4 A
Thermal current 6 A per branch, total squared current 72 A2
Minimum current 10 mA
Contact resistance Up to 100 milliohm
Fuse 4 A external
Safety limits Up to SIL 3, PL e, category 4 depending on the base module
Ambient temperature Minus 25 to plus 55 degrees Celsius
Housing PA 66 V0, IP40, terminals IP20, design A

Counting contacts: how Pizzato CS ME-01V024 compares

A quick way to place this code in the range is to count its safety contacts. A CS DM-01 two-hand module offers three, a CS AT-0 timed module offers two instantaneous plus two delayed, and a CS FS-1 timer offers one. The CS ME-01 gives five at once, which is more than any of them, and it can be cascaded: one base module can drive several expansion modules, within the limits of its output rating and the response time budget of the application. The 024 code is the only supply listed in the catalogue sheet for this series. The connection style is chosen with V for screw terminals, M for a plug-in connector with screw terminals, and X for a plug-in connector with spring terminals.

Where it is used

Large machines in Omani industry, such as bottling lines, palletising cells, injection moulding machines and gantry cranes in workshops, have safety functions that must disconnect many loads at once. Typical examples include isolating three motor contactors, a hydraulic valve, a pneumatic dump valve and a lubrication feed from one emergency stop. Instead of buying a larger base module, designers fit the Pizzato CS ME-01V024 next to the base relay, which shortens the delivery time and keeps spares simple. Panel shops serving oil and gas contractors also use it in packaged skids where the main safety relay is in a control room and the expansion sits near the loads.

Wiring principles

  1. Connect the supply to A1 and A2 within 24 V plus or minus 15 percent.
  2. Control the expansion inputs from the output of the base module, never from a bare switch, if the base module performs the diagnostics.
  3. Pass the feedback contact into the start circuit of the base module so that a welded contact prevents the next start.
  4. Protect the output circuit with a 4 A fuse as stated in the data.
  5. Keep the load current within the sum of squared currents limit of 72 A2 for all five contacts.

Planning the contact budget

Before ordering, list every load that must be switched by the safety function and note its type: contactor coil, solenoid valve, brake, signal lamp or PLC input. Divide them into those that need a safety contact and those that only need information. Safety loads go on the five normally open contacts, information goes on the normally closed signalling contact, and if the list is longer than five, a second expansion module can be added. Do not parallel contacts to carry more current, because the sum of squared currents is limited by the data sheet and uneven sharing may overload one branch.

Maintenance and spares

Forcibly guided relays have a finite electrical life, listed as over 100,000 operating cycles at rated load, against over 10 million mechanical cycles. Where a contact switches an inductive load such as a contactor coil frequently, use suppression and replace the module before the end of its electrical life. At every proof test, trip the base module and observe that all five contacts open and that the feedback contact closes. Holding a spare in the store is simple, because the module has no adjustments and no software. When you order it, quote the full code including the terminal letter, so that the replacement matches the plug-in or screw terminal style already used in the cabinet, and keep the old module until the new one has passed the proof test.

Related items you may also need: Pizzato FK 301 Position Switch with Plunger, Snap Action | Pizzato FR 693 Safety Switch with Separate Actuator, 1NO+1NC | Pizzato FD 1001 Metal Position Switch with Plunger | All Pizzato products.

Pizzato CS ME-01V024 ordering checklist

  • When the Pizzato CS ME-01V024 replaces an installed unit, check the existing nameplate against the code on this page before ordering.
  • Every enquiry for the Pizzato CS ME-01V024 is answered with a written confirmation of the code, condition and expected lead time.
  • Use the attached datasheet to check the Pizzato CS ME-01V024 ratings, dimensions and connection details against your drawings.
  • We supply the Pizzato CS ME-01V024 as part of our safety switches & guard locking range to plants in Oman and the GCC.
  • For critical duty, keeping one Pizzato CS ME-01V024 as a site spare shortens downtime after a failure.

Documents and quotation

The Pizzato catalogue sheet for the CS ME-01 expansion module is attached to this page, with the technical data, code structure and wiring diagrams. To request a quotation send an RFQ with Pizzato CS ME-01V024, the quantity, the base module it will be paired with and the delivery location in Oman or the GCC, so that we can check that the pairing is sensible and quote both items together.

Datasheets & Documents
  • PDF Datasheet Pizzato CS ME-01V024 Safety Expansion Module, 5NO+1NC Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pizzato Elettrica is an Italian maker of position switches and safety devices, founded in 1984 as a manufacturer of position switches and based in Marostica, near Vicenza. It took the name Pizzato Elettrica in 1988 and added safety modules around 2002. The company designs and assembles its products in Marostica, where it opened a new 25,000 m² headquarters in 2019.

Seven Star LLC is an independent supplier in Muscat. We list Pizzato switches for machine builders and maintenance teams in Oman and the GCC.

Pizzato company profile

Founded 1984, Italy
Headquarters Marostica, Italy
Name since 1988
Catalogue More than 7,000 standard products
Product families FR, FD and FK position switches, NG and NS safety interlocks, NX RFID safety switches, safety modules, foot switches

Milestones

  • 1984: Pizzato is founded.
  • 1988: The company becomes Pizzato Elettrica.
  • 2019: A new headquarters opens in Marostica.

Pizzato product series

Position switches include the FD 1001 metal switch with plunger, the FK 301 switch with plunger and snap action contacts, and the FR 1007 switch with adjustable roller lever.

Switches are chosen by the housing (metal or technopolymer), actuator, contact block and electrical connection. Snap action contacts switch quickly regardless of actuator speed, and positive opening contacts are used in safety circuits.

Plunger actuators suit short, straight movements against a cam or stop, while adjustable roller levers let the operating point be set on site and suit cams and moving parts that pass the switch. Metal housings stand up to heavy duty and impacts, and each data sheet states the IP rating, mechanical life and operating temperature range.

Where Pizzato switches are used

End of travel detection on machines, conveyors, doors and guards, cranes and lifting equipment.

Pizzato products we list

Family Examples
Automation Accessories FD 1001 Metal Position Switch with Plunger, FK 301 Position Switch with Plunger, FR 1007 Position Switch

Ordering Pizzato switches: what we need

Send the full article code, or the actuator type, contacts, housing and cable entry.

Facts checked against Pizzato's own timeline and EtherCAT member profile, October 2026.

FAQ

Questions about the Pizzato CS ME-01V024 Safety Expansion Module,

Answers from our engineering team on installation, compatibility and integration.

01How many safety contacts does the Pizzato CS ME-01V024 have?
It provides five normally open safety contacts, plus one normally closed signalling contact and one normally closed feedback contact.
02Does the CS ME-01V024 work on its own?
No, it is an expansion module that follows a base safety module; its safety category depends on the base module, up to category 4.
03What supply does the CS ME-01V024 use?
Only 24 Vac/dc at 50 to 60 Hz is listed, with plus or minus 15 percent tolerance and consumption below 5 VA ac or below 2 W dc.
04How quickly do the CS ME-01V024 contacts react?
Response time tA is below 40 ms, and release time with the supply removed is below 50 ms.
05What current can the CS ME-01V024 contacts carry?
Thermal current is 6 A per branch with AC-15 3 A at 230 V and DC-13 4 A at 24 V, and the total squared current is 72 A2.