Brand:

Magnetrol Z30-9180-001 HART Wiring Board for E4 Modulevel, Pulsar R86

Description

Magnetrol Z30-9180-001 overview: wiring board

The Magnetrol Z30-9180-001 is the HART wiring board in the transmitter head. It belongs to the E4 Modulevel displacer level transmitter, and it appears in the replacement parts section of the manufacturer instruction manual 48-636. Maintenance teams search for spare parts by this exact number because the same product family has many variants, and the wrong board, kit or displacer can leave a loop out of service.

The picture on this page shows the E4 Modulevel displacer level transmitter that the Magnetrol Z30-9180-001 fits. It is the manufacturer product image for the family and not a close-up of the wiring board itself. Every value on this page comes from the manufacturer catalog and manual for that family, and where a value is not published there we have left it out instead of guessing.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list Z30-9180-001 so that buyers can quote the number exactly as it appears in the manual, and we confirm availability against your quotation request.

Key features of Z30-9180-001

  • Exact manufacturer part number Z30-9180-001 for the wiring board.
  • Function: the HART wiring board in the transmitter head.
  • Host product: E4 Modulevel displacer level transmitter, described by the manufacturer as a loop-powered, two-wire displacer transmitter that converts buoyancy changes into a 4 to 20 mA HART signal through an LVDT.
  • Listed in manual 48-636, which is the reference for fitting and for the model code digits that select the part.
  • Quoted against the model number and serial number of your instrument so the variant can be checked.

Technical specifications for Z30-9180-001

The first table records what the manual states about the part itself. The second table gives the main data of the host instrument from the catalog, which helps confirm that the part suits the installation. No pricing appears on this page.

Part data for Z30-9180-001

Item Value
Part number Z30-9180-001
Item Wiring board, HART (item 2 in the E4 list)
Also listed for Pulsar Model R86, digit 5 = 1 with digit 8 = 0, 1, A or D
Fits E4 Modulevel HART transmitter head

Host instrument data: E4 Modulevel

Item Value
Measurement principle Buoyancy, continuous displacement with a precision range spring and an LVDT
Physical range Up to 300 cm (120 inches), depending on displacer length
Output 4 to 20 mA with HART version 7 (3.8 to 20.5 mA usable per NAMUR NE 43)
Supply at instrument terminals 11 to 36 VDC under certain conditions
Media Liquids or slurries, specific gravity 0.23 to 2.20
Process pressure 348 bar at +38 degrees C (5050 psig at +100 degrees F)
Process temperature Steam -29 to +260 degrees C; non-steam -29 to +445 degrees C
Electronics operating temperature -40 to +80 degrees C
Housing Die-cast aluminum A413, optional stainless steel; 1/2 inch NPT or M20 entry
Safety SIL 2 certified as 1oo1 per IEC 61508

Typical applications in oil and gas, utilities, water and manufacturing

Displacer transmitters are used where a purely mechanical sensing element is preferred on process and storage vessels, bridles, bypass chambers, interface service and sumps. The catalog lists liquids or slurries from light hydrocarbons to heavy acids, and notes the ability to track a liquid-liquid interface or a changing specific gravity when the displacer is specified for that duty.

In Oman and the GCC, instruments of this kind are found in oil and gas production and processing, petrochemical and refining units, power and desalination plants, water and wastewater works, and general manufacturing. A replacement wiring board such as Z30-9180-001 is normally ordered during a turnaround or after a fault, when the loop must return to service quickly, so having the exact number in hand saves time.

Selection and compatibility notes for Z30-9180-001

  • The R86 manual lists Z30-9180-002 and other boards for other digit 8 variants, so match the classification digit before ordering.
  • The E4 list shows the board as item 2, next to the electronic module Z31-2883-001.
  • Note the cable entry and approvals on the nameplate when you send the request.

Please treat the model code and the serial number on the nameplate as the final authority. If your instrument is older than the manual revision we reference, send the nameplate photo and we will tell you whether Z30-9180-001 is listed for it before you commit to an order.

Installation and commissioning of Z30-9180-001

Follow the installation section of manual 48-636 and its warnings. In particular, do not connect or disconnect energized equipment in a hazardous area unless power has been switched off or the area is known to be non-hazardous, and keep the housing covers and O-rings in good condition so the enclosure rating is kept.

  • The enclosing tube acts as a static isolation barrier between the LVDT and the process medium, according to the catalog.
  • The manual footnotes that field replacement of the LVDT kit requires a user calibration of the repaired unit, so plan commissioning time when it is changed.
  • Configuration uses the four-button local interface or PACTware with the DTM; no level change is needed for configuration.

Maintenance and spares planning

Spare parts for process instruments are best planned from the nameplate data of each installed unit. For this family, the manufacturer lists the parts in groups, so related items are easy to review together with Z30-9180-001. Keep a record of the model number, serial number and the digits that selected the part, and store electronic parts in antistatic packing until fitting. After any replacement, check the output against a known reference and record the result in the loop file.

Related products and ordering notes

Other numbers in the same manual section may suit sister variants, for example the alternatives listed in the table above. Ask us about the whole spares list for a unit if you are building a turnaround kit, and send the instrument model with every request so that Z30-9180-001 is checked against it. Availability and lead time depend on stock and on the source, and we give them with the quotation.

FAQ summary for Z30-9180-001

Buyers most often ask what Z30-9180-001 is, which instrument it fits, whether Seven Star LLC can supply it in Oman, whether a manual is available, and what to send with a request. The answers are given in the FAQ list on this page, and in short: Z30-9180-001 is the manufacturer number for the wiring board of the E4 Modulevel, and we need the model number, serial number, quantity and delivery location to quote.

Documents and quotation

The manufacturer manual 48-636 that lists Z30-9180-001 is attached to this page as a PDF for reference, so you can check the part drawing and the model code table yourself. To obtain a quotation, send an RFQ with the part number Z30-9180-001, the quantity, the instrument model and serial number, and the delivery location. Seven Star LLC replies with availability and lead time.

Other Models in the Magnetrol E4 Range

Seven Star LLC supplies models from the Magnetrol E4 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Magnetrol Z31-2883-001 HART Electronic Module for E4 ModulevelMagnetic, Magnetostrictive & Displacer LevelView details
Magnetrol Z31-2850-001 Display Module for E4 Modulevel, Pulsar R86Magnetic, Magnetostrictive & Displacer LevelView details
Magnetrol Z30-9180-001 HART Wiring Board for E4 Modulevel, Pulsar R86Magnetic, Magnetostrictive & Displacer LevelYou are viewing this model
Datasheets & Documents
  • PDF Manual Magnetrol Z30-9180-001 HART Wiring Board for E4 Modulevel, Pulsar R86 Manual with Parts List Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.

Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.

Magnetrol company profile

Established 1932, USA; headquarters in Aurora, Illinois
Ownership Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group
Product families Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand)
Applications Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection

Milestones

  • 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
  • 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
  • 2021: AMETEK acquires Magnetrol on 29 March.

Magnetrol products we list

Model Principle Typical use
Eclipse 706 Guided wave radar Level and interface in separators, chambers and boiler drums, unaffected by changing density
Pulsar R80 80 GHz FMCW radar Narrow-beam non-contact level in tanks with internals and in solids
Pulsar R86 26 GHz radar Non-contact level in process and storage vessels
Pulsar R96 6 GHz radar Non-contact level where vapour, foam or condensation are present
E4 Modulevel Displacer Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units
Echotel 961/962 Ultrasonic gap switch High and low level alarms and pump protection
Thermatel TD1/TD2 Thermal dispersion switch Flow and no-flow detection and level switching for liquids and gases

Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.

Where Magnetrol instruments are used

In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.

Ordering Magnetrol instruments: what we need

Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.

Facts checked against Magnetrol and AMETEK company information, October 2026.

FAQ

Questions about the Magnetrol Z30-9180-001 HART Wiring Board for E4

Answers from our engineering team on installation, compatibility and integration.

01What is Z30-9180-001?
Z30-9180-001 is the Magnetrol part number for the wiring board of the E4 Modulevel displacer level transmitter. It is listed in the replacement parts section of the manufacturer manual 48-636.
02Which instrument does Z30-9180-001 fit?
It is listed for the E4 Modulevel displacer level transmitter. The model code digits shown on this page select the exact variant, so please confirm the model and serial number with us before ordering.
03Can Seven Star LLC supply Z30-9180-001 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with Z30-9180-001, the quantity and the delivery location and we will confirm availability.
04Is a manual available for Z30-9180-001?
Yes. The manufacturer manual 48-636 that contains the parts list for Z30-9180-001 is provided as a PDF on this page, so you can check the drawing and the model code table.
05What should I send with an RFQ for Z30-9180-001?
Send the part number Z30-9180-001, the quantity, the instrument model number and serial number, the supply or approval details on the nameplate, and the delivery location so we can prepare an accurate quotation.