Brand: ALICAT
Alicat MCV-100SCCM Flow Controller with Shutoff Valve 100 SCCM
Description
The Alicat MCV-100SCCM is a mass flow controller with an integrated Swagelok positive shutoff valve and a 100 SCCM full scale. In the MCV mid-range sheet the 10 to 500 SCCM sizes share a pressure drop of 1.0 PSID and 1/4 inch VCR male process connections.
Mass flow control with a leak-tight shutoff
A normal controller valve is not designed to seal fully. The MCV-Series adds a pneumatically actuated, normally closed Swagelok shutoff valve, and the sheet states that the sourced valves have a specified leak rate below 1 x 10-9 atm-cc/s, so the line stays isolated when the controller is idle and vacuum integrity is preserved.
Measurement is by the Alicat laminar element, with accuracy of 0.6 % of reading or 0.1 % of full scale, whichever is greater, and 0.5 % or 0.1 % with the high-accuracy option. The controller has a 0.01 to 100 % control range and a response as fast as 30 ms.
Key features as printed in the datasheet
- Swagelok pneumatically actuated shutoff valve; more than 60 PSIG air source needed.
- External leak integrity better than 1 x 10-9 atm-cc/s on all devices.
- Accuracy 0.6 % of reading or 0.1 % of full scale; 0.5 % / 0.1 % high accuracy.
- 98 gases with Gas Select and 20 user mixes with COMPOSER.
- Operating pressure up to 160 PSIA full scale.
Technical specification
Performance data (MCV sheet)
| Parameter | Specification |
|---|---|
| Full scale | 100 SCCM |
| Mass flow accuracy | 0.6 % of reading or 0.1 % of full scale, whichever is greater; high accuracy 0.5 % / 0.1 % |
| Repeatability (2 sigma) | 0.1 % of reading + 0.02 % of full scale |
| Steady-state control range | 0.01 to 100 % of full scale |
| Operating pressure | full scale 160 PSIA; minimum 11.5 PSIA common mode |
| Pressure accuracy | above 1 atm 0.5 % of reading; below 1 atm 0.07 PSIA |
| Operating temperature | -10 to 60 degC; accuracy 0.75 degC |
| Control response | as fast as 30 ms, adjustable |
| Sensor / indication response | under 1 ms / under 10 ms |
Mechanical and feature data
| Parameter | Specification |
|---|---|
| Pressure drop at full scale | 1.0 PSID |
| Process connection | 1/4 inch VCR male |
| Dimensions / weight | 4.755 x 6.722 x 1.500 in (120.8 x 170.7 x 38.1 mm) / approx. 3.0 lb (1.4 kg) |
| Wetted materials | 302, 303, 304, 316L and 430FR stainless steel; FKM, alumina ceramic, brass, glass, gold, epoxy, silicone rubber, polyamide, silicon |
| Maximum pressure | 175 PSIA common mode; 75 PSI differential rapid change |
| Shutoff valve | Swagelok, pneumatic, normally closed, leak rate under 1 x 10-9 atm-cc/s |
| Ingress protection / humidity | IP40 / 0 to 95 % non-condensing |
| Mounting | 4 pass-through holes, 0.240 in diameter |
| Display | monochrome LCD or colour TFT with touchpad; flow, temperature, setpoint, pressure |
Selection and ordering guide
The MCV sheet covers 10 SCCM to 20 SLPM; sizes of 1 SLPM and above have higher pressure drops (1.5 to 20 PSID). A separate MCV low-range sheet covers 0.5 to 5 SCCM. This sheet is revision 0 dated July 2020, so ask for current options before ordering.
Specify the gas, the supply and the shutoff actuation pressure, because the Swagelok valve needs a pneumatic source above 60 PSIG.
Note the sheet revision before you rely on every figure: the MCV sheet is revision 0 from 14 July 2020, and Alicat has since revised other controller sheets, so quote requests should ask for the current specification and the current shutoff valve model. A controller of this type is normally integrated into a gas panel with VCR fittings, a purge line and a leak check procedure, and the pneumatic actuation line should be given its own regulator and a filter. Keep the shutoff and the controller electrically and pneumatically coordinated, so the shutoff opens before a flow setpoint is applied and closes after it is removed.
Installation and operation notes
Install the controller with VCR gaskets and a leak check at the connections, supply the shutoff valve with clean, dry air at more than 60 PSIG and use a suggested in-line filter of about 20 microns upstream of the flow device where permitted. Tare with no flow before use.
Do not exceed the 175 PSIA common-mode limit or 75 PSI differential, and vent the pneumatic supply safely.
Applications in Oman and the GCC
Controlled shutoff gas feeds suit semiconductor and thin-film process research, vacuum chambers, mass-spectrometer and analytical gas supplies, and chemical-vapour deposition test stands, wherever a tight seal between runs is needed. Confirm wetted-material compatibility.
Compatible accessories and related items
Related items on this site include the MC-100SLPM controller for larger flows and the BM-100SCCM compact meter.
Related ALICAT products: Alicat MC-100SLPM Mass Flow Controller 100 SLPM, Alicat L-100CCM Liquid Flow Meter 100 CCM, Alicat BM-100SCCM BASIS 2.0 Mass Flow Meter 100 SCCM, Alicat M-2000SLPM Gas Mass Flow Meter 2000 SLPM, Alicat ISMC-NB IS-Max Intrinsically Safe Flow Controller and Alicat MW-500SLPM WHISPER Low Pressure Drop Mass Flow Meter.
Alicat MCV-100SCCM selection checklist
Before ordering an Alicat MCV-100SCCM, confirm that the full-scale range of 100 standard cubic centimetres per minute covers both the normal and the peak flow of the process. A controller sized too large spends most of its life near the bottom of its range, where the relative error is highest, while one sized too small cannot reach the set point during purges or start-up. If the expected flow sits between roughly 5% and 90% of full scale, this range is usually a good fit.
Next, list the gas or gas mixture, the inlet and outlet pressures and the process temperature. These values decide the valve orifice, the seal material and whether the integrated shutoff valve can hold tight against the available differential pressure. Corrosive or reactive gases may need different elastomers than air or nitrogen, so state the gas clearly on the request.
Finally, decide how the Alicat MCV-100SCCM will talk to the control system: analog set point and feedback, RS-232 or RS-485 serial, or an industrial fieldbus option. Note the required electrical connector, the process fittings and any calibration certificate the site needs. With this information Seven Star LLC can quote the correct configuration the first time and avoid delays at commissioning.
Documents and quotation
For quotation, send your required quantity and destination. The ALICAT datasheet for MCV-100SCCM is provided below the description on this page. Seven Star LLC works as an independent supplier from Muscat. Please compare code, ratings and approvals with the document before you place an order; see also the category listing.
Datasheets & Documents
- Datasheet Alicat MCV-Series mass flow controller spec sheet DOC-SPECS-MCV-MID, rev 0 July 2020 (PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Alicat Scientific is an American manufacturer of mass flow meters, mass flow controllers and pressure controllers for gases and liquids, founded in 1991 in Tucson, Arizona, where it is still based. Its instruments use differential pressure across a laminar flow element to measure flow. Alicat has been part of Halma plc since November 2010.
ALICAT company profile
| Founded | 1991, Tucson, Arizona |
|---|---|
| Headquarters | Tucson, Arizona |
| Ownership | Halma plc, since November 2010 |
| Measuring principle | Laminar differential pressure |
| Product families | M and MC gas mass flow meters and controllers, BASIS 2.0 OEM meters, WHISPER low pressure drop meters, L liquid flow meters, IS-Max intrinsically safe controllers, pressure controllers |
Milestones
- 1991: Alicat is founded in Tucson.
- 2010: Halma acquires Alicat.
Mass flow, liquid flow and pressure instruments
The ALICAT range covers gas mass flow meters and controllers, liquid flow meters, pressure meters and pressure controllers, with intrinsically safe IS-Max versions and compact BASIS models for OEM use. Most instruments store 98 gases, show flow, pressure and temperature on an interactive display and offer Modbus RTU and industrial fieldbus options.
Typical industries
ALICAT lists calibration and metrology, gas chromatography, semiconductor thin film deposition, leak testing, hydrogen, bioreactors and oil and gas research laboratories among its industries. Seven Star LLC quotes ALICAT instruments in Oman and the GCC with the official specification sheet for each item.
ALICAT products we list
Facts checked against Alicat's own about page and Halma's 2010 announcement, October 2026.
FAQ
Questions about the Alicat MCV-100SCCM Flow Controller with Shutoff
Answers from our engineering team on installation, compatibility and integration.
01What is the MCV-100SCCM?
A 100 SCCM mass flow controller with an integrated Swagelok pneumatic shutoff valve.
02What is the leak integrity?
External leak rates better than 1 x 10-9 atm-cc/s, and shutoff valves specified below that rate.
03What process connection is used?
1/4 inch VCR male.
04What air supply does the shutoff need?
A pneumatic source above 60 PSIG.
05Does Seven Star LLC act as an ALICAT distributor?
No. Seven Star LLC is an independent supplier in Muscat that sources ALICAT products on request.