Extech MA443 400 A True RMS AC Clamp Meter with NCV and Type K
Description
Extech MA443 400 A true RMS AC clamp meter with NCV and Type K
The Extech MA443 is a 400 A true RMS AC clamp meter with a 30 mm (1.2 in) jaw for conductors up to 500 MCM, a non-contact voltage detector, a built-in flashlight and a Type K thermocouple input. It is the middle model of the MA440 series, which also includes the MA440 (AC, non-true-RMS) and the MA445 (true RMS AC/DC); the MA443 counts ten functions.
The multimeter functions include AC/DC voltage, resistance, capacitance and frequency, with a large backlit display, relative mode, data hold, Max/Min and an auto power off that can be disabled. The kit contains test leads, three AAA batteries, a pouch and a general-purpose Type K probe.
Technical specifications of the MA443
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Extech / MA443 (MA443-NIST available with calibration traceable to NIST) |
| AC current | 400.0 A true RMS, ±1.8% |
| AC voltage | 600 V, 1 mV resolution |
| DC voltage | 600 V true RMS, 0.1 mV resolution |
| Voltage accuracy | AC ±1.2%, DC ±0.8% |
| Non-contact voltage | 100 to 600 V |
| Resistance | 40 MΩ, 0.1 Ω resolution |
| Capacitance | 40 mF, 0.01 nF resolution |
| Frequency | 1 MHz, 0.01 Hz resolution |
| Temperature (Type K) | -40 to 1000 °C (-40 to 1832 °F) meter range; the supplied general-purpose probe does not cover the full range |
| Functions | Relative mode, data hold, Max/Min, flashlight, auto power off with disable, low battery indication |
| Jaw | 30 mm (1.2 in), conductors up to 500 MCM |
| Power | 3 x AAA |
The figures above are from the MA440 series datasheet.
How the MA443 differs from other MA440 series models
| Model | Current functions | Notes |
|---|---|---|
| MA440 | AC current, 9 functions | Not true RMS, no Type K, capacitance 100 µF |
| MA443 | True RMS AC current, 10 functions | Type K temperature, flashlight, Max/Min |
| MA445 | True RMS AC/DC current, 11 functions | Adds DC current and DC zero |
Choose the MA443 when the loads include variable speed drives or electronic power supplies, because true RMS reads the distorted waveform correctly. If DC current is needed for batteries or automotive circuits, choose the MA445; if only basic AC current is needed, the MA440 is the economical choice.
Using the MA443 on motors and HVAC equipment
- Clamp one phase conductor at a time to read motor running current and compare with the nameplate.
- Use the capacitance range to check run and start capacitors on single-phase motors.
- Use the Type K input to record bearing, winding case or refrigerant line temperature while watching current.
- Use the NCV to find the live conductor before opening panels.
- Use Max/Min to see the swing in current during a cycle.
For 1500 A feeders or DC current, use the Extech MA1500; for a pocket 60 A clamp, use the MA63.
Selection checklist for the MA443
- Confirm maximum AC current is below 400 A and conductors fit a 30 mm jaw.
- Decide whether true RMS and Type K temperature are needed (MA443) or DC current (MA445).
- Check capacitor sizes: the MA443 range reaches 40 mF.
- Check availability of spare AAA batteries.
- Decide whether the -NIST calibration version is required.
Care of the MA443
Keep the jaw faces clean and fully closed, avoid dropping the meter, and clamp one conductor only. Remove the test leads from the meter when measuring current, since the leads and the jaw are separate inputs. The NCV indicates the presence of voltage but is not a replacement for a proper dead test. The general-purpose Type K probe does not cover the full range of the meter, so use a suitable probe for high temperatures.
Applications of the MA443 in Oman and the GCC
Electricians and maintenance teams at industrial plants and commercial buildings use a 400 A true RMS clamp for routine current checks on motors, pumps, fans and air-conditioning equipment, where the load is often drive-fed. Hot ambient conditions raise winding temperatures, so the Type K temperature function is useful to correlate current and temperature on bearings and terminals during site rounds.
Measurement technique with the MA443
Current readings depend on technique as much as on the instrument. Open the jaw, enclose a single conductor, centre it between the marks and close the jaw fully; a conductor held against the edge of the jaw can change the reading slightly. Keep other current-carrying conductors away from the jaw, since their fields add to the measurement. When checking a three-phase motor, measure all three phases and compare the highest and lowest values; an imbalance of more than a few percent suggests a supply, winding or connection problem that deserves investigation.
When measuring temperature with the Type K input, allow the probe to settle for a few seconds, attach it firmly to a clean surface, and use the relative mode to compare two points, for example the temperature of adjacent terminals on the same feeder. Log the current and the temperature together with the time, since a hot terminal under load is a stronger warning than a hot terminal at no load.
Information to send with an RFQ for the MA443
- Part number MA443 and the required quantity
- Maximum current and conductor size
- Whether a different MA440 series model (MA440 or MA445) is required
- Delivery location in Oman or the GCC and the required lead time
- Whether calibration documentation or a traceable calibration certificate is required
Documents and quotation
A datasheet for the Extech MA443 is attached on this page. It covers the MA440, MA443 and MA445 models.
Send us the part number MA443, the quantity and the delivery location in Oman or the GCC, and we will reply with availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Other Models in the Extech Clamp Meters Range
Seven Star LLC supplies models from the Extech Clamp Meters range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Extech 380950 80 A Mini AC/DC Clamp Meter, 1 mA Resolution | Electrical Testers & Multimeters | View details |
| Extech 380976-K 1000 A AC Power Clamp Meter Kit, 1 and 3 Phase | Electrical Testers & Multimeters | View details |
| Extech MA1500 1500 A True RMS AC/DC Clamp Meter with NCV | Electrical Testers & Multimeters | View details |
| Extech MA63 60 A True RMS AC/DC Clamp Meter with NCV | Electrical Testers & Multimeters | View details |
| Extech MA443 400 A True RMS AC Clamp Meter with NCV and Type K | Electrical Testers & Multimeters | You are viewing this model |
Datasheets & Documents
- Datasheet Extech MA443 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Extech Instruments is an American brand of handheld test and measurement instruments, founded in the early 1970s in Waltham, Massachusetts. FLIR Systems acquired Extech in 2007 for about $40 million, and FLIR itself became part of Teledyne in 2021. Extech is based in Nashua, New Hampshire, and makes meters for electrical, environmental and HVAC testing.
Extech company profile
| Founded | Early 1970s, Waltham, Massachusetts |
|---|---|
| Headquarters | Nashua, New Hampshire (since 2011) |
| Ownership | Teledyne FLIR |
| Acquired by FLIR | 2007 |
| Product families | True RMS clamp meters and multimeters, insulation testers, power analysers, IR thermometers, light meters, vibration meters, sound, humidity and air quality meters |
Milestones
- 2007: FLIR Systems acquires Extech.
- 2011: Extech moves to Nashua.
- 2021: FLIR becomes part of Teledyne.
Meters, testers and inspection tools
The Extech range includes multimeters and clamp meters, insulation and resistance testers, power analyzers, thermometers, light and sound level meters, anemometers, tachometers, vibration meters, moisture meters, borescopes and water quality meters. Each datasheet and user manual lists ranges, accuracy, safety category and ordering codes, and many models are listed with NIST-traceable calibration versions ordered by adding -NIST to the part number.
Supply through Seven Star LLC
Seven Star LLC is an independent supplier in Muscat that quotes Extech products for projects in Oman and the GCC, with the official Extech datasheet and user manual attached to each product page.
Extech products we list
Facts checked against FLIR's 2007 announcement and published Extech histories, October 2026.
FAQ
Questions about the Extech MA443 400 A True RMS AC Clamp Meter with NCV
Answers from our engineering team on installation, compatibility and integration.
01What are the main features of the Extech MA443?
The MA443 is a true RMS 400 A AC clamp meter with NCV, Type K temperature, flashlight, Max/Min and multimeter functions in a 30 mm jaw.
02What is the jaw size of the MA443?
The jaw is 1.2 in (30 mm) and fits conductors up to 500 MCM.
03Does the MA443 measure DC current?
No. The MA443 measures AC current only; the MA445 in the same series adds DC current.
04What temperature range can the MA443 measure?
The meter range is -40 to 1832 °F (-40 to 1000 °C) with a Type K probe, but the general-purpose probe supplied does not cover the whole range.
05What batteries does the MA443 use?
The MA443 uses three AAA batteries, supplied together with test leads, a pouch and a Type K probe.