Brand:

Bürkert 560205 Type 8619 multiCELL Flow Transmitter Controller

Description

Overview

Bürkert 560205 is the base multiCELL, the panel-mounted Type 8619 multi-channel transmitter and controller with flow measurement. Without any analytical module it still brings two digital inputs for flow pulses or frequency signals, two transistor outputs and two 4 to 20 mA analogue outputs. It sits in a quarter DIN housing and is operated from 12 to 36 V DC, which makes it a convenient indicator, totaliser and dosing controller for flow lines. Seven Star LLC is an independent supplier serving Oman and the GCC.

What is inside Bürkert 560205

  • Main module with display, keypad, data logger and real-time clock.
  • Two digital inputs (0.5 to 2500 Hz) for flow sensors such as paddle wheel or Hall devices.
  • Two transistor outputs, any connection in PNP or NPN mode.
  • Two galvanically isolated 4 to 20 mA outputs.
  • No pH, conductivity or Ethernet module, and no UL approval for this specific article number.

Technical data for Bürkert 560205

Parameter Value
Article 560205, base unit with flow measurement
Digital inputs 2, 0 to 36 V DC, Von 5 to 36 V, Voff below 2 V, 3 kOhm
Transistor outputs 2, max. 2000 Hz, 700 mA with one output per module
Analogue outputs 2 x 4 to 20 mA, 6 microamp resolution
Sensor raw signals none
UL approval No
Housing Panel-mounted multiCELL, 1/4 DIN, 92 x 92 mm cutout, PPO housing
Supply 12 to 36 V DC plus or minus 10 percent, max. 2 A, via external SELV and LPS supply
Power consumption max. 1.5 VA for the main module alone
Display LC graphic display, 128 x 168 pixels, light blue backlight, English, German, French
Keys 4 soft keys and 1 central navigation key
Module slots 6
Data logger up to 16 values, SD or SDHC card up to 8 GB
Ambient temperature minus 10 to plus 70 degrees C with main module only; up to plus 60 degrees C with an additional module
Protection IP65 or NEMA 250 4X in front of a closed cabinet; IP20 behind the panel
Altitude and humidity max. 2000 m, below 85 percent without condensation

Where Bürkert 560205 fits in the multiCELL order chart

The ordering chart is built around the main module and its optional modules. 560205 is the entry point without extras. Article 560200 adds one pH and ORP module with a Pt100 or Pt1000 input, 560201 adds a conductivity module, 560204 combines both with an extra output module, and 569259 keeps the flow-only layout but adds an Ethernet module for Modbus TCP. If your project only needs to read flow and drive two outputs, the base unit saves money and wiring.

Applications for flow monitoring and batching

In water treatment, cooling water and chemical dosing skids, the base multiCELL turns pulses from a Bürkert paddle wheel or Hall flow sensor into flow rate and total volume, then drives a dosing pump or valve through its outputs. Typical uses in Oman and the Gulf include filtration backwash monitoring, chemical injection ratio control, bottling and filling lines, and cooling tower make-up water measurement.

Panel mounting of the multiCELL

The panel-mounted multiCELL fits a standard 92 x 92 mm cut-out in a cabinet door and is held by four fastening elements. Front protection to IP65 and NEMA 250 4X applies only when the cabinet door is closed and the unit is correctly sealed, while the rear of the housing is IP20 and must be protected inside the enclosure. Plan terminal access from behind, allow room for RJ45 cables and for the SD card slot, and keep power cables away from low-level signal wires. Shielded cable should be earthed at one end according to the data sheet wiring notes.

Outputs and control functions

Transistor outputs can be wired in PNP or NPN mode, are short-circuit protected, switch up to 36 V DC and can run at up to 2000 Hz. Operating modes include on and off, hysteresis, window, PWM and PFM, so the same hardware can dose a pump, drive a proportional valve or switch an alarm lamp. The 4 to 20 mA outputs have a resolution of 6 microamps and an uncertainty of plus or minus 0.5 percent of the transmitted value, with a maximum loop impedance of 610 ohms at 24 V DC.

Power supply, wiring and EMC practice

The multiCELL expects a filtered and regulated 12 to 36 V DC supply from an external limited power source. Use cable rated for more than 90 degrees C, with cross sections of 0.2 to 1.5 mm2 on the terminal strip and 0.75 to 1.5 mm2 for the earth conductor. Strip insulation to 7 mm, use ferrules where possible, and keep shielded signal cable away from motor and drive cables. Where the unit is installed outdoors or in a humid place, the maximum voltage allowed drops by one volt according to the data sheet notes for the wall variant, so confirm the supply setting before energising.

Power distribution terminals marked PWR OUT can feed external loads up to 1.8 A at the supply voltage with polarity protection, which saves a separate supply for small sensors.

Spare strategy and lifecycle

Because the factory configuration cannot be changed in the field, one device is not a perfect spare for another. Make a table of installed multiCELL articles by tag number, note the module list from the nameplate, and keep one spare for each distinct article that controls a critical process. Pair spares with a backup of the parameter set exported to the SD card so that a replacement can be commissioned in minutes.

Installation and commissioning

Mount in the cut-out, connect the SELV supply to the marked terminals, wire flow sensor to a digital input, and configure the input type and K factor from the soft key menus. Check the displayed flow against a known reference and confirm that outputs react as expected. Insert a memory card only if logging is needed and the temperature range allows.

Related items you may also need: Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Bürkert Type 8681 Control Head for Hygienic Process Valves | Advantech ADAM-4150 Robust 15-Channel Digital I/O Module with Modbus | All Bürkert products.

Documents and quotation

The Type 8619 data sheet covering Bürkert 560205 is attached and includes the ordering chart, module data, wiring and dimensions. Please send an RFQ with part number 560205, the quantity and your delivery location in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet Bürkert 560205 Type 8619 multiCELL Flow Transmitter Controller Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.

Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.

Bürkert company profile

Founded 1946, by Christian Bürkert
Headquarters Ingelfingen, Germany
Ownership Family-owned
Product families Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers

Bürkert types listed on this page

Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.

Ordering Bürkert valves: what we need

The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.

Facts checked against Bürkert's published company history, October 2026.

FAQ

Questions about the Bürkert 560205 Type 8619 multiCELL Flow Transmitter

Answers from our engineering team on installation, compatibility and integration.

01What does Bürkert 560205 measure?
It is the base multiCELL with flow measurement: two digital inputs for frequency or pulse flow sensors, plus outputs for control and signalling.
02How many outputs does 560205 have?
It has two transistor outputs and two 4 to 20 mA analogue outputs, all galvanically isolated.
03What supply does Bürkert 560205 need?
The panel-mounted device runs on 12 to 36 V DC plus or minus 10 percent from an external SELV supply with maximum 2 A.
04Does 560205 include pH or conductivity inputs?
No. This article has no analytical module; pH and conductivity versions have separate article numbers in the same ordering chart.
05Can 560205 log data?
Yes, it has a real-time clock and an SD or SDHC card slot for up to 8 GB, logging up to 16 values.