- Automation & ControlView all 3,053 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Bürkert
Bürkert 560200 Type 8619 multiCELL pH/ORP Controller
Description
Overview
Water chemistry control often needs pH and flow on one screen, and Bürkert 560200 delivers that in a single quarter DIN panel unit. It is the Type 8619 multiCELL with the main module and one pH and ORP input module, giving two digital inputs, one pH/ORP raw signal input, one Pt100 or Pt1000 temperature input, two transistor outputs and two 4 to 20 mA outputs. Seven Star LLC is an independent supplier serving Oman and the GCC.
pH measuring performance of Bürkert 560200
The pH and ORP module measures with electrochemical probes. The pH range covers minus 2.0 to plus 16 pH, equal to minus 600 to plus 600 mV, with a measurement deviation of plus or minus 0.02 pH plus the error of the probe, and a resolution of 0.01 pH. ORP is measured from minus 2000 to plus 2000 mV with plus or minus 1 mV plus probe error and 0.1 mV resolution. The Pt100 or Pt1000 temperature input works in two or three wire mode from minus 25 to plus 130 degrees C with plus or minus 1 degree C accuracy.
Data table for Bürkert 560200
| Parameter | Value |
|---|---|
| Article | 560200, main module plus 1 pH/ORP module |
| Digital inputs | 2 (flow pulses or frequency) |
| pH range | minus 2.0 to plus 16 pH, 0.01 pH resolution |
| ORP range | minus 2000 to plus 2000 mV |
| Temperature input | Pt100/Pt1000, minus 25 to plus 130 degrees C |
| Transistor outputs | 2 |
| Analogue outputs | 2 x 4 to 20 mA |
| Module power | 0.1 VA for the pH module |
| UL approval | No (UL version is 560208) |
| Housing | Panel-mounted multiCELL, 1/4 DIN, 92 x 92 mm cutout, PPO housing |
| Supply | 12 to 36 V DC plus or minus 10 percent, max. 2 A, via external SELV and LPS supply |
| Power consumption | max. 1.5 VA for the main module alone |
| Display | LC graphic display, 128 x 168 pixels, light blue backlight, English, German, French |
| Keys | 4 soft keys and 1 central navigation key |
| Module slots | 6 |
| Data logger | up to 16 values, SD or SDHC card up to 8 GB |
| Ambient temperature | minus 10 to plus 70 degrees C with main module only; up to plus 60 degrees C with an additional module |
| Protection | IP65 or NEMA 250 4X in front of a closed cabinet; IP20 behind the panel |
| Altitude and humidity | max. 2000 m, below 85 percent without condensation |
Differences between Bürkert 560200 and neighbouring articles
Against 560205 it adds the pH and ORP input with temperature compensation. Against 560201 it uses a pH module rather than a conductivity module, and the temperature range is minus 25 to plus 130 degrees C instead of minus 40 to plus 200 degrees C. Against 560202 it has one pH channel rather than two, and two outputs of each type rather than four. A UL Listed twin of this layout exists as article 560208.
Process uses
Typical duties are neutralisation tanks, boiler feed and cooling water pH control, swimming pool and water treatment dosing, effluent monitoring before discharge, and CIP circuits in food and beverage. Using the transistor outputs in PWM or PFM mode drives a dosing pump proportionally to the pH error, while the 4 to 20 mA outputs retransmit pH or temperature to a plant PLC.
Data logging and diagnostics
A real-time clock and an SD or SDHC memory card up to 8 GB give the multiCELL a data logger for up to 16 values. With eight values recorded every ten seconds, an 8 GB card runs for more than 500 days of continuous recording. The data sheet recommends the tested Bürkert card because other cards may not run reliably, and notes that with a card inserted the storage range narrows to minus 10 to plus 70 degrees C. The sensor monitor shows raw measured values directly, which helps commissioning engineers check wiring and verify probes before the control loop is closed.
Why module-based design helps spares planning
The multiCELL is configured at the factory with up to five module types in six slots: an input module, an output module, a pH and ORP module, a conductivity module and an Ethernet module. That means an article number really describes a combination, and a spare device cannot simply be re-configured in the field. For critical plants, hold a spare of the exact article rather than a nearby one, and record the module configuration printed on the nameplate in the plant asset register.
Panel mounting of the multiCELL
The panel-mounted multiCELL fits a standard 92 x 92 mm cut-out in a cabinet door and is held by four fastening elements. Front protection to IP65 and NEMA 250 4X applies only when the cabinet door is closed and the unit is correctly sealed, while the rear of the housing is IP20 and must be protected inside the enclosure. Plan terminal access from behind, allow room for RJ45 cables and for the SD card slot, and keep power cables away from low-level signal wires. Shielded cable should be earthed at one end according to the data sheet wiring notes.
Standards and approvals worth checking
The multiCELL carries CE conformity and is available in UL Listed and UL Recognized versions for the USA and Canada, selected by a separate article number in each row of the ordering chart. If your project specification demands UL, pick the matching UL article rather than assuming the non-UL one is covered. The device is designed for continuous operation, fixed installation, pollution degree 2 and installation category I, and is intended for indoor and outdoor use within the stated temperature and humidity limits.
Commissioning and calibration
Connect the electrochemical probe with suitable cable, enter buffer values at the calibration menu, and check the slope and offset reported by the device. Review the temperature compensation, assign the output to a dosing pump and enter the setpoint with a dead band to avoid over-dosing. Clean probes monthly in dirty water and replace them as soon as the slope falls out of limits.
Related items you may also need: Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Bürkert Type 8681 Control Head for Hygienic Process Valves | Endress+Hauser CM448R Liquiline Eight-Channel DIN-Rail Transmitter | All Bürkert products.
Documents and quotation
The Type 8619 data sheet containing Bürkert 560200 is attached with ordering chart, wiring and module information. Send your RFQ with part number 560200, quantity and delivery location in Oman or the GCC.
Other Models in the 8619 Range
Seven Star LLC supplies models from the 8619 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Bürkert 560205 Type 8619 multiCELL Flow Transmitter Controller | Controllers & Data Acquisition | View details |
| Bürkert 560200 Type 8619 multiCELL pH/ORP Controller | Controllers & Data Acquisition | You are viewing this model |
Datasheets & Documents
- Datasheet Bürkert 560200 Type 8619 multiCELL pH/ORP Controller Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.
Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.
Bürkert company profile
| Founded | 1946, by Christian Bürkert |
|---|---|
| Headquarters | Ingelfingen, Germany |
| Ownership | Family-owned |
| Product families | Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers |
Bürkert types listed on this page
Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.
Ordering Bürkert valves: what we need
The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.
Facts checked against Bürkert's published company history, October 2026.
Browse Bürkert products by category: Solenoid Valve, Control Valves.
FAQ
Questions about the Bürkert 560200 Type 8619 multiCELL pH/ORP Controller
Answers from our engineering team on installation, compatibility and integration.
01What does Bürkert 560200 measure?
It is a multiCELL with one pH and ORP input module plus a Pt100 or Pt1000 input, together with flow inputs and control outputs.
02What pH range does 560200 support?
The pH module covers minus 2.0 to plus 16 pH with a resolution of 0.01 pH, and ORP from minus 2000 to plus 2000 mV.
03Does Bürkert 560200 have UL approval?
This article does not; the UL version of the same configuration is listed in the ordering chart as article 560208.
04How many analogue outputs does 560200 have?
It has two 4 to 20 mA outputs, plus two transistor outputs that can run in on-off, hysteresis, window, PWM or PFM modes.
05What supply does 560200 require?
It runs from 12 to 36 V DC via an external SELV power supply with a maximum of 2 A.


















Reviews
There are no reviews yet.