Brand:

Bürkert 419587 Type 8020 Insertion Paddle Wheel Flow Sensor

Description

Overview

Bürkert 419587 is the Hall-effect, short-stem version of the Bürkert Type 8020, an insertion paddle wheel flow sensor for pipes from DN 20 up to DN 400. It has no display of its own: the sensor delivers a frequency signal with pulse outputs that is read by a transmitter, a batch controller or directly by a PLC. The wetted parts are PVDF with a ceramic axis and bearing and an FKM seal, a combination that handles water and many mild chemicals. Seven Star LLC is an independent supplier serving Oman and the GCC.

What the signal looks like

The Hall variant needs 12 to 36 V DC and consumes up to 50 mA. It has two open-collector transistor outputs, one NPN and one PNP, each able to carry up to 100 mA, and the pulse frequency ranges from 0 to 300 Hz with a duty cycle of one half plus or minus 10 percent. The NPN output switches between 0.2 and 36 V DC, while the PNP output follows the supply voltage. Because the output is a simple pulse train, the pulses per litre depend on the K factor of the fitting that holds the sensor, and the device can be taught on the actual flow for better accuracy.

Technical data of Bürkert 419587

Property Value
Article number 419587
Type 8020 insertion paddle wheel flow sensor, Hall variant, short sensor
Pipe size DN 20 to DN 400, with Insertion fitting Type S020
Flow range 0.5 to 75000 l/min
Flow velocity 0.3 to 10 m/s
Deviation plus or minus 1 percent after teach-in; plus or minus 2.5 percent with standard K factor
Linearity / repeatability plus or minus 0.5 percent of full scale / plus or minus 0.4 percent of reading
Supply voltage 12 to 36 V DC, filtered and regulated; reverse polarity and overvoltage protected
Current consumption up to 50 mA
Output pulse frequency, NPN and PNP transistors, open collector, 0 to 300 Hz
Wetted materials PVDF armature and paddle wheel, ceramic axis and bearing, FKM seal
Housing PE; union nut PC; screws stainless steel
Fluid pressure up to PN 10
Viscosity / solids up to 300 cSt; up to 1 percent solids, particles up to 0.5 mm
Process connection G2 for Insertion fitting Type S020
Electrical connection female cable plug to DIN EN 175301-803
Ambient temperature minus 15 to plus 60 degrees C
Degree of protection IP65 when wired with the cable plug tightened

How 419587 differs from other Type 8020 variants

Type 8020 is sold in four main codes. Article 419587 is the Hall variant with the short sensor; 419589 is the same electronics with a long sensor for fittings that need the longer reach, such as saddles or screw-on spigots. The Low Power pair, 419591 and 419593, has a single NPN transistor output at up to 10 mA and takes below 0.8 mA from the connected transmitter, so it is only suitable with the Low Power transmitters. The Hall variant here is the code for PLCs and for the universal transmitters that supply 12 to 36 V.

Where it fits on a plant

Large water lines are the natural habitat: cooling-water headers, desalination feed and reject lines, fire-water monitoring, irrigation mains and district cooling loops. The insertion principle is economical on big pipes, because a single sensor in a fitting replaces an expensive in-line meter. In Gulf industrial sites it frequently serves for chemical dosing proportional control and for flow totalising of utility water, together with a PLC counter input or batch controller.

Selection notes

The short sensor fits T-fittings and some welding sockets, while other fittings need the long version, so check the fitting data sheet for Type S020 before ordering. The fitting material also sets the fluid temperature range: PVC from 0 to 50 degrees C, PP from 0 to 80, and PVDF, stainless steel or brass from minus 15 to plus 80. The measured liquid should be free of fibres, and the sensor requires straight inlet and outlet runs. The seal can be EPDM instead of FKM as an option, and the cable plug is ordered separately.

Accuracy and what affects it

The data sheet quotes the accuracy under reference conditions, with water and both ambient and water temperature at 20 degrees C. With the standard K factor of the fitting the deviation is plus or minus 2.5 percent of the measured value; after a teach-in at a known flow the deviation shrinks to plus or minus 1 percent at that flow value. Real plants rarely match the reference condition, so allow for the straight pipe lengths before and after the sensor, avoid air pockets and keep the flow velocity inside the 0.3 to 10 m/s window. Below the lower velocity limit the paddle wheel simply does not turn smoothly, and above the upper limit wear increases.

Installation and set-up

Install the sensor in the fitting with the union nut, align the flow arrow, and make sure the pipe is full at the measuring point. Connect the supply and signal wires with the shielded cable up to 50 m in length. If the device is mounted in a humid area or outdoors, the data sheet limits the supply to 35 V DC. Perform a teach-in with a known flow when the best accuracy is needed.

Care of the paddle wheel

The ceramic axis resists wear, but fouling on the paddle wheel will reduce the signal. Check at service intervals for deposits and clean with a soft brush and a mild solvent compatible with PVDF. Replace the seal when the sensor is removed from a pressurised line.

Ordering Bürkert 419587

Please give your fitting type, pipe diameter, medium and temperature along with the quantity so we can confirm that the short sensor suits your fitting. We can quote the cable plug, the seal set and the Type S020 fitting as well.

When requesting a quotation for Bürkert 419587, quote the full Bürkert 419587 designation from the nameplate or order code so the correct variant is matched, and mention the plant tag if the unit replaces an installed device.

Related items you may also need: Bürkert 221602 Type 6213 Servo-Assisted 2/2-Way Solenoid Valve | Bürkert 178275 Type 6027 Stainless 2/2-Way Plunger Valve | Bürkert Type 8681 Control Head for Hygienic Process Valves | All Bürkert products.

Documents and quotation

The manufacturer data sheet for Type 8020 is attached, including the dimensions, pressure-temperature diagram and ordering chart. Please send an RFQ with the part number Bürkert 419587, the quantity and your delivery location in Oman or the GCC, and we will return availability and lead time.

Datasheets & Documents
  • PDF Datasheet Bürkert 419587 Type 8020 Insertion Paddle Wheel Flow Sensor Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.

Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.

Bürkert company profile

Founded 1946, by Christian Bürkert
Headquarters Ingelfingen, Germany
Ownership Family-owned
Product families Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers

Bürkert types listed on this page

Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.

Ordering Bürkert valves: what we need

The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.

Facts checked against Bürkert's published company history, October 2026.

FAQ

Questions about the Bürkert 419587 Type 8020 Insertion Paddle Wheel

Answers from our engineering team on installation, compatibility and integration.

01What is Bürkert 419587?
Bürkert 419587 is a Type 8020 Hall-effect insertion paddle wheel flow sensor, short sensor version, for pipes DN 20 to DN 400 using an S020 fitting.
02What signal does 419587 give?
The 419587 sensor gives a pulse frequency of 0 to 300 Hz on NPN and PNP open-collector outputs, powered from 12 to 36 V DC at up to 50 mA.
03Does Bürkert 419587 have a display?
No. Type 8020 has no display; connect it to a transmitter such as Type 8025, a batch controller or a PLC counter input.
04What is the difference between 419587 and 419589?
Both are Hall variants with the same electronics; 419587 has the short sensor and 419589 the long sensor, which suits other fitting types.
05What liquids can Bürkert 419587 measure?
It suits clean water and compatible liquids up to 300 cSt with up to 1 percent solids; check PVDF and FKM resistance and the fitting material.