- Automation & ControlView all 3,140 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Pizzato
Pizzato CS MP202M0 Programmable Safety Module, 16 Inputs
Description
Overview
A packaging line or a robot cell can easily carry sixteen safety devices: door switches, light curtains, e-stops at every operator station and a few enabling switches. The Pizzato CS MP202M0 is the Gemnis module that suits such a count. It offers 16 safety inputs in a housing only 45 mm wide, 4 test outputs, 4 PNP safety outputs and 4 signalling outputs, and it is programmed through a USB port. With a system response time below 30 ms and limits of Maximum SIL 3, PL e and category 4, it replaces a rack of single-function relays by one program. Seven Star LLC is an independent supplier serving Oman and the GCC.
Numbers that define the Pizzato CS MP202M0
| Item | Value from the catalogue |
|---|---|
| Safety inputs (I) | 16 |
| Test outputs (T) | 4 |
| Safety outputs (OS) | 4 PNP semiconductor |
| Signalling outputs (O) | 4 |
| Port | USB |
| MTTFD | 614 years |
| PFHD | 1.32E-09 per hour |
| Mission time | 20 years |
| Response time | Below 30 ms |
| Size | 111.5 x 45 x 99 mm (H x L x W) |
| Supply | 24 Vdc plus or minus 15 percent, below 3 W without load |
| Output protection | Electronic short circuit protection on Tx and Ox; 0.5 A total |
| Start-up self-test | Below 2 s |
| Environment | 0 to plus 55 degrees Celsius, pollution degree 3 outside and 2 inside |
| Approvals | TUV SUD Z10 075157 0031, EC type examination M6A 075157 0032, UL E131787 |
Why semiconductor safety outputs matter
This code has no relay contacts in its safety stage. Its four safety outputs are PNP semiconductor outputs with electronic protection, so they switch silently and do not wear out through contact erosion. They are well suited to driving safety inputs of drives, safety PLC inputs and small contactors with low coil current. The catalogue gives the UL rating of semiconductor outputs as 24 Vdc at 500 mA for up to four outputs. Loads that need a mains voltage contact must be switched through an external contactor or relay, and in that case the monitoring of the contactor feedback is done with the external device monitoring function block available in the software.
How Pizzato CS MP202M0 differs from sibling codes
The 45 mm width is shared by eight modules, so the fastest way to separate them is by input and output count. The CS MP201M0 gives 8 inputs, 8 test outputs and 3NO relay contacts. The CS MP203M0 gives 12 inputs and a 3NO plus 1NO relay stage. The CS MP204M0 gives 12 inputs with 3NO. The CS MP206M0 gives only 8 inputs but 12 signalling outputs. The CS MP208M0 has 16 inputs like this code but 8 PNP safety outputs and no signalling outputs. The code described here is therefore the compromise: the maximum number of inputs in the narrow housing together with four PNP safety outputs and four signalling outputs, with the best MTTFD of the modules listed here at 614 years.
Applications across Oman and the GCC
Automated warehouses, bottling and canning lines, palletisers and robotic welding cells are common in industrial areas around Muscat, Sohar and Salalah. Many of them were built abroad and need local modification: another door, a new light curtain, an extra e-stop. A programmable module makes that change a matter of editing the program instead of rewiring relays. Packaging machinery makers in the region also use such modules in standard machine platforms, then export the program file as part of the documentation.
Programming workflow
- Install Gemnis Studio after registration on the manufacturer website.
- Drag sensors into the sensor zone, choose their contact type and define the test lines.
- Assemble the logic with function blocks and connect them to the output zone.
- Simulate the program on the desktop, then load it through the USB cable.
- Run the validation plan, protect the project with a password and file the reports.
Input circuit data to respect
The input circuits are 24 V at 5 mA, with signals below 8 V read as off and between 12 and 24 V read as on. The minimum signal duration is 10 ms, interference shorter than 0.4 ms is filtered, and the maximum input resistance is 100 ohm. Cable capacitance may be at most 470 nF to ground and between two conductors. These figures set the maximum length of the field wiring; in a long cable run use a cross-section that keeps resistance low and avoid running the safety cable next to motor power cables.
Planning a 16 input cell
Sixteen inputs sound like a lot until the devices are counted. A door switch with two channels takes two inputs, a light curtain with two OSSD outputs takes two, an e-stop with two contacts takes two, and a two-hand control takes four. Eight dual-channel devices therefore use the whole module. Group the devices by the zone they protect and decide which outputs react to which group: for instance, the door switches of cell A stop only the robot of cell A, while the e-stop stops the whole line. The four safety outputs can each be given a different logic, which is what lets one module serve several zones. Mark every input on the drawing with its terminal and keep that drawing next to the program file. During commissioning, actuate each device in turn and confirm in the software monitor that the expected input changes state, then confirm that only the intended outputs react. This simple routine finds swapped wires, wrong sensor types and misunderstood zones long before the cell is handed over to production.
Service
Keep a copy of the program and its password, document every revision and repeat the validation after changes. If the module has to be replaced, load the saved project and retest all functions, since the safety function is defined by the program as much as by the hardware.
Related items you may also need: Pizzato FD 1001 Metal Position Switch with Plunger | Pizzato FR 693 Safety Switch with Separate Actuator, 1NO+1NC | Pizzato FK 301 Position Switch with Plunger, Snap Action | All Pizzato products.
Before you order the Pizzato CS MP202M0
- To avoid a wrong delivery, compare the code on the nameplate of the installed unit with the Pizzato CS MP202M0 code on this page.
- The quotation for the Pizzato CS MP202M0 states the confirmed code, the condition of the unit and the lead time to site.
- The attached manufacturer datasheet covers the Pizzato CS MP202M0 ratings, dimensions and installation details.
- Delivery of the Pizzato CS MP202M0 is arranged to project sites in Oman and across the GCC, alongside the rest of our safety switches & guard locking range.
- A spare Pizzato CS MP202M0 on the shelf is a simple way to protect critical service from long lead times.
Documents and quotation
The catalogue chapter for the CS MP series is attached to this page and includes the module table, technical data and the terminal diagram of this code. To obtain a quotation, send an RFQ that names Pizzato CS MP202M0, the quantity, your project location in Oman or the GCC and any extra items you need.
Other Models in the CS MP Range
Seven Star LLC supplies models from the CS MP range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Pizzato CS MP201M0 Programmable Safety Module, Gemnis | Safety Switches & Guard Locking | View details |
| Pizzato CS MP202M0 Programmable Safety Module, 16 Inputs | Safety Switches & Guard Locking | You are viewing this model |
Datasheets & Documents
- Datasheet Pizzato CS MP202M0 Programmable Safety Module, 16 Inputs Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pizzato Elettrica is an Italian maker of position switches and safety devices, founded in 1984 as a manufacturer of position switches and based in Marostica, near Vicenza. It took the name Pizzato Elettrica in 1988 and added safety modules around 2002. The company designs and assembles its products in Marostica, where it opened a new 25,000 m² headquarters in 2019.
Seven Star LLC is an independent supplier in Muscat. We list Pizzato switches for machine builders and maintenance teams in Oman and the GCC.
Pizzato company profile
| Founded | 1984, Italy |
|---|---|
| Headquarters | Marostica, Italy |
| Name since | 1988 |
| Catalogue | More than 7,000 standard products |
| Product families | FR, FD and FK position switches, NG and NS safety interlocks, NX RFID safety switches, safety modules, foot switches |
Milestones
- 1984: Pizzato is founded.
- 1988: The company becomes Pizzato Elettrica.
- 2019: A new headquarters opens in Marostica.
Pizzato product series
Position switches include the FD 1001 metal switch with plunger, the FK 301 switch with plunger and snap action contacts, and the FR 1007 switch with adjustable roller lever.
Switches are chosen by the housing (metal or technopolymer), actuator, contact block and electrical connection. Snap action contacts switch quickly regardless of actuator speed, and positive opening contacts are used in safety circuits.
Plunger actuators suit short, straight movements against a cam or stop, while adjustable roller levers let the operating point be set on site and suit cams and moving parts that pass the switch. Metal housings stand up to heavy duty and impacts, and each data sheet states the IP rating, mechanical life and operating temperature range.
Where Pizzato switches are used
End of travel detection on machines, conveyors, doors and guards, cranes and lifting equipment.
Pizzato products we list
| Family | Examples |
|---|---|
| Automation Accessories | FD 1001 Metal Position Switch with Plunger, FK 301 Position Switch with Plunger, FR 1007 Position Switch |
Ordering Pizzato switches: what we need
Send the full article code, or the actuator type, contacts, housing and cable entry.
Facts checked against Pizzato's own timeline and EtherCAT member profile, October 2026.
Browse Pizzato products by category: Automation Accessories.
FAQ
Questions about the Pizzato CS MP202M0 Programmable Safety Module, 16
Answers from our engineering team on installation, compatibility and integration.
01How many inputs does the Pizzato CS MP202M0 have?
It has 16 safety inputs and 4 test outputs, in a housing 45 mm wide.
02What kind of safety outputs does the CS MP202M0 use?
Four PNP semiconductor safety outputs plus four signalling outputs, with no relay contacts in the safety stage.
03What are the safety figures of the CS MP202M0?
MTTFD is 614 years and PFHD is 1.32E-09 per hour, with a mission time of 20 years and limits of Maximum SIL 3, PL e and category 4.
04What is the response time of the CS MP202M0?
The system response time is below 30 ms.
05How is the CS MP202M0 configured?
With the Gemnis Studio software over the USB port, using graphical sensors and function blocks that can be simulated before loading.


















Reviews
There are no reviews yet.