Brand:

Pizzato CS AT-02V120 Timed Safety Module, 120 Vac

Description

Overview

Machines with heavy rotating parts need a safety relay that does not cut everything at the same moment. The Pizzato CS AT-02V120 is built for that job. It is a timed safety module from the CS AT-0 range, powered directly from 120 Vac, with screw terminals and an adjustable release time of 1 to 10 seconds in 1 second steps for its delayed contacts. Its outputs are two instantaneous normally open safety contacts, one instantaneous normally closed auxiliary contact and two delayed normally open safety contacts, and it is rated for safety functions up to SIL 3 and PL e. Seven Star LLC is an independent supplier serving Oman and the GCC.

Why the Pizzato CS AT-02V120 suits slow run-down machines

The longer delay window of range 2 is what separates this code from the 0.3 to 3 second version. A large fan, a centrifuge, a mixer with a heavy paddle or a conveyor with a loaded belt may need several seconds before the hazard has really ended. With a setting of, for example, 6 seconds, the instantaneous contacts open at the same moment as the emergency stop or guard switch, so the drive receives its stop command and brakes, while the delayed contacts hold the guard lock or the brake supply for the chosen time. Only after the dial time has elapsed do the delayed contacts open and permit entry. The adjustment is made on the front dial, and the catalogue gives the steps as 1 second.

Technical data of Pizzato CS AT-02V120

Item Catalogue value
Article Pizzato CS AT-02V120
Supply voltage 120 Vac, 50 to 60 Hz, tolerance plus or minus 15 percent
Consumption Below 10 VA
Delay range 1 to 10 s, steps of 1 s (code 2)
Terminals Screw terminals (code V)
Instantaneous contacts 2NO safety and 1NC auxiliary, category 4
Delayed contacts 2NO safety, category 3
Response time tA Below 300 ms
Release time tR1 Below 25 ms
Release time without supply Below 150 ms
Contact rating AC-15 3 A at 230 V; DC-13 4 A at 24 V; Ith 6 A
Sum of squared currents 72 A2 instantaneous, 36 A2 delayed
Minimum current 10 mA; contact resistance up to 100 milliohm
Insulation Ui 250 V, Uimp 4 kV, overvoltage category II
Temperature Minus 25 to plus 55 degrees Celsius
Housing PA 66, V0, IP40; terminal strip IP20

Differences from other CS AT-0 variants

  • Against the CS AT-01 codes, the adjustable window moves from 0.3 to 3 seconds to 1 to 10 seconds, so the resolution is coarser but the reach is longer.
  • Against the CS AT-03 and CS AT-04 codes, the maximum is 10 seconds instead of 30 or 300 seconds.
  • Against the 024 codes, the supply is 120 Vac rather than 24 V ac/dc, so no separate control power supply is required where a 120 V control circuit already exists.
  • Against the 230 codes, only the supply voltage differs, and the contact data stay the same.

Working with the inputs

The two input channels can be connected to emergency stop contacts, guard switches, magnetic safety sensors or OSSD outputs, and a single channel is allowed where the risk assessment permits it. Automatic, manual or monitored start is chosen by the wiring of S33 and S34. The PTC element protects the module from short circuits with a holding current of 0.5 A and has a response above 100 ms and a reset above 3 seconds, so if the module trips because of a wiring fault, allow a few seconds after correcting it. The cable resistance per input should stay below 50 ohm and the current per input is below 40 mA.

Applications in Oman and the GCC

Water treatment plants with large mixers, desalination sites with pump skids, food factories with spiral freezers and wood or metal workshops with big saws are typical places for a delayed safety relay. On sites where the control panel is already supplied at 120 V from a transformer, the Pizzato CS AT-02V120 avoids another power supply in the cabinet. Panel builders in the region also like that the same family covers 24, 120 and 230 volt supplies, which allows one wiring concept to be reused across projects.

Commissioning checklist

  1. Measure how long the machine really needs to reach a safe state, then add a margin and set the dial.
  2. Check that the supply on A1 and A2 is within 120 Vac plus or minus 15 percent.
  3. Wire the safety loop to the instantaneous and delayed safety contacts only, and the signalling contact to the PLC.
  4. Fit a 4 A fuse in the output circuit as stated in the data.
  5. Test each input channel separately, and confirm that the monitored start refuses to restart after a stuck button.

Service and spare parts

The module is sealed and is replaced as a whole. Compare the settings at every periodic test because a dial that has been moved changes the real stop time. Keep a documented record, and do not extend the delay beyond what the hazard analysis requires, since an unnecessarily long wait invites operators to defeat the guard.

Choosing the delay value sensibly

A frequent mistake is to set the dial at the maximum just to be safe. The delayed pair should open as soon as the hazardous motion has truly ended and not much later, because operators who wait too long start looking for ways to open the guard sooner. Run the machine, trigger a stop from the same condition that will be used in service, and time the run-down with a stopwatch or the drive diagnostics, with the heaviest realistic load and the warmest brakes. Add a margin that your risk assessment accepts and select the nearest 1 second step. Because the range ends at 10 seconds, a machine that needs longer than that belongs on a CS AT-03 or CS AT-04 code instead.

A simple wiring picture

Imagine a mixer with a hinged lid. A guard switch with two normally closed contacts feeds S11 to S12 and S21 to S22. The instantaneous contacts 13 to 14 and 23 to 24 open the line contactors of the motor. The delayed contacts 47 to 48 and 57 to 58 are placed in the supply of the lid lock, so the lock releases only when the delay has elapsed. The signalling contact 31 to 32 reports the state to the PLC, and a start button on S33 and S34 restores the circuit once the lid is closed again.

Related items you may also need: Pizzato FK 301 Position Switch with Plunger, Snap Action | Pizzato FR 693 Safety Switch with Separate Actuator, 1NO+1NC | Pizzato FR 1007 Position Switch, Adjustable Roller | All Pizzato products.

Pizzato CS AT-02V120 ordering checklist

  • When the Pizzato CS AT-02V120 replaces an installed unit, check the existing nameplate against the code on this page before ordering.
  • Every enquiry for the Pizzato CS AT-02V120 is answered with a written confirmation of the code, condition and expected lead time.
  • Use the attached datasheet to check the Pizzato CS AT-02V120 ratings, dimensions and connection details against your drawings.
  • We supply the Pizzato CS AT-02V120 as part of our safety switches & guard locking range to plants in Oman and the GCC.
  • For critical duty, keeping one Pizzato CS AT-02V120 as a site spare shortens downtime after a failure.

Documents and quotation

The catalogue sheet of the CS AT-0 family accompanies this page with the code structure, technical data and wiring diagrams. For a quotation, send an RFQ with Pizzato CS AT-02V120, the number of pieces, the delivery location in Oman or the GCC and any expansion modules or DIN rail accessories you want quoted together.

Other Models in the CS AT Range

Seven Star LLC supplies models from the CS AT range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Pizzato CS AT-01V024 Safety Module with Delayed ContactsSafety Switches & Guard LockingView details
Pizzato CS AT-02V120 Timed Safety Module, 120 VacSafety Switches & Guard LockingYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Pizzato CS AT-02V120 Timed Safety Module, 120 Vac Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pizzato Elettrica is an Italian maker of position switches and safety devices, founded in 1984 as a manufacturer of position switches and based in Marostica, near Vicenza. It took the name Pizzato Elettrica in 1988 and added safety modules around 2002. The company designs and assembles its products in Marostica, where it opened a new 25,000 m² headquarters in 2019.

Seven Star LLC is an independent supplier in Muscat. We list Pizzato switches for machine builders and maintenance teams in Oman and the GCC.

Pizzato company profile

Founded 1984, Italy
Headquarters Marostica, Italy
Name since 1988
Catalogue More than 7,000 standard products
Product families FR, FD and FK position switches, NG and NS safety interlocks, NX RFID safety switches, safety modules, foot switches

Milestones

  • 1984: Pizzato is founded.
  • 1988: The company becomes Pizzato Elettrica.
  • 2019: A new headquarters opens in Marostica.

Pizzato product series

Position switches include the FD 1001 metal switch with plunger, the FK 301 switch with plunger and snap action contacts, and the FR 1007 switch with adjustable roller lever.

Switches are chosen by the housing (metal or technopolymer), actuator, contact block and electrical connection. Snap action contacts switch quickly regardless of actuator speed, and positive opening contacts are used in safety circuits.

Plunger actuators suit short, straight movements against a cam or stop, while adjustable roller levers let the operating point be set on site and suit cams and moving parts that pass the switch. Metal housings stand up to heavy duty and impacts, and each data sheet states the IP rating, mechanical life and operating temperature range.

Where Pizzato switches are used

End of travel detection on machines, conveyors, doors and guards, cranes and lifting equipment.

Pizzato products we list

Family Examples
Automation Accessories FD 1001 Metal Position Switch with Plunger, FK 301 Position Switch with Plunger, FR 1007 Position Switch

Ordering Pizzato switches: what we need

Send the full article code, or the actuator type, contacts, housing and cable entry.

Facts checked against Pizzato's own timeline and EtherCAT member profile, October 2026.

FAQ

Questions about the Pizzato CS AT-02V120 Timed Safety Module, 120 Vac

Answers from our engineering team on installation, compatibility and integration.

01What is the delay range of the Pizzato CS AT-02V120?
Delay code 2 gives an adjustable release time of 1 to 10 seconds, set in steps of 1 second, for the two delayed contacts.
02What supply voltage does the CS AT-02V120 use?
The 120 code is powered from 120 Vac at 50 to 60 Hz with a tolerance of plus or minus 15 percent and a consumption below 10 VA.
03How many safety contacts does the CS AT-02V120 have in total?
It has four normally open safety contacts, two instantaneous and two delayed, plus one instantaneous normally closed auxiliary contact.
04Which category applies to the delayed outputs of the CS AT-02V120?
The catalogue gives category 4 for the instantaneous contacts and category 3 for the delayed contacts, both within PL e and SIL 3 limits.
05Does the CS AT-02V120 need an external fuse?
The catalogue data state an external protection fuse of 4 A for the output circuit and a thermal current of 6 A per branch.