Brand: Magnetrol
Magnetrol Modulevel P65 Pneumatic Level Controller
Description
Overview
Boiler drums, feedwater heaters and separators often need a level controller that can be isolated for service without shutting the plant down. The Magnetrol Modulevel P65 is built for that job. It is a pneumatic, displacement-actuated liquid level controller in an external flanged cage with side-to-side connections, and it converts the buoyant force on a displacer into an air signal in direct proportion to level.
A magnetic coupling links the displacer to the controller head, so the head can be taken off without breaking the pressure boundary. A range spring damps the displacer against surface turbulence, which keeps the output signal steady and spares the control valve from hunting.
Seven Star LLC is an independent supplier serving Oman and the GCC. Power, refining and chemical customers may ask us to quote the P65 with the head function, cage material and flange class they require.
What sets Magnetrol Modulevel P65 apart in the P6x range
The P6x flanged cage models share one controller head and differ in how the chamber attaches to the vessel. The P61 and P62 mount on top of the tank, the P63 and P64 have side and bottom connections, and the P65 and P66 have side and side connections. The P65 is therefore the model to choose when the tank has two nozzles on the same side that match the cage inlets, a common arrangement for retrofits and for quick isolation with two valves.
The catalogue lists flange classes of 150, 300 and 600 for this family, with either 1 1/2 or 2 inch NPT, socket weld or ANSI flanged outlets, and optional 3/4 inch NPT gauge glass tappings. A head that rotates 360 degrees lets piping come in from any direction.
Magnetrol Modulevel P65 technical data
| Parameter | Value |
|---|---|
| Process pressure (standard models) | Up to 4047 psig at 100 degrees Fahrenheit (279 bar at 38 degrees Celsius) |
| Temperature, stainless steel cage | Minus 150 to plus 700 degrees Fahrenheit (minus 101 to plus 371 degrees Celsius) |
| Temperature, carbon steel cage | Minus 20 to plus 700 degrees Fahrenheit (minus 29 to plus 371 degrees Celsius) |
| Specific gravity range | 0.11 minimum to 2.20 maximum |
| Interface detection | Minimum 0.10 specific gravity difference between liquids |
| Output signal | 3 to 15 or 6 to 30 psig (proportional and transmitter); 0 to 20 or 0 to 35 psig (differential gap) |
| Supply pressure | Up to 250 psig to the regulator, instrument quality air, regulator set 5 psig above maximum output |
| Air consumption | 3 SCFH at 9 psig output; 6 SCFH at 15 psig output |
| Response | 100 cubic inches of output volume in 3.2 seconds for a 3 to 15 psig rise |
| Level range | Fractional inches up to 10 feet (3 m), limited by displacer length |
| Wetted parts | 316 SS displacer, 304 or 316 SS trim, 316 SS or Inconel spring, carbon steel or 316 SS chamber |
| Housing | IP53 (IP55 on request), NEMA 1, 2, 3 and 3R |
| Control action | Direct or reverse |
| Mounting | External flanged cage, side/side connections, 150, 300 or 600 class |
| Cage connections | Two 1 1/2 or 2 inch NPT, socket weld or ANSI flange |
Control modes available
The same head can be supplied as a proportional controller, a transmitter, a transmitter with a receiver controller, a proportional plus integral controller or a differential gap controller. Proportional units hold the level within a band, integral action removes the offset so that the level is held at a point, and the differential gap version gives only fully open or fully closed outputs between two switching points. Each can be direct acting, where pressure rises with level, or reverse acting.
Electric limit switches can be added to give high and low alarms rated to 120 V with 1/4 amp switching, and a pneumatic to current converter can provide 4 to 20 mA or 10 to 50 mA from the air signal.
Applications
- Boiler level control and steam generator feedwater heater regulation.
- Drip pot condensate level control and flash tank level transmitters.
- Fractionating column and ethanolamine level duties in refineries.
- Vent gas scrubber level control.
- Interface control when the density difference of the liquids is at least 0.10.
Installation and calibration
Install the cage on the two vessel nozzles with isolation valves, connect a filtered, regulated air supply, and fit the optional filter regulator 06-9501-002 and gauge 06-9501-003 if they are not already supplied. Calibrate before installation by substituting weights for the displacer, or in place with the displacer by adjusting the head. The built-in visual indicator shows percent span and does not depend on air.
Because the controller can be calibrated without moving the tank level, commissioning time is short.
Planning the nozzles and isolation
When specifying an external cage unit, start with the vessel drawing. The two cage connections must sit above and below the expected control range, and the spacing between them determines the level range the displacer can follow. Add an isolation valve to each branch so the cage can be drained and the head serviced while the vessel stays in service, and consider a vent and drain on the chamber for commissioning and for pressure tests. Specify the flange class from the design pressure and temperature of the vessel, remembering that higher classes carry higher pressure ratings.
Materials are chosen to suit the liquid. The cage can be carbon steel or 316 stainless steel, the displacer is 316 stainless steel, and springs are 316 stainless steel or Inconel. Tell us the process liquid, its specific gravity at operating temperature and whether an interface is involved, so that the displacer and spring can be matched correctly. Where the liquid is corrosive or the pressure is very high, the heavy duty construction rated to 4047 psig should be discussed with the manufacturer before ordering.
Maintenance
Service the head without depressurising the cage. Check the supply air quality, drain the filter, inspect the relay and the nozzle and verify output at zero and full span. Keep the displacer clean, and change range springs only according to the manufacturer’s data.
Related items you may also need: Magnetrol Z30-9166-002 Fieldbus Wiring Board for Eclipse 706 GWR | Magnetrol Z31-2858-001 PROFIBUS PA Electronic Module for Eclipse 706 | Magnetrol 089-7259-001 Echotel 961 102-265 VAC Electronics Module | All Magnetrol products.
Before you order the Magnetrol Modulevel P65
- To avoid a wrong delivery, compare the code on the nameplate of the installed unit with the Magnetrol Modulevel P65 code on this page.
- The quotation for the Magnetrol Modulevel P65 states the confirmed code, the condition of the unit and the lead time to site.
- The attached manufacturer datasheet covers the Magnetrol Modulevel P65 ratings, dimensions and installation details.
- Delivery of the Magnetrol Modulevel P65 is arranged to project sites in Oman and across the GCC, alongside the rest of our level switches range.
- A spare Magnetrol Modulevel P65 on the shelf is a simple way to protect critical service from long lead times.
Documents and quotation
The Magnetrol catalogue 48-110 serves as the datasheet for the Magnetrol Modulevel P65. Send your RFQ with the part number Magnetrol Modulevel P65, the flange class, cage material and control mode, and we will confirm availability for Oman and the GCC.
Datasheets & Documents
- Datasheet Magnetrol Modulevel P65 Pneumatic Level Controller Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol Modulevel P65 Pneumatic Level Controller
Answers from our engineering team on installation, compatibility and integration.
01What type of controller is the Magnetrol Modulevel P65?
It is a pneumatic displacement-actuated level controller in an external flanged cage with side-to-side connections, giving an air signal in proportion to liquid level.
02What output signals does the Modulevel P65 provide?
Proportional and transmitter versions give 3 to 15 or 6 to 30 psig, and differential gap versions give 0 to 20 or 0 to 35 psig.
03What pressure and temperature can the Modulevel P65 handle?
Standard models handle up to 4047 psig at 100 degrees Fahrenheit and from minus 150 to plus 700 degrees Fahrenheit with a stainless steel cage.
04Can the Modulevel P65 detect interface levels?
Yes, if the specific gravity difference between the two liquids is at least 0.10 and the displacer stays submerged and across the interface.
05Can the head of the Modulevel P65 be serviced without shutdown?
The controller head can be removed without disturbing the pressure boundary, so it can be serviced or replaced without shutting down the process.