Brand: Magnetrol
Magnetrol Echotel 355 Non-Contact Ultrasonic Level Transmitter
Description
Overview
Measuring a liquid level without touching the liquid is often the most practical choice for corrosive, sticky or sensitive media. The Magnetrol Echotel 355 is a two-wire, loop-powered, non-contact ultrasonic transmitter for liquid level, volume and open channel flow. It reaches out to a maximum range of 20 feet, which is 6 metres, and it is configured with four push buttons and a two-line display, with HART communication and PACTware as options for remote setup. Seven Star LLC is an independent supplier serving Oman and the GCC.
Transducer and signal processing in Magnetrol Echotel 355
A powerful 60 kHz transducer sends pulses toward the surface and the electronics time the echo. The speed of sound changes with air temperature, so the transducer also measures temperature and compensates. The unit has a narrow 10 degree conical beam and a 10 inch, or 250 millimetre, blocking distance, and the beam radius grows from 5.2 inches at 5 feet to 21 inches at 20 feet. A patent-pending temperature compensated echo rejection technique separates the true surface echo from false targets, and dynamic baseline noise compensation keeps readings stable under electromagnetic noise.
Technical data of Magnetrol Echotel 355
| Parameter | Catalog value |
|---|---|
| Supply voltage | 6 to 30 V DC (general purpose, flameproof); 16 to 28.4 V DC (intrinsically safe) |
| Power consumption | Less than 1 W |
| Output | 4-20 mA with HART; usable 3.8 to 20.5 mA (NAMUR NE 43) |
| Diagnostic alarm | 3.6 mA, 22 mA or hold |
| Loop resistance | 400 ohms at 24 V and 20 mA |
| Maximum range | 20 feet (6 m) |
| Minimum range | 13 inches (330 mm) |
| Blocking distance | 10 inches (250 mm) |
| Accuracy | Greater of plus or minus 0.2 percent of range or 0.24 inch (6 mm) |
| Resolution | 0.1 inch (2.5 mm) |
| Response time | Less than 1 second typical; warm-up 25 seconds |
| Process connection | 2 inch NPT |
| Process temperature and pressure | Minus 40 to plus 80 degrees C; 0 to 3 bar |
| Transducer material | Polypropylene or Kynar Flex (PVDF) |
| Housing | Cast aluminum (IP66, 1.5 kg) or Lexan (IP67, 0.7 kg) |
How Magnetrol Echotel 355 differs from other Magnetrol level transmitters
Where the Echotel 355 uses sound, the Pulsar R82 and R86 use radar, and the Eclipse 706 is a contact guided wave radar that rides along a probe. The 355 suits open or nearly atmospheric tanks and channels within 6 metres and a pressure of up to 3 bar, so higher process pressures, longer ranges or heavy vapour call for one of the radar models. Among the Echotel family, the 355 is the transmitter, whereas the 910 and 961 are point level switches.
Where it is used
The catalog lists chemical storage tanks, pond and river level, paint, ink and solvent tanks, industrial wastewater, volume in batch and day tanks and open channel flow in weirs and flumes. In Oman, typical targets are desalination chemical dosing tanks, wastewater lift stations, wadi and drainage channel gauging and water treatment sumps. The transmitter stores 35 flume and weir curves, plus a 20-point custom table, for flow measurement.
Performance in difficult tanks
The catalog gives performance multipliers for conditions such as surface agitation, foam, vapour and condensation. Multiply the 20 foot maximum by each applicable factor to find the usable range: a smooth glass-like surface is 1.0, slight choppiness 0.9, heavy agitation 0.8, and a slight vortex 0.7. This is why you should state the media and conditions when asking for a recommendation.
Selecting between ultrasonic and radar for your tank
The decision usually starts with the vessel. An open or vented tank with a calm surface and a modest height is a very good fit for the ultrasonic principle, which is simple, economical and unaffected by the dielectric constant of the liquid. Heavy vapour, foam, condensation or rapid temperature layers reduce the strength of the echo, which is exactly why the catalog supplies performance multipliers to shorten the allowable range in such conditions. If the tank is pressurised, very tall, or contains a liquid that produces dense vapour, a radar transmitter is the more robust choice. The ability of this transmitter to compute volume from common tank shapes saves a lot of manual strapping table work, and the 20-point custom table is useful for horizontal or cone-bottom tanks.
Signal and loop considerations
The 4-20 mA signal follows the NAMUR NE 43 convention, so a value of 3.8 to 20.5 mA is a measurement and anything outside indicates a fault. The user chooses whether a fault drives the current to 3.6 mA, 22 mA or holds the last value, and the damping can be adjusted from 1 to 60. The loop must supply at least the minimum voltage at the terminals of the transmitter and respect the 400 ohm limit at 24 volts, so check the barrier resistance in intrinsically safe installations. HART communication lets technicians view echo waveforms and trends with PACTware without climbing the tank.
Mounting and commissioning
Install the transducer vertically, at least the blocking distance above the highest level, and away from inlet streams and tank walls. Enter tank height and shape through the keypad or PACTware. The transmitter provides two seven-digit flow totalizers, one resettable and one not. Check the reading against a dip stick and adjust the offset if needed.
Why a loop-powered design helps
Because the transmitter draws less than one watt and sends its measurement on the same two wires that supply it, installation needs no separate power cable, no signal cable and no mains terminations at the tank. In older plants that already have 4-20 mA loops from float or bubbler systems, the existing wiring can often be reused. Fewer conductors also mean fewer places for moisture or corrosion to cause faults, which matters in humid coastal sites. The cost saving is greatest when many tanks are scattered over a large area, as in water distribution networks and chemical dosing stations.
Care
Keep the transducer face free of heavy deposits and condensate, check the loop wiring and review diagnostics. Replacement electronic modules and transducer kits for the Echotel 355 are separate service items.
Ordering notes for Magnetrol Echotel 355
The model code 355 is followed by position codes for power, output, approval, housing and transducer, such as 355-510A-AXX. State the approval needed, ATEX or IECEx and FM, as well as the housing and transducer material, and confirm the full order code on the nameplate.
Related items you may also need: Magnetrol 089-5533-001 Stem and Spring Kit, 0.23-0.54 SG, Modulevel | Magnetrol Z31-2849-002 Fieldbus Electronic Module for Eclipse 706 GWR | Magnetrol Z31-2865-002 Wiring Board for Pulsar R80, Explosion-Proof | All Magnetrol products.
Documents and quotation
The product catalog for the Magnetrol Echotel 355 is attached to this page. Please send your RFQ with Magnetrol Echotel 355, the code and your delivery location in Oman or the GCC.
Datasheets & Documents
- Datasheet Magnetrol Echotel 355 Non-Contact Ultrasonic Level Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol Echotel 355 Non-Contact Ultrasonic Level
Answers from our engineering team on installation, compatibility and integration.
01What is the maximum range of the Magnetrol Echotel 355?
The maximum range is 20 feet (6 m) with a minimum range of 13 inches (330 mm) and a blocking distance of 10 inches (250 mm).
02How is the Magnetrol Echotel 355 powered?
It is a two-wire loop-powered transmitter running on 6 to 30 V DC, or 16 to 28.4 V DC in the intrinsically safe version, with 4-20 mA and optional HART.
03What accuracy does the Echotel 355 achieve?
Accuracy is the greater of plus or minus 0.2 percent of range or 0.24 inch (6 mm), with 0.1 inch resolution and a response under 1 second.
04Can the Magnetrol Echotel 355 measure open channel flow?
Yes. It holds 35 flume and weir curves, a 20-point custom table and a generic discharge flow equation, with two seven-digit totalizers.
05What transducer materials does the Echotel 355 offer?
The 60 kHz transducer comes in polypropylene or Kynar Flex PVDF, with a 2 inch NPT process connection for 0 to 3 bar.


















Reviews
There are no reviews yet.