Brand:

Magnetrol 089-9125-004 Echotel 355 HART Electronic Module Lexan

Description

Magnetrol 089-9125-004: HART electronic module for the Echotel 355 Lexan housing

Where the previous module serves plants that only read milliamps, the Magnetrol 089-9125-004 is the one with HART digital communication, for the Lexan plastic housing of the Echotel 355. It allows the transmitter to be configured with a HART communicator or an asset management system in addition to the keypad.

The manual explains that HART uses Bell 202 frequency shift keying on the 4 to 20 mA loop and needs a 250 ohm load resistance; it also lists HART version 5.x compatibility. That is why the module is the natural choice for newer control systems and why the 355 model number has the option “4-20 mA with HART”. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Key facts about 089-9125-004

  • Lexan housing module with the HART option, item 2 of the replacement parts table.
  • HART version 5.x compatible, with the Display, HART and Diagnostics menus described in section 2.6.
  • Needs a load of at least 250 ohm for HART configuration.
  • Retains the keypad menus for Level, Volume and Open Channel Flow applications.

Technical data for 089-9125-004

Parameter Value
Part number 089-9125-004
Manual item 2, electronic module with HART for Lexan housing
Digital communication HART version 5.x compatible
Minimum loop load for HART 250 ohm
Output 4 to 20 mA; 3.8 to 20.5 mA usable (NAMUR NE 43)
Diagnostic alarm Selectable 3.6 mA, 22 mA or HOLD
Damping Adjustable 1 to 60
Loop resistance 400 ohm at 24 VDC and 20 mA; 350 ohm at 24 VDC and 22 mA
Power consumption Less than 1 watt
Warm-up time 25 seconds
Display 2-line by 16-character LCD
Keypad 4 push-buttons, menu driven
Ambient temperature -40 to +80 C
Accuracy Greater of 0.2 percent of range or 0.24 inch (6 mm)

Where 089-9125-004 is used in oil and gas, utilities, water and manufacturing

Wastewater works, desalination plants and chemical dosing stations in the GCC increasingly commission their instruments over HART, because it lets maintenance teams change range, damping or the diagnostic alarm without climbing the tank. The Lexan housing suits corrosive vapors.

The 355 can measure level, volume and open channel flow through flumes and weirs; with the HART module the flow equation parameters and totalizer settings can be edited from the host as well as at the keypad.

How 089-9125-004 differs from other Echotel 355 modules

Module Variant
089-9125-001 Aluminum, no HART
089-9125-002 Lexan, no HART
089-9125-003 Aluminum, HART
089-9125-004 Lexan, HART (this part)

The HART module 089-9125-004 differs from 089-9125-003 only in the housing it is intended for. For a plant that stocks both housing types, a mix-up produces a module that does not seat in the other housing.

Selection and compatibility for 089-9125-004

  • Housing code 6 (Lexan) in the model number.
  • Model number output code 1 (4 to 20 mA with HART).
  • Use a HART-compatible loop with at least 250 ohm.
  • Match the Lexan cover 003-1226-003 and O-ring 012-2616-001 for the housing.

Installation and commissioning of 089-9125-004

Switch off the loop, handle the module with ESD precautions, fit it, and re-enter the configuration. The HART connection diagram in section 2.6.1 shows the communicator across the loop with the load resistor; the Test 4-20 Loop function lets any value from 3.6 to 22.0 mA be forced for checking the DCS input.

Maintenance and spares planning

Store the module with a note of its HART revision for the loop file. After replacement, print or save the configuration data sheet from section 3.7 of the manual so the next change is traceable.

Transducer and application data the 089-9125-004 works with

The module does not measure alone; it drives the ultrasonic transducer of the Model 355. The values below are the transducer and performance figures printed in the manual, and they define what the module can achieve on a tank.

Parameter Value
Maximum range 20 feet (6 m) under ideal conditions
Minimum range 13 inches (330 mm)
Blocking distance 10 inches (250 mm)
Frequency 60 kHz
Beam angle 10 degree conical
Process connection 2 inch NPT
Process temperature -40 to +175 F (-40 to +80 C)
Process pressure 0 to 43.5 psig (0 to 3 bar)
Accuracy Greater of 0.2 percent of range or 0.24 inch (6 mm)
Repeatability 0.125 inch (3 mm)
Resolution 0.1 inch (2.5 mm)
Output 4 to 20 mA, optional HART, 3.8 to 20.5 mA usable (NAMUR NE 43)
Minimum measurement 3 inches (76 mm)
Linearity 0.4 inch (10 mm)
Response time Less than 1 second, typical
Warm-up time 25 seconds
Display 2-line by 16-character LCD with 4-button keypad
Diagnostic alarm Selectable 3.6 mA, 22 mA or HOLD
Power consumption Less than 1 watt

The speed of sound used by the 355 is 331.45 m/s at 0 C and the unit compensates for temperature, so a HART read of the temperature extrema and echo strength helps diagnose a poor reading. The manual lists diagnostics such as echo strength, number of echoes, echo missing time and echo profile, which are available from the keypad and the HART menu. Error messages include High Temp and Low Temp when the transducer leaves its -40 to +80 C window, and Initializing during the warm-up period.

Documents and quotation

The manufacturer manual 51-661 for the Echotel Model 355 is attached to this page as the datasheet for 089-9125-004; its section 3.4 holds the parts table and section 3.6 the specifications used above. To receive a quotation, send an RFQ giving part number 089-9125-004, quantity, the model number printed on the transmitter nameplate and the delivery location in Oman or the GCC.

Ordering Checklist for the Magnetrol 089-9125-004

Before you ask for a quotation for the Magnetrol 089-9125-004, check the full order code on the nameplate of the unit you are replacing, the supply voltage, and the process or signal ranges your system expects. If this is an upgrade rather than a like-for-like swap, tell us the existing make and model so that mounting, wiring and connection details can be checked against the ultrasonic level transmitters already installed. For multi-unit orders, list the quantity per site and the delivery location in Oman or the wider GCC, so packing, paperwork and lead time can be confirmed in a single quotation.

Installation and Commissioning Planning

Planning ahead shortens downtime when a Magnetrol 089-9125-004 goes into service. Confirm the available mounting space, cable entry or process connection, and the tools and spare seals needed on the day. Keep the existing configuration or calibration data so the new unit can be set up to match, and check that loop drawings and the asset register are updated after the swap. If the installation has to fit a short shutdown window, tell us the date when you request a quotation so that delivery of the Magnetrol equipment can be planned around it.

Other Models in the Magnetrol 355 Module Range

Seven Star LLC supplies models from the Magnetrol 355 Module range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Magnetrol 089-9125-004 Echotel 355 HART Electronic Module LexanUltrasonic Level TransmittersYou are viewing this model
Magnetrol 089-9125-002 Echotel 355 Electronic Module Lexan, No HARTUltrasonic Level TransmittersView details
Datasheets & Documents
  • PDF Datasheet Magnetrol 089-9125-004 Echotel 355 HART Electronic Module Lexan Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.

Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.

Magnetrol company profile

Established 1932, USA; headquarters in Aurora, Illinois
Ownership Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group
Product families Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand)
Applications Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection

Milestones

  • 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
  • 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
  • 2021: AMETEK acquires Magnetrol on 29 March.

Magnetrol products we list

Model Principle Typical use
Eclipse 706 Guided wave radar Level and interface in separators, chambers and boiler drums, unaffected by changing density
Pulsar R80 80 GHz FMCW radar Narrow-beam non-contact level in tanks with internals and in solids
Pulsar R86 26 GHz radar Non-contact level in process and storage vessels
Pulsar R96 6 GHz radar Non-contact level where vapour, foam or condensation are present
E4 Modulevel Displacer Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units
Echotel 961/962 Ultrasonic gap switch High and low level alarms and pump protection
Thermatel TD1/TD2 Thermal dispersion switch Flow and no-flow detection and level switching for liquids and gases

Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.

Where Magnetrol instruments are used

In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.

Ordering Magnetrol instruments: what we need

Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.

Facts checked against Magnetrol and AMETEK company information, October 2026.

FAQ

Questions about the Magnetrol 089-9125-004 Echotel 355 HART Electronic

Answers from our engineering team on installation, compatibility and integration.

01What is Magnetrol 089-9125-004?
It is the HART electronic module for the Lexan housing of the Echotel 355, item 2 in manual 51-661.
02Which HART version does it support?
The manual specifies HART version 5.x compatibility.
03What load resistance does HART need?
The manual states that a minimum 250 ohm line load resistance is required.
04Can the loop be tested from the module?
Yes, the Test 4-20 Loop function lets any value from 3.6 to 22.0 mA be entered to test the loop output.
05Can Seven Star LLC supply 089-9125-004 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location.