Overview

A heater bank with many zones is cumbersome to build from single-loop controllers, and Autonics TM4-N2SB solves that with one DIN-rail module that regulates four temperature loops. It is the basic module of the Autonics TM Series modular multi-channel PID temperature controllers. The ordering information decodes the model: TM4 gives four channels, N means no alarm output on the 4-channel version, 2 selects a 24 V DC supply, S selects an SSR drive control output, and B marks the basic module that carries the power, communication and connector, as opposed to an expansion module. Seven Star LLC is an independent supplier serving Oman and the GCC.

Several modules can be linked side by side so that a single supply and a single RS485 line serve the whole group, which cuts wiring and panel space on extruders, moulding machines and thermal process lines.

Advantages of Autonics TM4-N2SB

  • Four independent PID loops in one module with synchronous 100 ms sampling.
  • Universal inputs covering K, J, E, T, B, R, S, N, C, G, L, U and Platinel II thermocouples and JPt100, DPt100, DPt50, Cu50, Cu100 and Nickel 120 ohm RTDs.
  • SSR drive output of 22 V DC plus or minus 3 V at 30 mA or less on each of the four channels.
  • RS485 Modbus RTU communication through the basic module, with parameter setting and monitoring from the DAQMaster software.
  • Power and communication connector fitted only to the basic module, so expansion modules plug onto it through a side connector.
  • Control types ON/OFF, P, PI, PD and PID, with auto-tuning for loop setup.

Technical data for Autonics TM4-N2SB

Parameter Value
Model TM4-N2SB
Channels 4
Module type Basic module
Power supply 24 V DC, 90 to 110 percent of rated voltage
Power consumption 5 W or less at maximum load
Sampling period 100 ms (4 channels synchronous)
Control output SSR drive, 22 V DC plus or minus 3 V, 30 mA or less
Alarm output None on this code
Communication RS485, Modbus RTU
Control methods ON/OFF, P, PI, PD, PID
Sensor input Thermocouple and RTD, selectable per channel
Ambient temperature minus 10 to plus 50 degrees C
Mounting DIN rail or bolts (M4)

How TM4-N2SB differs from other TM variants

Three code letters set the range. The first digit chooses 2 or 4 channels: TM2 has two channels with 50 ms sampling, while TM4 has four channels and 100 ms sampling. The alarm field chooses no alarm (N), alarm output 1 or alarm outputs 1 and 2 on the two-channel version, so a code such as TM2-1 adds alarm contacts that the TM4 here does not have. The output field is R for relay, S for SSR drive, or C for selectable current or SSR drive, and a relay version provides 250 V AC 3 A (1a) outputs. The last letter picks basic (B) or expansion (E) structure.

Thus Autonics TM4-N2SB has siblings TM4-N2RB with relays, TM4-N2CB with current or SSR drive, and expansion modules such as TM4-N2SE that have no power or communication connector of their own and must be used with a basic module.

Applications

In Oman and GCC plants the TM Series is used on multi-zone heaters of plastic extruders and injection moulding barrels, sealing and packaging machines, curing ovens, hot-runner systems and process heating skids. The SSR drive version works with solid-state relays on heater loads, giving quiet and long-life switching compared with mechanical relays.

Selection and compatibility notes

Choose SSR drive output only if you will fit external solid-state relays; the controller drives them but does not switch a heater itself. If the loads must be switched by contactors, choose the relay model. Confirm the sensor types per channel and the supply of 24 V DC, which must be insulated and limited voltage or Class 2. The module needs space around it for heat radiation, and warm-up of more than 20 minutes is recommended for accurate measurement.

Installation and commissioning

Install the DIN rail vertically, hook the module on the rail and press it down until it locks, and fit end clamps. When expanding, remove the end cover, insert the side connector and tighten the modules together. Set each channel’s input type, range and control output, then run auto-tuning for every loop of Autonics TM4-N2SB using the front keys or the DAQMaster software over RS485.

Group wiring and supply planning

Because only the basic module carries the power and communication connector, planning a multi-zone panel is straightforward. The installation page of the manual shows a basic module with side-connected expansion modules, and it specifies a maximum power of 155 W when 31 units at 5 W each are connected, which is the figure to use when sizing the 24 V DC supply. The sensor input connector and the control output connector are separate plug-in parts, so a module can be exchanged without rewiring each sensor. The manual also asks for a ferrite bead at each end of the communication line and twisted-pair wire, and it says the communication line must not run together with the power line, advice that matters in heater panels where SSR output cables carry switched loads. With four channels per module and the possibility of linking many modules, a 40-zone extruder or oven can be controlled from one RS485 line into a PLC or SCADA system.

Maintenance

Check terminals for tightness on schedule, keep the ventilation clear, and consult the error indications in the manual, such as input open or out-of-range indicators, when a loop fails.

Ordering notes for Autonics TM4-N2SB

Quote TM4-N2SB and the quantity, and tell us how many zones you have so that we can propose a basic module with the right number of expansion modules.

Related items you may also need: Autonics E40S6-2500-6-L-5 Rotary Encoder Incremental | Datakom DKM-409 Network Analyser with Scopemeter | JUMO DICON touch Process and Program Controller | All Autonics products.

Documents and quotation

The TM Series product manual is attached to this listing. To request pricing, send part number TM4-N2SB, the quantity and your delivery location in Oman or the GCC through the RFQ form and we will confirm availability and lead time.

Datasheets & Documents
  • PDF Datasheet Autonics TM4-N2SB 4-Channel PID Temperature Controller Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Autonics is a South Korean maker of sensors and controllers, founded in 1977 as a small engineering business making controllers for looms. It took the Autonics name in 1988 and opened a new corporate headquarters in Busan in 2014. Autonics makes proximity and photoelectric sensors, rotary encoders, temperature controllers, counters, timers and stepper motor systems, with factories in Busan and Yangsan.

Seven Star LLC lists the Autonics E40S6-2500-6-L-5 incremental rotary encoder and supplies Autonics sensors and control devices in Oman and the GCC.

Autonics company profile

Founded 1977, South Korea
Current name Autonics, since 1988
Headquarters Busan, South Korea
Factories Busan and Yangsan
Product families E40 and E50 rotary encoders, PR proximity sensors, BJ photoelectric sensors, TK temperature controllers

Milestones

  • 1977: The company is founded.
  • 1988: Renamed Autonics Corporation.
  • 2014: Opens its Busan headquarters.

Reading the Autonics E40S encoder code

E40S is the 40 mm diameter shaft-type incremental encoder, and the 6 that follows is the 6 mm shaft. 2500 is the resolution in pulses per revolution. The next 6 means six output signals: A, B and Z with their inverted signals. L is a line driver output and the final 5 is a 5 V DC supply. The same 40 mm body is made in hollow shaft form as the E40H and E40HB series.

Where Autonics encoders are used

Servo and spindle feedback, conveyor length measurement, packaging and printing machines.

Ordering Autonics encoders: what we need

Send the complete model string from the label. If it is worn off, give the body and shaft diameter, pulses per revolution, output type, supply voltage and cable or connector style.

Facts checked against Autonics corporate profiles, October 2026.

FAQ

Questions about the Autonics TM4-N2SB 4-Channel PID Temperature

Answers from our engineering team on installation, compatibility and integration.

01What does TM4-N2SB mean?
TM Series 4-channel module, no alarm output, 24 V DC supply, SSR drive output, basic module.
02How many channels does it control?
Four independent PID temperature loops with synchronous sampling of 100 ms.
03What control output does TM4-N2SB have?
An SSR drive output of 22 V DC plus or minus 3 V at 30 mA or less on each channel.
04Does it communicate with a PLC or PC?
Yes. The basic module has RS485 Modbus RTU communication and works with the DAQMaster software.
05Can it be expanded?
Yes. Expansion modules connect through the side connector to a basic module, and the installation page of the manual gives a power budget for up to 31 modules in one group.