Brand:

Bürkert 418762 Type 8025 Paddle Wheel Insertion Flowmeter

Description

Overview

Bürkert 418762 is the article number of a compact Type 8025 paddle-wheel insertion flowmeter from Bürkert. It is the 12 to 36 V DC version with a short Hall sensor, a 4 to 20 mA two-wire current output plus a pulse output, and a female cable plug to DIN EN 175301-803. The meter is not a stand-alone pipe section: it is a measuring head that screws into a Type S020 insertion fitting, which is chosen separately for the pipe size and material. Seven Star LLC is an independent supplier serving Oman and the GCC.

Insertion paddle-wheel meters are a cost-effective way to monitor water, cooling circuits and clean chemical lines in large pipes, because one device and one fitting cover pipe diameters from DN 20 up to DN 400.

Main features of Bürkert 418762

  • Paddle wheel measuring principle with a PVDF wheel and sensor armature and an Al2O3 ceramic axis and bearing.
  • Flow measuring range of 0.5 to 75000 l/min and a velocity range of 0.3 to 10 m/s.
  • Large 8-digit alphanumeric LCD, 15 by 60 mm, with 9 mm high characters.
  • Housing and cover in PC, with FKM sensor seal fitted as standard and a spare EPDM seal set supplied.
  • DC reverse polarity and overvoltage protection.
  • Delivered with a stopper for the unused M20 x 1.5 cable gland and a mounting instruction sheet.

Technical data for Bürkert 418762

Parameter Value
Article number 418762
Type 8025 compact insertion flowmeter
Supply voltage 12 to 36 V DC
Sensor variant Hall, short
Output 4 to 20 mA (2-wire) plus pulse
Electrical connection female cable plug, DIN EN 175301-803
Pipe range DN 20 to DN 400 with S020 fitting
Flow rate range 0.5 to 75000 l/min
Flow velocity 0.3 to 10 m/s
Deviation with teach-in plus or minus 1 percent of reading at the teach-in flow
Deviation with standard K factor plus or minus 2.5 percent of reading
Linearity plus or minus 0.5 percent of full scale
Repeatability plus or minus 0.4 percent of reading
Fluid pressure max. PN 10
Viscosity max. 300 cSt
Solids max. 1 percent, particle size max. 0.5 mm
Process connection G 2 for use with Type S020 fitting

How 418762 differs from other 8025 variants

The Type 8025 datasheet lists a family of flowmeters, batch controllers and remote transmitters. Within the compact flowmeters, the long-sensor version of the same 2-wire output is 418763, the version with two cable glands is 418802, and the UL Recognized equivalent of Bürkert 418762 is 570457. The 3-wire version with pulse and two relays is 418778, and the 115 or 230 V AC versions start at 418423. A battery-powered indicator and totalizer without outputs is 418403.

The choice of short or long Hall sensor depends on the fitting length for the pipe size, so confirm it with the S020 data before ordering. This article suits applications that send a 4 to 20 mA signal to a PLC over two wires, with the pulse output available for totalising.

Applications

Typical installations in Oman and the GCC include chilled and cooling water headers in district cooling and power plants, process water and desalination make-up lines, irrigation mains, and clean chemical dosing. The compact format and loop-powered output make it simple to retrofit into a plant that already runs 24 V DC loops.

Selection and compatibility notes

The meter works only with a Type S020 insertion fitting, whose material (PVC, PP, PVDF, stainless steel or brass) sets the fluid temperature: PVC allows 0 to 50 degrees C, PP up to 80 degrees C, and PVDF, stainless steel or brass minus 15 to plus 80 degrees C. Ensure the fluid is relatively clean, since the datasheet limits particles to 1 percent and 0.5 mm. For hazardous areas or low-flow tasks, other Bürkert flow sensors named in the datasheet are more appropriate.

Installation and commissioning

Fit the S020 fitting in a straight pipe section with adequate inlet and outlet runs, insert Bürkert 418762, tighten the union nut and connect the cable plug. Use shielded cable up to 50 m with a temperature rating above 80 degrees C. Apply the teach-in procedure at a known flow to reach the 1 percent deviation figure, or set the K factor of the fitting for the standard 2.5 percent.

Display, totalisers and power

The 8-digit alphanumeric display with 15 segments per character shows flow rate and totals, and the datasheet states that every device in the flowmeter ordering chart has at least two volume totalisers. Power must come from a limited power source according to UL and EN 62368-1 or a limited-energy circuit according to UL and EN 61010-1, so use a certified 24 V supply when you specify Bürkert 418762 for panels that will be inspected by a third party. If the application must dose a defined quantity instead of only metering it, ask us about the compact batch controller version of the Type 8025, which adds digital inputs and transistor outputs.

Maintenance

Remove the insertion unit periodically to clean the paddle wheel of deposits. Inspect the ceramic axis for wear and renew the FKM seal when removing the sensor. Keep the lid closed so that moisture does not enter the PC housing.

Ordering notes for Bürkert 418762

Quote 418762 in your RFQ and also tell us the pipe diameter and material so that we can include the correct S020 fitting. State if you need the UL Recognized version or a different output.

Related items you may also need: Bürkert Type 6026 Direct-Acting 2/2-Way Plunger Solenoid Valve | Bürkert Type 8681 Control Head for Hygienic Process Valves | KRACHT VC 0.2 H2E3R2LM Gear Flow Meter | All Bürkert products.

Documents and quotation

The Type 8025 datasheet is attached to this listing. To request pricing, send part number 418762, the quantity and your delivery location in Oman or the GCC through the RFQ form and we will confirm availability and lead time.

Datasheets & Documents
  • PDF Datasheet Bürkert 418762 Type 8025 Paddle Wheel Insertion Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bürkert is a German family-owned maker of fluid control systems, headquartered in Ingelfingen, Baden-Württemberg. Christian Bürkert founded the company in 1946, and it is known for solenoid valves, process and control valves, flow and analytical sensors, and mass flow controllers. Its products serve water treatment, hygienic processing, gas handling and laboratory applications.

Seven Star LLC lists Bürkert valves and valve automation devices and supplies Bürkert solenoid valves and spare parts to plants in Oman as an independent supplier.

Bürkert company profile

Founded 1946, by Christian Bürkert
Headquarters Ingelfingen, Germany
Ownership Family-owned
Product families Solenoid valves, angle seat process valves, positioners, flow meters, mass flow controllers

Bürkert types listed on this page

Two types are listed. Type 6026 is a direct-acting 2/2-way plunger solenoid valve, with a stainless steel bellows that separates the medium from the coil, and as a direct-acting valve it switches without needing a pressure difference. Type 8681 is the Bürkert control head that mounts on top of hygienic process valves to pilot the actuator and report valve position to the control system. Control heads of this kind are common in food, beverage and pharmaceutical plants in the GCC.

Ordering Bürkert valves: what we need

The type number alone is not enough. Send the identification number from the label, or else the type with orifice, port connection, body and seal material, coil voltage and frequency, circuit function and pressure range. For a Type 8681 control head add the communication variant and the make and model of the process valve it sits on.

Facts checked against Bürkert's published company history, October 2026.

FAQ

Questions about the Bürkert 418762 Type 8025 Paddle Wheel Insertion

Answers from our engineering team on installation, compatibility and integration.

01What is Bürkert 418762?
It is a compact Type 8025 paddle-wheel insertion flowmeter, 12 to 36 V DC, short Hall sensor, 4 to 20 mA two-wire plus pulse output, female cable plug.
02Which pipes can the 8025 measure?
With a Type S020 insertion fitting it covers pipes from DN 20 to DN 400.
03What accuracy does 418762 reach?
The datasheet gives plus or minus 1 percent of reading with teach-in or plus or minus 2.5 percent with the standard K factor.
04Does the meter need a fitting?
Yes. It screws into a Bürkert Type S020 insertion fitting with a G 2 process connection, which is selected separately.
05What is the pressure limit?
The datasheet gives a maximum fluid pressure of PN 10, subject to the fitting data.