Brake and door systems on trains depend on dry compressed air, and the MICHELL Instruments SF72 Rail monitors it. It is a compact 316 stainless steel dew-point transmitter that measures minus 60 to plus 60 degrees Celsius, with accuracy of plus or minus 2 C, in a body pressure rated to 450 bar. The datasheet describes a 10-year field-proven stainless body and glass-to-metal seal for environments with constant vibration, and it holds shock and vibration and EMC certifications to rail standards. Seven Star LLC is an independent supplier serving Oman and the GCC.

Features of the MICHELL Instruments SF72 Rail

  • Dew-point range of -60 to +60 C, with plus or minus 2 C accuracy and plus or minus 0.2 C repeatability.
  • Rail certifications: shock and vibration to IEC 61373:1999-01 (EN 50155) and RFI/EMC emissions and immunity to EN 50121-3-2:2016.
  • M12, 4-pin (A coded) electrical connector.
  • Two-wire 4-20 mA current source output with digital diagnostic communications over two-wire RS485 Modbus RTU.
  • Traceable 8-point calibration certificate.
  • CE and UKCA compliant.

MICHELL Instruments SF72 Rail specifications

Measurement range -60 to +60 C (-76 to +140 F) dew point
Accuracy / repeatability Plus or minus 2 C dew point / plus or minus 0.2 C
Long-term stability Less than 1 percent per year at reference conditions
Calibration Traceable 8-point certificate
Output 4-20 mA, 2-wire current source, standard scaling -60 to +60 C
Supply voltage 12 to 28 V DC
Load resistance Maximum 250 ohm at 12 V; 500 ohm at 24 V
Start-up temperature Ambient -40 to +50 C; gas -40 to +70 C
Operating temperature Ambient -40 to +50 C; gas -40 to +60 C
Storage temperature -40 to +85 C
Operating pressure 45 MPa (450 barg / 6526 psig) maximum; over-pressure 90 MPa
Flow rate 1 to 5 Nl/min in a standard sample block; 0 to 10 m/s direct insertion
Housing 316 stainless steel, IP66
Dimensions Length 119 mm including HDPE filter, diameter 27 mm
Filter HDPE guard, less than 10 micron
Process connection G1/2 inch BSP, 316 stainless steel
Weight 150 g (5.29 oz)
Diagnostics 23 mA sensor fault; 4 mA under-range; 20 mA over-range

Design for key rail measuring points

The datasheet focuses on the key minus 50 to plus 10 degrees Celsius dew-point range where response speed, reliability and long-term stability matter in a control process. The polymer-based sensor is calibrated on a high-volume traceable system, supporting OEM quantities, and the stainless body with glass-to-metal seal suits constant vibration.

Applications in Oman and the GCC

Rolling stock, metro and light rail fleets, and the compressed air systems of depots and wayside workshops need dry air to avoid freezing and corrosion. Regional metro networks and industrial rail users can fit the transmitter to an air dryer outlet, while the wide 45 MPa rating also allows use in high-pressure gas systems.

How SF72 Rail differs from SF52 and SF82

  • SF72 Rail reads -60 to +60 C dew point; SF52 reads -40 to +60 C.
  • SF72 Rail is a two wire 4-20 mA transmitter with an M12 connector and a 316 stainless body; SF52 is a nickel-coated brass, three-wire design with a 2 m cable.
  • SF72 Rail withstands 45 MPa with 90 MPa over-pressure; SF52 is limited to 2 MPa.
  • SF72 Rail carries IEC 61373 shock and vibration and EN 50121-3-2 EMC approvals for rail use.

Why dew point matters on the MICHELL Instruments SF72 Rail application

Air that is not dry enough forms condensate in brake pipes, valve blocks and door actuators, which can freeze in cold climates or corrode in humid ones. Measuring dew point at the dryer outlet gives an early warning that desiccant is exhausted or a refrigerated dryer is failing, long before water reaches downstream parts. A transmitter with a recessed polymer sensor behind a sub-10 micron guard gives a stable signal even when the gas carries fine particulates.

Output and diagnostics

The 4-20 mA output is scaled to the full minus 60 to plus 60 C range as standard, and other scaling can be requested. The loop supports up to 250 ohm of load at 12 V and 500 ohm at 24 V, so ordinary train control inputs can be used. Under-range and over-range conditions drive the output to 4 mA and 20 mA, and a sensor fault drives it to 23 mA, which lets a controller separate a real dry condition from a failed sensor. The RS485 Modbus RTU channel, reached with the optional communication kit, gives access to diagnostic data.

Accessories and installation

Accessories listed in the datasheet include EA2-HDPE guards in packs of 10, an SB-12 G1/2 inch 316 stainless sample block with 1/8 inch NPT ports, replacement labels, an SF72-CK communication kit, an EN 10204 3.1 material certificate, bonded seal packs and recalibration service. Fit the transmitter in a sample block at 1 to 5 Nl/min or insert it directly into a gas stream up to 10 m/s, wire the loop on pins 3 and 4 of the M12 connector (pin 3 4-20 mA, pin 4 supply positive), and scale the input at the control system.

Maintenance

Replace the HDPE filter when contaminated, check the bonded seal on the process connection when the unit is removed, and recalibrate on the schedule your maintenance plan requires, as long-term stability is stated as less than 1 percent per year.

Related products and ordering notes

State the connection, scaling range and accessories needed (sample block, communication kit, material certificate) when requesting SF72 Rail.

Related items you may also need: Michell EA-XP Easidew PRO XP Explosion-Proof Dew-Point Transmitter | Michell S8000 Remote S8K421 Chilled Mirror Hygrometer | Michell QMA601 Quartz Crystal Microbalance Moisture Analyzer | All MICHELL Instruments products.

If the MICHELL Instruments SF72 Rail is replacing an installed unit, record the existing tag number, the process service and the supply conditions before requesting a quotation. These details make it easier to cross-check the configuration against the official documentation and to flag anything that should be verified with the manufacturer before the part is installed.

Configuring the MICHELL Instruments SF72 Rail for your process

The MICHELL Instruments SF72 Rail is a model family that Michell builds to a configuration, so the orderable unit is fixed by the options below and not by the model name alone.

  • Measuring range and the gas or sample the MICHELL Instruments SF72 Rail will analyse.
  • Output signals and communication needed by your control system, for example 4-20 mA, relays or a digital protocol.
  • Supply voltage and the mounting style required on site.
  • Hazardous area classification of the installation location, if any.
  • Sample handling and process connection details, including pressure, temperature and any sampling system or accessories.

Send these details, or the full code from the nameplate of an existing unit, and the quotation will confirm the exact configuration before order.

Documents and quotation

The datasheet for the SF72 Rail is attached on this page. To check availability, send an RFQ to Seven Star LLC with the part number SF72 Rail, the quantity and your destination in Oman or the GCC.

Other Models in the SF Range

Seven Star LLC supplies models from the SF range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
MICHELL Instruments SF52 Dew-Point Transmitter for DryersHumidity & Dew Point InstrumentsView details
MICHELL Instruments SF72 Rail Dew-Point Transmitter for RailHumidity & Dew Point InstrumentsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet MICHELL Instruments SF72 Rail Dew-Point Transmitter for Rail Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).

Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.

MICHELL Instruments company profile

Founded 1974, Cambridge, England, by Andrew Michell
Headquarters Ely, Cambridgeshire, United Kingdom, since 2007
Ownership Process Sensing Technologies (PST)
Technology Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell)
Product families Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers

Milestones

  • 1974: Andrew Michell founds Michell Instruments in Cambridge.
  • 2007: The company moves to Ely, Cambridgeshire.
  • 2024: Michell marks 50 years, now as part of PST.

Michell product families on this page

The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.

Where Michell analyzers are used

Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.

MICHELL Instruments products we list

Family Examples
Gas Analyzer Systems Easidew PRO I.S. Intrinsically Safe Mois…, Michell CD2-WDC-002 Water Dew-Point Sens…, Michell Condumax II Hydrocarbon Dew-Poin…, Easidew EA2 Dew Point Transmitter, Michell OptiPEAK TDL600 Moisture in Natu…, Michell Promet EExd Process Moisture Ana…, Michell S8000 Precision Chilled Mirror H…
Gas Analyzer Accessories MICHELL CD2-SX-WDC-002 Water Dew-Point S…, Michell Ceramic Impedance Moisture Senso…, Michell Condumax II CD2-SCR-002 Hydrocar…

Ordering Michell parts: what we need

For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.

Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.

FAQ

Questions about the MICHELL Instruments SF72 Rail Dew-Point Transmitter

Answers from our engineering team on installation, compatibility and integration.

01What range does the SF72 Rail cover?
It measures -60 to +60 C dew point with plus or minus 2 C accuracy, plus or minus 0.2 C repeatability and stability under 1 percent per year.
02Which rail certifications does the SF72 Rail hold?
It is certified for shock and vibration to IEC 61373:1999-01 (EN 50155) and for RFI/EMC emissions and immunity to EN 50121-3-2:2016.
03What output does the SF72 Rail have?
It has a two-wire 4-20 mA current source output with 12 to 28 V DC supply and RS485 Modbus RTU diagnostic communications through an M12 4-pin connector.
04What pressure rating does the SF72 Rail have?
The transmitter operates up to 45 MPa (450 barg, 6526 psig) with an over-pressure rating of 90 MPa, in a 316 stainless steel IP66 housing.
05What accessories are available for the SF72 Rail?
Accessories include HDPE guards, an SB-12 sample block, a communication kit SF72-CK, EN 10204 3.1 material certificate, bonded seals and recalibration service.