MICHELL Instruments XZR500 Combustion Control Oxygen Analyzer

Description

Overview

Boilers, incinerators and furnaces waste fuel when they run with too much air, and the MICHELL Instruments XZR500 exists to expose that waste. It is a close-coupled extractive zirconium oxide analyzer that reports 0.01 to 25 percent oxygen in flue gas and can work with sample temperatures reaching 1400 degrees Celsius when a ceramic probe is fitted. The sensor sits in an oven inside the sensor head, bolted to the stack, rather than inside the probe itself. Seven Star LLC is an independent supplier serving Oman and the GCC.

What sets the MICHELL Instruments XZR500 apart

The sensing element uses the manufacturer’s Metallic Sealed Reference Sensor, abbreviated MSRS. It holds a known quantity of oxygen inside the sensor, so there is no supply of reference gas or fresh ambient air to maintain. The datasheet says the technology was developed from a sensor first designed for volcano environments, and it describes the MSRS as resistant to pollution and virtually drift-free, which cuts the number of calibrations needed at points that are awkward to reach.

Sample is drawn into the sensor by a Pitot effect created in the probe and vented back into the stack, so most installations need no aspirator or eductor air. Only very dusty duty, defined in the datasheet as sample containing more than 250 mg per cubic metre of particulates, requires the back-flush option. Because the cell is not in the gas stream, the chance of thermal shock to the sensor is described as virtually nil.

MICHELL Instruments XZR500 technical specifications

Sensor Zirconium oxide with metallic sealed reference and K type thermocouple (MSRS)
Measurement range 0.01 to 25 percent oxygen
Accuracy Better than plus or minus 2 percent of reading range
Response time (T90) 20 seconds
Repeatability Plus or minus 0.1 percent
Drift Less than 1 percent per month
Linearity Better than plus or minus 1 percent
Sample flow Flue gas at 0.5 m/s (17.65 ft/s) minimum
Sample temperature Up to 1400 C depending on probe material
Sensor temperature 700 C (1292 F)
Probe lengths 0.4, 0.6 and 0.9 m
Probe materials 316L stainless steel to 700 C; Inconel to 1000 C; HR160 600-1000 C; C2000 to 600 C; Halar coated to 120 C; ceramic to 1400 C; silicon carbide 1300 C
Output One 0/4 to 20 mA linear, galvanically isolated; second output optional; load over 1000 ohm
Alarms 2 user adjustable alarms and 1 fault alarm
Display resolution 0.1 percent standard
Power supply 110 V (100 to 120) 50-60 Hz or 220 V (190 to 240) 50 Hz
Ambient temperature / humidity 0 to +55 C; 5 to 90 percent rh without condensation
Control unit 300 x 300 x 200 mm, 7 kg, IP52
Sensor head 290 x 135 x 650 mm, 3.5 kg, IP53
Probe weight 1.5 kg to 4.5 kg
Probe flange PN6 DN15, four 11 mm holes on a 55 mm circle

Typical applications in Oman and the GCC

The manufacturer lists boilers, crematoria, waste and industrial incinerators, coal-fired power plants, annealing and galvanizing furnaces and auxiliary marine boilers. For Gulf plants this covers steam and hot-water boilers at utilities and desalination facilities, heaters in oil and gas processing, medical and municipal waste incineration, and ship or port services boilers. Control of excess air in these systems lowers fuel use and flue gas losses while keeping carbon monoxide in check.

Selection notes: how XZR500 differs from XZR250 and XZR200

  • XZR500 reads down to 0.01 percent O2; XZR250 starts at 0.1 percent and XZR200 offers 0 to 25 or 0 to 100 percent.
  • XZR500 offers three probe lengths in several alloys, ceramic and silicon carbide up to 1400 C; XZR250 has a single 435 mm stainless probe to 700 C; XZR200 has 210 or 400 mm probes to 400 C.
  • XZR500 uses a separate wall-mounted control unit on 110 or 220 V mains; XZR250 and XZR200 are single-housing 24 V DC instruments.
  • Only the XZR500 offers the back-flush option for heavy dust loading.

Specify the MICHELL Instruments XZR500 for hot, dusty, corrosive or very high temperature flue gas, or whenever a remote control unit is preferred.

Installation and commissioning

The datasheet describes a weld-on mounting plate or tubular counter-flange fitted to the stack, with the probe head kept vertical. Probe tubes should slope no more than 5 degrees so condensate can drain into the flue. Place the probe so that gas enters through the orifice near the tip of the outer tube and leaves at the bevelled edge of the inner tube, facing opposite directions. Fit all gaskets so there is no air leak between probe and outside air. The control unit goes in a weather-proof wall cabinet and connects through the supplied 6 m interconnecting cable, with the special cable above the probe axis. A single calibration gas serves most applications, and auto-calibration is optional.

Maintenance

Routine work is simple: operators use three buttons to alter parameters and read the self-diagnostics on the display. In dusty service the blow-back function clears the probe of debris. If the plant has a long shutdown, inspect the probe for condensed particles before restart. The modular build lets a probe be replaced independently of the sensor head.

Related products and ordering notes

For a quotation, state the probe length (0.4, 0.6 or 0.9 m), the probe material and the temperature of the stack, the mains voltage, and whether back-flush or auto-calibration options are wanted. Other Michell oxygen and moisture analyzers are listed on this site.

Related items you may also need: Michell S8000 Remote S8K421 Chilled Mirror Hygrometer | Michell XP-DIS-RK Easidew PRO XP Replacement Display Module Kit | Michell SF82-TX SF82 Industrial Dew-Point Transmitter | All MICHELL Instruments products.

If the MICHELL Instruments XZR500 is replacing an installed unit, record the existing tag number, the process service and the supply conditions before requesting a quotation. These details make it easier to cross-check the configuration against the official documentation and to flag anything that should be verified with the manufacturer before the part is installed.

Details needed to quote the MICHELL Instruments XZR500

The MICHELL Instruments XZR500 is a model family that Michell builds to a configuration, so the orderable unit is fixed by the options below and not by the model name alone.

  • Measuring range and the gas or sample the MICHELL Instruments XZR500 will analyse.
  • Output signals and communication needed by your control system, for example 4-20 mA, relays or a digital protocol.
  • Supply voltage and the mounting style required on site.
  • Hazardous area classification of the installation location, if any.
  • Sample handling and process connection details, including pressure, temperature and any sampling system or accessories.

Send these details, or the full code from the nameplate of an existing unit, and the quotation will confirm the exact configuration before order.

Documents and quotation

The manufacturer datasheet for the XZR500 is attached to this page. To request availability and lead time, send an RFQ to Seven Star LLC with the part number XZR500, the quantity and the probe configuration, together with your delivery point in Oman or the GCC.

Other Models in the XZR Range

Seven Star LLC supplies models from the XZR range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
MICHELL Instruments XZR250 Zirconia Oxygen Analyzer 0.1-25% O2Gas Analyzer SystemsView details
MICHELL Instruments XZR500 Combustion Control Oxygen AnalyzerGas Analyzer SystemsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet MICHELL Instruments XZR500 Combustion Control Oxygen Analyzer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).

Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.

MICHELL Instruments company profile

Founded 1974, Cambridge, England, by Andrew Michell
Headquarters Ely, Cambridgeshire, United Kingdom, since 2007
Ownership Process Sensing Technologies (PST)
Technology Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell)
Product families Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers

Milestones

  • 1974: Andrew Michell founds Michell Instruments in Cambridge.
  • 2007: The company moves to Ely, Cambridgeshire.
  • 2024: Michell marks 50 years, now as part of PST.

Michell product families on this page

The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.

Where Michell analyzers are used

Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.

MICHELL Instruments products we list

Family Examples
Gas Analyzer Systems Easidew PRO I.S. Intrinsically Safe Mois…, Michell CD2-WDC-002 Water Dew-Point Sens…, Michell Condumax II Hydrocarbon Dew-Poin…, Easidew EA2 Dew Point Transmitter, Michell OptiPEAK TDL600 Moisture in Natu…, Michell Promet EExd Process Moisture Ana…, Michell S8000 Precision Chilled Mirror H…
Gas Analyzer Accessories MICHELL CD2-SX-WDC-002 Water Dew-Point S…, Michell Ceramic Impedance Moisture Senso…, Michell Condumax II CD2-SCR-002 Hydrocar…

Ordering Michell parts: what we need

For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.

Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.

FAQ

Questions about the MICHELL Instruments XZR500 Combustion Control

Answers from our engineering team on installation, compatibility and integration.

01What range does the XZR500 measure?
The XZR500 measures 0.01 to 25 percent oxygen with response time (T90) of 20 seconds, repeatability of plus or minus 0.1 percent and drift below 1 percent per month.
02Does the XZR500 need reference air or an aspirator?
No for most applications. The MSRS holds an internal oxygen reference and sample is drawn by a Pitot effect; only dusty gas above 250 mg per cubic metre needs the back-flush option.
03Which probe lengths and materials are available for the XZR500?
Probes come in 0.4, 0.6 and 0.9 m lengths, in 316L stainless steel, Inconel, HR160, C2000, Halar coated, ceramic and silicon carbide, for sample temperatures up to 1400 C.
04What power supply does the XZR500 use?
The control unit runs from 110 V (100 to 120 V) at 50 to 60 Hz or from 220 V (190 to 240 V) at 50 Hz and provides one isolated 0/4 to 20 mA output.
05How is the XZR500 calibrated?
The metallic sealed reference allows a single calibration gas to be used for most applications, and auto-calibration is available as an option.