Brand:

ifm PN5001 Pressure Switch with Display, 0 to 250 bar, G 1/4

Description

PN5001: a plain 250 bar switch from the PN5 line

The ifm PN5001 strips pressure sensing back to a switch: one switching output, no analogue and no IO-Link, on a 0 to 250 bar range. The order description is PN-250-SBR14-HFPKG/US/ /V. The datasheet lists it as an archive entry with the PN7071 as alternative article. For hydraulic pumps, press circuits and gas storage where the control cabinet only needs a contact, the lack of extra functions is an advantage.

Concise feature list

  • Switching output only, configured by the three-LED operating panel.
  • Pressure rating 400 bar, minimum burst pressure 850 bar.
  • Ingress protection IP 67, higher than the IP 65 of the PN7 and PN2024 devices.
  • Ambient range minus 20 to 80 degC and medium temperature minus 25 to 80 degC.
  • Ceramic cell with FKM sealing in a stainless steel G 1/4 internal thread.

PN5001 parameter list

Product type Pressure sensor with display, one switching output
Measuring range 0 to 250 bar (0 to 3625 psi, 0 to 25 MPa)
Process connection G 1/4 internal thread
Media / temperature Liquids and gases, minus 25 to 80 degC
Pressure rating 400 bar (5800 psi)
Minimum burst pressure 850 bar (12300 psi)
Operating voltage 18 to 36 V DC (SELV/PELV)
Output 1 switching output
Repeatability under plus/minus 0.1 percent of span
Ambient temperature minus 20 to 80 degC
Protection IP 67
Dimensions / weight Diameter 34 mm, length 91.5 mm / 261.6 g
Housing materials Stainless steel 304 and 316L, PC, PBT, PEI, FKM
Wetted parts Stainless steel 303 (1.4305), ceramics, FKM
Pressure cycles At least 100 million
Display 3 green LEDs

Read as running text, the manufacturer datasheet of the PN5001 states the following. Product type: Pressure sensor with display, one switching output. Measuring range: 0 to 250 bar (0 to 3625 psi, 0 to 25 MPa). Process connection: G 1/4 internal thread. Media / temperature: Liquids and gases, minus 25 to 80 degC. Pressure rating: 400 bar (5800 psi). Minimum burst pressure: 850 bar (12300 psi). Operating voltage: 18 to 36 V DC (SELV/PELV). Output: 1 switching output. Repeatability: under plus/minus 0.1 percent of span. Ambient temperature: minus 20 to 80 degC. Protection: IP 67. Dimensions / weight: Diameter 34 mm, length 91.5 mm / 261.6 g. Housing materials: Stainless steel 304 and 316L, PC, PBT, PEI, FKM. Wetted parts: Stainless steel 303 (1.4305), ceramics, FKM. Pressure cycles: At least 100 million. Display: 3 green LEDs.

At 250 bar the energy stored in a hydraulic circuit is large, so the margins in the datasheet matter. The 400 bar pressure rating covers pressure peaks 60 percent above the measuring range end, and the 850 bar minimum burst figure is more than three times the range. Switching sensors in this class are usually adjusted once and left, and the three-LED display with keypad lets a technician change the set point without a laptop. Stable temperature behaviour, expressed as repeatability under plus/minus 0.1 percent of span for temperature swings below 10 K, keeps the switching point from wandering when the hydraulic oil warms up during a shift.

Where it works

Pressure switching at this range fits hydraulic clamping, accumulator pre-charge supervision, high-pressure washing equipment and gas cylinder manifolds. In Oman the typical buyers are maintenance contractors replacing an installed PN5001 on pumps, test benches and presses where the existing wiring is a simple two or three wire switching connection. For new designs the alternative named by the manufacturer should be compared.

How PN5001 differs from other PN5 and PN7 sensors

Against the PN5004 (same single output, minus 1 to 10 bar, 75 bar rating, IP 65) this device is the high-pressure choice with 400 bar rating and IP 67. Against the PN2271 (0 to 250 bar, 500 bar rating, 1/4 NPT, analogue plus IO-Link) it uses a G 1/4 thread, a ceramic cell and has no analogue output. The weight is 261.6 g and the supply range is 18 to 36 V DC.

Installation hints

Specify a sealing washer to suit G 1/4 sealing faces, tighten moderately and avoid side load by the hose. Teach the switching and reset points at working pressure and run a trial with the pump to confirm the hysteresis.

Service

Check for oil film on the display window, which could hide the LEDs, and test the switch by raising the pressure through a calibrated hand pump once a year. Replace the sensor after repeated overpressure above 400 bar.

RFQ

List PN5001 and the quantity. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Delivery to Sites in Oman and the GCC

Delivery of the ifm PN5001 is arranged to suit the site, whether that is a plant in Sohar or Duqm, an oilfield location in the interior, or a project elsewhere in the GCC. Tell us the delivery point, any site access or gate-pass requirements, and the person who will receive the goods. Goods are packed to protect sensitive pressure transmitters equipment during road or air transport, and shipping details are shared once the order is dispatched so that your stores team can plan receipt and inspection.

Selection Notes for the ifm PN5001

When comparing the ifm PN5001 with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the ifm pressure transmitters range and confirm the correct order code before you commit.

Frequently asked questions about the PN5001

  • What does the ifm PN5001 do? It monitors pressure in the range 0 to 250 bar and provides one switching output, with a local three-LED display.
  • What is the pressure rating of the PN5001? The datasheet states a rating of 400 bar and a minimum burst pressure of 850 bar, with IP 67 protection.
  • Does the PN5001 have IO-Link or an analogue output? No. Its output is a single switching output; the PN2271 provides analogue and IO-Link at the same 250 bar range.
  • What alternative is listed for the PN5001? The datasheet shows an archive entry, no longer available, and names the PN7071 as alternative article.
  • How can I request a quotation for the PN5001? Send part number PN5001, the quantity and your delivery location via the RFQ form to Seven Star LLC.

Documents and quotation

Download the datasheet for the PN5001 from this page to confirm the figures before you buy. Then send your RFQ with the exact part number PN5001, the quantity you need and the site where it will be used, and we will answer with availability and a quotation.

Other Models in the PN5 Range

Seven Star LLC supplies models from the PN5 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
ifm PN5001 Pressure Switch with Display, 0 to 250 bar, G 1/4Pressure TransmittersYou are viewing this model
ifm PN5004 Pressure Switch with Display, -1 to 10 bar, G 1/4Pressure TransmittersView details
Datasheets & Documents
  • PDF Datasheet ifm PN5001 Pressure Switch with Display, 0 to 250 bar, G 1/4 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ifm is a German family-owned maker of sensors and automation products, founded in Essen in October 1969 by Robert Buck and Gerd Marhofer. Its first products were inductive proximity sensors sold under the efector name. ifm is still headquartered in Essen, and the founders' sons, Martin Buck and Michael Marhofer, have led it since 2001.

Seven Star LLC lists ifm position, distance and pressure sensors and supplies them by exact article number to plants and machine builders in Oman and the wider Gulf region.

ifm company profile

Founded 1969, Essen, Germany
Founders Robert Buck and Gerd Marhofer
Headquarters Essen, Germany
Ownership Family-owned
Product families Inductive and capacitive proximity sensors, PN pressure sensors, O1D laser distance sensors, flow and level sensors, IO-Link masters

Milestones

  • 1969: ifm is founded in Essen.
  • 2001: The founders' sons take over management.

ifm sensors listed on this page

ifm identifies every device with a short article number, and that number is what we order against. Three are listed here:

  • O1D100: laser distance sensor for position and distance measurement
  • PN7093: pressure sensor with local display
  • NG5021: inductive proximity sensor with NAMUR output

Other ifm inductive sensors, pressure sensors and connection cables can be quoted on request when you send the article number.

ifm products we list

Family Examples
Inductive Proximity Sensors NG5021 Inductive NAMUR Proximity Sensor
Laser Distance, LiDAR & Radar Sensors O1D100 Laser Distance Sensor
Pressure Instrumentation PN7093 Pressure Sensor with Display

Ordering ifm sensors: what we need

Send the six-character article number printed on the housing (two letters and four digits, or similar). If the label is worn, a photo plus the thread size, sensing range, output type and connector style is enough for us to check the part against ifm documentation. For NAMUR sensors, tell us which isolating amplifier is in the loop. Buyers in the GCC who need a successor for a discontinued article can send the old number and we will check the replacement the manufacturer names.

Facts checked against ifm's own 50-year chronicle (ifm.com), October 2026.

FAQ

Questions about the ifm PN5001 Pressure Switch with Display, 0 to 250

Answers from our engineering team on installation, compatibility and integration.

01What does the ifm PN5001 do?
It monitors pressure in the range 0 to 250 bar and provides one switching output, with a local three-LED display.
02What is the pressure rating of the PN5001?
The datasheet states a rating of 400 bar and a minimum burst pressure of 850 bar, with IP 67 protection.
03Does the PN5001 have IO-Link or an analogue output?
No. Its output is a single switching output; the PN2271 provides analogue and IO-Link at the same 250 bar range.
04What alternative is listed for the PN5001?
The datasheet shows an archive entry, no longer available, and names the PN7071 as alternative article.
05How can I request a quotation for the PN5001?
Send part number PN5001, the quantity and your delivery location via the RFQ form to Seven Star LLC.