Brand: Panametrics
Panametrics SIM-12H Heated Chilled Mirror Dew Point Sensor
Description
SIM-12H heated chilled mirror sensor for high dew points
The Panametrics SIM-12H is a thermostatically controlled, heated, two-stage chilled mirror sensor built to measure dew points up to 85 C. A chilled mirror hygrometer is a primary humidity measurement: the sensor cools a mirror until dew just forms and reports the mirror temperature. When the dew point is above ambient temperature, every part that touches the sample has to sit above the dew point, otherwise water condenses in the tubing and the reading is wrong. The SIM-12H therefore has its own heater with thermostatic set points at 25, 40, 55, 70, 85 and 100 C, and a cooling depression of 85 C at a 75 C body temperature. It is normally driven by a Panametrics Optica chilled mirror analyzer, and can also be bought as the heart of the turnkey HSS-12 heated sampling system.
SIM-12H capabilities
- Typical measurement range of minus 10 to plus 75 C dew or frost point in air at 75 C body temperature, 25 C ambient and atmospheric pressure, equivalent to 1 to 100 percent RH.
- Two-stage thermoelectric cooler with negligible hysteresis.
- Dew point accuracy of 0.2 C standard, 0.15 C with the enhanced accuracy option.
- Repeatability of 0.05 C and sensitivity better than 0.03 C.
- Field-replaceable rhodium-plated copper mirror, or a more robust solid platinum mirror as an option.
- Vapor barrier upgradeable from standard Mylar to stainless steel.
SIM-12H specifications
| Parameter | SIM-12H |
|---|---|
| Sensing element | 4-wire 1/3 Class A DIN 43760 PRT, 100 ohm at 0 C |
| Sample flow | 0.5 to 2.5 SCFH (0.25 to 1.25 L/min) |
| Operating temperature | -15 to 100 C (5 to 212 F) |
| Sample pressure | -3 to 50 psig (0.8 to 4.5 bar) |
| Power | 100/115/230 VAC, 50 to 60 Hz, 75 W |
| Body and wetted materials | Cast aluminum with 314 stainless flow cell; 302 and 316 stainless, silicone O-ring, BK-7 glass, rhodium or platinum mirror |
| Connectors | MS-style multipin connector mating with Optica cable; IEC power receptacle |
| Inlet and outlet | 1/4 in compression fittings |
| Weight | 7 lb (3.2 kg) net |
| Accessory codes | P platinum mirror; X enhanced accuracy 0.15 C; S stainless steel vapor barrier |
What comes with the HSS-12 turnkey system
The HSS-12 assembles the sensor with a heated filter, flow meter and sample line on a mounting plate of 23 in by 13 in (584 by 330 mm). The SIM-HFT heated filter module passes the gas first through a 90 micron prefilter and then a 15 micron final filter, both of sintered stainless steel, all kept at a constant 105 C and rated to 50 psig at 100 W. The SIM-HFM heated valve and flowmeter, mounted downstream of the sensor, gives a front panel metering valve over 0 to 2 SCFH at 105 C. The SIM-HSL heated sample line is self-regulating at 125 C in 15 ft (4.6 m) lengths for 115 VAC or 35 ft (10.7 m) lengths for 230 VAC, with 250 W rating and PTFE construction. The mounting plate SIM-MPL accepts the sensor, filter and flowmeter and is wired and plumbed at the factory.
How SIM-12H differs from unheated chilled mirror sensors
Unheated sensors are suitable when the dew point is below ambient. The SIM-12H adds heater control and a cooling depression of 85 C at 75 C body temperature, so a dew point of 75 C can be measured when the body is held at 75 C. A body temperature set below the dew point of the gas will cause condensation, so the set point must be chosen above the highest dew point expected. Standard sensors cannot do this and need to be mounted outside the high humidity zone with an unheated sample line.
Applications in Oman and GCC plants
Hot, humid process gases such as dryer exhaust, combustion and flue gas samples, furnace and kiln atmospheres and environmental chamber air with a dew point above 40 C need heated sampling. Chilled mirror sensors are also used as primary references for calibrating other hygrometers, and the datasheet notes that with an Optica analyzer the system gives precise primary humidity measurement. Gulf climate test chambers and humid industrial processes are plausible users.
It is worth working through the arithmetic of heated sampling. The sensor body is controlled in steps from 25 to 100 C, and every component the sample touches should be hotter than the dew point; the heated filter and flow valve run at a constant 105 C and the heated line at 125 C, so a sample with a dew point of up to about 85 C stays fully in the vapor phase until it reaches the cooled mirror. The mirror is then cooled by the two-stage thermoelectric module until a dew layer forms, the control loop holds that layer constant and the platinum resistance thermometer in the mirror reports its temperature, which is the dew point. Because the principle depends on the physical state of the water and not on a calibration of an electrical property, the measurement is regarded as primary, and the repeatability of 0.05 C and negligible hysteresis make it suitable for reference duty. Contamination of the mirror by oils or salts would bias the reading, which is why the pre-filter and final filter in the heated module matter.
Installation and maintenance
Mount the assembly where the heated components can reach their set temperature, keep the sample line heated end to end, pick the sensor body temperature above the dew point, and keep flow in the 0.5 to 2.5 SCFH window. Clean the mirror according to the Optica manual and replace the filter elements when they clog. The filters are easily removable for cleaning or replacement.
Supplier note
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Items such as the heated filter, heated sample line or replacement mirrors can be quoted on request.
Documents and quotation
The manufacturer datasheet for SIM-12H and HSS-12 is provided. Send an RFQ stating SIM-12H or HSS-12, mirror type, accuracy option, vapor barrier, mains voltage and quantity.
Datasheets & Documents
- Datasheet Panametrics SIM-12H Heated Chilled Mirror Dew Point Sensor Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Panametrics is an American maker of ultrasonic flowmeters and moisture, oxygen and gas analysers. It was founded in 1960 and was based in Waltham, Massachusetts, when GE bought it in 2002. It later became a Baker Hughes business, and since 1 January 2026 it has belonged to Crane Company. Its long-running site in Shannon, Ireland, opened in 1973.
Seven Star LLC lists Panametrics flowmeters and analyzers for buyers in Oman: DigitalFlow gas and flare meters, clamp-on and portable liquid meters, and trace moisture analyzers for natural gas and process gases. We are an independent supplier, so each inquiry is checked against the manufacturer's order string before a quotation goes out.
Panametrics company profile
| Founded | 1960, Massachusetts, USA |
|---|---|
| Main sites | Billerica, Massachusetts, and Shannon, Ireland (since 1973) |
| Ownership | Crane Company since 1 January 2026; previously GE (from 2002) and Baker Hughes |
| Key technology | Transit-time ultrasonic flow measurement and aluminium oxide moisture sensing |
| Product families | TransPort PT900 portable and DigitalFlow fixed ultrasonic flowmeters for liquid, gas and flare gas, aluminium oxide moisture probes and hygrometers, Aurora laser moisture analysers, XMO2 oxygen and XMTC thermal conductivity transmitters |
Milestones
- 1960: Panametrics is founded.
- 1973: The Shannon, Ireland, site is established.
- 2002: GE acquires Panametrics.
- 2026: Crane Company completes its purchase of Baker Hughes' Precision Sensors & Instrumentation, including Panametrics.
Panametrics product families on this page
The listed items follow the manufacturer's own grouping:
- Gas and flare flow: DigitalFlow GF868 flare gas meter, GM868 and XGM868i gas flow transmitters
- Liquid flow: XMT1000 transmitter, AT600 AquaTrans clamp-on meter, TransPort PT900 portable meter
- Moisture: moisture.IQ multichannel analyzer, HygroPro II aluminum oxide transmitter, Aurora TDLAS analyzer for natural gas
Older units may carry GE Panametrics or GE Sensing on the nameplate. They belong to the same product lines, and the model string is read the same way.
Where Panametrics flowmeters and moisture analyzers are used
Flare meters report flared volumes on production sites, refineries and LNG plants. Clamp-on and portable ultrasonic meters check water, hydrocarbon liquid and utility lines without cutting the pipe. Aluminum oxide and TDLAS moisture analyzers watch dehydration units, gas pipelines, hydrogen and industrial gas streams. The manufacturer also names chemical processing, energy and water and wastewater among its markets, which matches what GCC operators ask us for.
Panametrics products we list
Ordering Panametrics equipment: what we need
A Panametrics model is a long configuration string, and the transducers or probes are ordered separately. Please send the full model and serial number of the electronics, the transducer or moisture probe part number, pipe size, schedule and material, fluid, pressure and temperature, flow range, hazardous area approval and output or protocol. For a flare meter add the flare gas composition range and velocity range. For moisture, give the dew point range and whether sample system components are required.
Facts checked against GE's 2002 acquisition release, Crane Company's January 2026 completion release and Irish press, October 2026.
FAQ
Questions about the Panametrics SIM-12H Heated Chilled Mirror Dew Point
Answers from our engineering team on installation, compatibility and integration.
01What dew point range does the SIM-12H cover?
Typically minus 10 to plus 75 C dew or frost point in air at 75 C body temperature, equal to 1 to 100 percent RH at 25 C ambient.
02How accurate is the SIM-12H?
Dew point accuracy is 0.2 C as standard and 0.15 C with the enhanced accuracy option, with repeatability of 0.05 C.
03What does the HSS-12 include besides the SIM-12H sensor?
A SIM-HFT heated filter, a SIM-HFM heated valve and flowmeter and a SIM-HSL heated sample line on a SIM-MPL mounting plate.
04Which analyzer does the SIM-12H connect to?
It uses an MS-style connector that mates with the Optica cable and is intended for use with the Optica chilled mirror analyzer.
05What mirror materials are available for the SIM-12H?
Rhodium-plated copper is standard and field replaceable, while solid platinum is an optional more robust mirror.