Brand:

Magnetrol 004-5867-043 TG1 1 Inch Class 150 316 SS Flange

Description

Magnetrol 004-5867-043: 1 Inch Class 150 316 SS Flange

If the Magnetrol 004-5867-003 is the 3 inch flange of the Thermatel TG1 range, the Magnetrol 004-5867-043 is its smallest relative. It is a 1 inch, Class 150 raised face flange in 316/316L stainless steel, and it exists for instrument tees and small branch connections where a thread alone is not acceptable to the plant standard.

One oddity is worth noting: the number is not in sequence with the other 150 lbs stainless flanges. The 1 1/2 inch to 6 inch sizes run 004-5867-001 to 004-5867-005, while 1 inch sits at 043 with the other 1 inch items (042, 044, 050, 051 and so on). Anyone searching for the “next number” will therefore miss it, so quoting the exact digits matters.

It fits the 3/4 inch NPT-M sensor connection only. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Key features of 004-5867-043

  • Magnetrol 004-5867-043 is the smallest flange in the TG1 list: 1 inch, 150 lbs raised face, 316/316L stainless steel.
  • It is listed first in the 150 lbs group, ahead of the 1 1/2 inch size 004-5867-001.
  • Threads on to a 3/4 inch NPT-M sensor; the flange hub is therefore the same size as the thread class it adapts.
  • 316/316L matches the standard sensor body material, code A.
  • A compact flange for instrument stubs and small-bore lines.

Technical data for 004-5867-043

Parameter Value
Part number 004-5867-043
Part type Thread-on mounting flange for Thermatel TG1 sensor
Flange size 1 inch
Pressure class Class 150 (150 lbs), raised face, ASME B16.5
Flange material 316/316L stainless steel
Sensor thread it fits 3/4 inch NPT male process connection only
Sensor families (3/4 NPT code 110) TMA, TMB, TMC, TMD, TMH and TMM
Source document Bulletin BE 54-605 Thermatel TG1 installation and operating manual, model identification section 4

The sensors that receive this flange have their own limits, and those limits do not change because a flange is added. The table below lists the sensor data that the manual publishes for the 3/4 inch NPT versions.

Sensor type Maximum process pressure
TMA/TMB spherical tip, material A 41.4 bar (600 psi) at +40 C, 33.8 bar (490 psi) at +120 C
TMC/TMD twin tip, minimum insertion length 207 bar (3000 psi) at +40 C, 170 bar (2460 psi) at +120 C
TMC/TMD twin tip, longer than minimum 128 bar (1850 psi) at +40 C, 105 bar (1517 psi) at +120 C
TMH high temperature sensor 414 bar (6000 psi) at +40 C, 233 bar (3380 psi) at +450 C
Sensor diameter 22.9 mm (0.90 inch), TMH 21.9 mm (0.86 inch)
Sensor length range 5 to 330 cm (2 to 130 inch); TMH 5.5 to 91 cm

Where 004-5867-043 is used in oil and gas, utilities, water and manufacturing

A 1 inch flange is common on sample conditioning panels, analyser sample loops, lube-oil and seal-gas skids and small utility lines. In these places a TG1 proves minimum flow through a cooling jacket or a purge line. The stainless material suits instrument air, nitrogen and demineralised water.

Packaged equipment builders in the region often specify 1 inch Class 150 as the standard instrument nozzle, which is why the 004-5867-043 flange is a typical item when a skid receives a thermal dispersion switch after delivery.

How 004-5867-043 differs from other Thermatel TG1 flange variants

Flange 004-5867-043 Comparison
Size 1 inch; next up is 1 1/2 inch, 004-5867-001
Class 150 lbs RF; 300 lbs twin 004-5867-044, 600 lbs twin 004-5867-050
Material 316/316L; carbon steel twin 004-5867-041, Hastelloy C twin 004-5867-052
Sensor options TMA, TMB, TMC, TMD, TMH, TMM with 3/4 inch NPT
Minimum insertion NPT sensors from 5 cm (2 inch)

Within the 1 inch family, 004-5867-043 is the stainless Class 150 member. Its carbon steel twin is 004-5867-041 and its Hastelloy C twin is 004-5867-052, and the other classes 004-5867-044 and 004-5867-050 raise the rating while keeping the metal.

Selection and compatibility for 004-5867-043

  • Size: 1 inch is the smallest thread-on size, so the sensor tip must be short enough for the line, starting at 5 cm for NPT TMA/TMB.
  • Material: 316/316L, matching sensor code A.
  • Class: 150 lbs RF only; 300 lbs is 004-5867-044 and 600 lbs is 004-5867-050 in the same material.
  • Use the mini sensor TMM (1/2, 3/4 or 1 inch NPT, 16 mm diameter) in very small pipe.

Fitting 004-5867-043 to the sensor

Because the line is small, check that the sensor tip with its 22.9 mm diameter (TMA to TMD) leaves flow area; where the pipe is smaller than the sensor can serve the manual offers the low flow body TML sensor with 1/4 or 1/2 inch connections, and the mini sensor TMM at 16 mm diameter.

Align the cable entry and use the shielded 2-wire cable between sensor and DIN rail electronics, with a maximum length of 500 m.

Maintenance and inspection of 004-5867-043

Small flanges are more exposed to knocks and vibration on skids. Look for loosened studs and leaks at the gasket at each service round, and re-tighten in sequence. Keep an identified spare of 004-5867-043 in the skid spares box, since this flange is rarely stocked by general suppliers.

Documents and quotation

The manufacturer manual BE 54-605 that lists 004-5867-043 is supplied with this page as a datasheet download; it contains the flange table, the sensor ordering code and the pressure and temperature ratings quoted above. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. To request pricing and lead time, send an RFQ that gives the part number 004-5867-043, the quantity, the sensor model code and the delivery location in Oman or the GCC, and we will reply with availability.

Installation and Commissioning Planning

Planning ahead shortens downtime when a Magnetrol 004-5867-043 goes into service. Confirm the available mounting space, cable entry or process connection, and the tools and spare seals needed on the day. Keep the existing configuration or calibration data so the new unit can be set up to match, and check that loop drawings and the asset register are updated after the swap. If the installation has to fit a short shutdown window, tell us the date when you request a quotation so that delivery of the Magnetrol equipment can be planned around it.

Other Models in the Magnetrol Tg1 Flange Range

Seven Star LLC supplies models from the Magnetrol Tg1 Flange range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Magnetrol 004-5867-056 TG1 2 Inch Class 600 Hastelloy C FlangeThermal Mass Flow Meters & ControllersView details
Magnetrol 004-5867-029 TG1 4 Inch Class 300 Carbon Steel FlangeThermal Mass Flow Meters & ControllersView details
Magnetrol 004-5867-043 TG1 1 Inch Class 150 316 SS FlangeThermal Mass Flow Meters & ControllersYou are viewing this model
Magnetrol 004-5867-003 TG1 3 Inch Class 150 316 SS FlangeThermal Mass Flow Meters & ControllersView details
Datasheets & Documents
  • PDF Datasheet Magnetrol 004-5867-043 TG1 1 Inch Class 150 316 SS Flange Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.

Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.

Magnetrol company profile

Established 1932, USA; headquarters in Aurora, Illinois
Ownership Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group
Product families Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand)
Applications Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection

Milestones

  • 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
  • 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
  • 2021: AMETEK acquires Magnetrol on 29 March.

Magnetrol products we list

Model Principle Typical use
Eclipse 706 Guided wave radar Level and interface in separators, chambers and boiler drums, unaffected by changing density
Pulsar R80 80 GHz FMCW radar Narrow-beam non-contact level in tanks with internals and in solids
Pulsar R86 26 GHz radar Non-contact level in process and storage vessels
Pulsar R96 6 GHz radar Non-contact level where vapour, foam or condensation are present
E4 Modulevel Displacer Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units
Echotel 961/962 Ultrasonic gap switch High and low level alarms and pump protection
Thermatel TD1/TD2 Thermal dispersion switch Flow and no-flow detection and level switching for liquids and gases

Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.

Where Magnetrol instruments are used

In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.

Ordering Magnetrol instruments: what we need

Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.

Facts checked against Magnetrol and AMETEK company information, October 2026.

FAQ

Questions about the Magnetrol 004-5867-043 TG1 1 Inch Class 150 316 SS

Answers from our engineering team on installation, compatibility and integration.

01What is Magnetrol 004-5867-043?
It is the Thermatel TG1 thread-on mounting flange for 1 inch, 150 lbs raised face connections, made of 316/316L stainless steel, per manual BE 54-605.
02Why is its number out of sequence with 004-5867-001 to 004-5867-005?
The manual uses 001 to 005 for 1 1/2 to 6 inch 150 lbs stainless flanges and gives the 1 inch size its own number, 043, so the number should always be quoted in full.
03Does the flange fit a TML low flow body sensor?
No. The thread-on flanges are for sensors with 3/4 inch NPT male connection; the TML low flow body has 1/4 or 1/2 inch female connections.
04What is the sensor diameter that goes through the 1 inch flange?
The standard TMA to TMD sensors are 22.9 mm (0.90 inch) in diameter, the TMH is 21.9 mm and the TMM mini sensor is 16 mm.
05Can Seven Star LLC quote 004-5867-043?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location.