Brand: ABB
ABB Endura AZ20 Combustion Gas Oxygen Analyzer
Description
Overview
The ABB Endura AZ20 oxygen analyzer is an in-situ combustion instrument that measures O2 directly in the flue gas with a heated zirconium oxide cell mounted at the tip of the probe. Because no sample is extracted, the measurement avoids sample transport delay and sample system maintenance.
The AZ20 is part of ABB’s Endura combustion analyzer family and consists of a probe with an integral or remote transmitter. It is used for combustion trim control, efficiency monitoring and emissions-related O2 measurement on boilers, furnaces and fired heaters.
Key Features
- In-situ zirconia measurement, 0.01 to 100% O2 display range
- 316L stainless steel probe for process temperatures up to 800 °C
- Probe insertion lengths from 0.5 m to 4.0 m
- AutoCal option with built-in solenoid valves and test-gas pressure switches
- 4 to 20 mA output with HART 5.7, optional second isolated output
- Two relay outputs and NAMUR-style diagnostics
Technical Specifications
| Parameter | Value |
|---|---|
| Order code | AZ20 (configured code: probe length, flange, transmitter type, AutoCal, outputs) |
| Measurement principle | In-situ heated zirconium oxide cell |
| Range | 0.01 to 100% O2 |
| Process temperature | -20 to 800 °C (-4 to 1472 °F) |
| Probe insertion lengths | 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0 m |
| Probe material | 316L stainless steel |
| Process connections | ANSI B16.5 150 lb 2, 2.5, 3, 4 in; DIN 65, 80, 100 mm; JIS 5K; ABB standard flange |
| Transmitter | Integral (head-mounted) or remote |
| Analog output | 1 isolated 4 to 20 mA with HART 5.7; optional second isolated 0 to 20 mA |
| Relay outputs | 2, normally closed, 5 A at 230 V AC or 30 V DC (non-inductive) |
| Digital I/O | 2 optional, configurable as input or output |
| AutoCal | Isolated solenoid valve control 24 V at 2 W per valve; pressure-switch inputs |
| Probe heater supply | 100 to 240 V AC ±10%, 50/60 Hz via transmitter |
| System accuracy | Better than ±0.75% of reading or 0.05% O2, whichever is greater |
| Test gas response | Dead time 3 s; T90 under 10 s |
| Drift | Under ±1% of maximum O2 range per month without calibration |
| Ambient temperature | Transmitter -20 to 55 °C; probe head -20 to 70 °C |
| Ingress protection | IP66 / NEMA 4X for probe and transmitter enclosures |
| Power consumption | Electronics under 10 W; probe heater under 100 W |
| Process pressure | Withstands ±35 kPa; pressure compensation needed above 5 kPa |
| Remote transmitter cable | ABB 16-core probe cable, maximum 100 m |
| Reference air | 0.3 to 0.5 l/min; 1 bar (15 psi) regulated supply |
| Test gas flow | 2.2 l/min at 1 bar (15 psi) |
| Menu languages | English, German, French, Spanish, Italian |
Applications
- Combustion trim (air/fuel ratio) control on utility and industrial boilers
- O2 monitoring on refinery and petrochemical fired heaters and furnaces
- Efficiency monitoring on kilns and incinerators
- Oxygen measurement in flue gas for emissions reporting in power and desalination plants
ABB Endura AZ20 Ordering Code and Options
The AZ20 order code has a transmitter block and a probe block after the AZ20/ prefix. The first transmitter digit selects the output set: 1 for the standard transmitter, 2 for standard plus a second analog output, and 3 for standard plus two digital inputs/outputs. The next digits choose the cable entry (M20 or NPT) and the system type: integral, remote, or remote in a stainless steel housing.
In the probe block, the automatic calibration digit has four working choices: with or without AutoCal, each with or without built-in flow restrictors. Restrictors let the probe run from a fixed 1 bar supply without external flowmeters. The insertion length digit runs from 1 (0.5 m) to 8 (4.0 m) in 0.5 m steps. The flange character covers the ABB standard flange, DIN 65/80/100, ANSI 2, 2.5, 3 and 4 in, and JIS 65/80/100. The thermocouple is type K, and the cell option is either the standard cell or the large-surface-area filter for dusty gas.
Remaining positions set the probe cable length for remote systems (5, 10, 25, 50, 75 or 100 m), cable type, certification, menu language, and special features such as a corrosion-resistant PFA coating for process temperatures below 250 °C.
ABB Endura AZ20 Installation and Wiring Notes
The probe may be mounted at any angle from horizontal to vertically downward; ABB notes that horizontal probes longer than 2.0 m may need support. Reference air and test gas must be clean, dry and oil-free, passed through a 5 micron oil-coalescing filter-regulator from a supply of no more than 10 bar. Where no instrument air is available, ABB offers a reference air pump. On remote systems the cable screens are connected only at terminal 3 in the remote terminal housing and must not be earthed anywhere else. The mains input is protected by a 1.0 A type F fuse.
Why Seven Star LLC
Seven Star LLC supplies ABB Endura oxygen analyzers, probes and spares across Oman and the GCC. Before quoting, we confirm the complete order code, including probe insertion length, flange, transmitter type and AutoCal option, against the duct geometry and process conditions of the installation.
Request a Quote for ABB Endura AZ20 Combustion Gas Oxygen Analyzer
Send the AZ20 order code or nameplate data, quantity, flue gas temperature, duct or stack dimensions, required probe length and flange, and whether AutoCal and HART are needed through our Inquiry Form. We will confirm the configuration and respond with a formal quotation.
Related Products
- Southland Sensing OMD-625 Oxygen Analyzer
- AMETEK-930 H2S in Sulfur Pit Analyzer
- MSA Chillgard 5000 Refrigerant Monitor
- ProTech™ 1000 Z2 Tape-Based H2S / Total Sulfur Analyzer
- BARTEC Benke Vapor Pressure Process Analyzer RVP-4
- Servomex SERVOPRO 4900 Multigas Analyzer
How the ABB Endura AZ20 oxygen analyzer works
A heated zirconium oxide cell sits at the tip of the probe inside the flue gas. The cell produces a signal that depends on the oxygen content. The transmitter converts the signal into a 4 to 20 mA output.
Where the ABB Endura AZ20 oxygen analyzer is used
- Boilers
- Furnaces
- Fired heaters
- Combustion trim control
- Flue gas O2 measurement
Selection checklist for the ABB Endura AZ20 oxygen analyzer
- Probe insertion length
- Flange type
- Transmitter type
- AutoCal option
- Output needs
- Relay needs
- Process temperature
- Test gas supply
Installation, commissioning and maintenance notes for the ABB Endura AZ20 oxygen analyzer
Mount the probe on its flange in the flue and connect the transmitter. Connect the test gas lines if the AutoCal option is fitted. Check the calibration and the probe at regular intervals.
Requesting a quotation for the ABB Endura AZ20 oxygen analyzer
Please send the probe length, the flange and the transmitter type. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.
AZ20 analyzer type
It is an in-situ combustion oxygen analyzer.
AZ20 maker
It is made by ABB.
AZ20 family
It is part of the Endura combustion analyzer family.
AZ20 direct measurement
It measures O2 directly in the flue gas.
AZ20 sensing cell
It uses a heated zirconium oxide cell.
AZ20 cell position
The cell is mounted at the tip of the probe.
AZ20 no sample
No sample is extracted.
AZ20 sample delay
The measurement avoids sample transport delay.
AZ20 sample system
It avoids sample system maintenance.
AZ20 construction
It consists of a probe with a transmitter.
AZ20 transmitter
The transmitter is integral or remote.
AZ20 range
The display range is 0.01 to 100% O2.
AZ20 probe material
The probe is 316L stainless steel.
AZ20 process temperature
Process temperature runs up to 800 degrees C.
AZ20 insertion length
Insertion lengths run from 0.5 m to 4.0 m.
AZ20 length steps
Lengths come in steps of 0.5 m.
AZ20 AutoCal
An AutoCal option has built-in solenoid valves.
AZ20 test gas switches
AutoCal also has test-gas pressure switches.
AZ20 analog output
It has a 4 to 20 mA output with HART.
AZ20 second output
An optional second isolated output is available.
AZ20 relay outputs
It has two relay outputs.
AZ20 digital I/O
Two optional digital I/O points can be input or output.
AZ20 heater supply
The probe heater supply is 100 to 240 V AC.
AZ20 flanges
Several flange sizes and standards are available.
AZ20 duty
It is used for combustion trim control and emissions-related O2 measurement.
Analyzer records for the ABB Endura AZ20 oxygen analyzer
Record the calibration date, the O2 reading and the date of each check.
Choosing the right ABB Endura AZ20 oxygen analyzer probe length
Choose the insertion length from the wall thickness and the flue width.
Datasheets & Documents
- Datasheet ABB Endura AZ20 Combustion Gas Oxygen Analyzer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB, formed in 1988 and headquartered in Zurich, covers an unusually long stretch of a plant's equipment list, from the flowmeter and analyzer in the field to the drive, breaker and protection relay in the electrical room.
Seven Star LLC is an independent supplier serving Oman and the GCC. Our ABB listing concentrates on measurement and analytics: ABB flowmeters, liquid analysis sensors and systems, level and pressure instruments. It also includes valve actuators, low voltage circuit breakers, ABB drives, soft starters and protection relays.
ABB product families on this page
Flow measurement includes ABB electromagnetic, Coriolis, vortex and swirl meters, sold under names such as ProcessMaster, AquaMaster, CoriolisMaster and SwirlMaster. Liquid analysis covers pH, conductivity and dissolved oxygen sensors with their transmitters. SensyTemp TSP sensors handle temperature. On the electrical side the listing has ACS355 machinery drives, the ACS550 general purpose drive, the ACQ580 for water and wastewater and the ACS880-01 industrial drive, with fieldbus adapters such as the FPBA-01 for PROFIBUS DP. Protection and switching products include SACE Tmax XT molded case breakers, SACE Emax 2 air circuit breakers, PSR soft starters and the REM615 and RET615 relays.
Where ABB instruments and drives are used
Water and wastewater plants use the electromagnetic flowmeters, analyzers and ACQ580 drives together. Oil and gas, power and chemical plants specify the Coriolis and vortex meters, pressure and level transmitters and the 615 series relays for motor and transformer feeders. The drives run pumps, fans, conveyors and compressors in almost every industry.
Ordering ABB parts: what we need
For drives send the full type code from the rating label, for example ACS355-03E-05A6-4, plus the serial number if it is a replacement. For instruments send the complete order code, measuring span, process connection, wetted materials, output or protocol and the hazardous area approval. For breakers give frame size, rated current, breaking capacity, number of poles, trip unit and fixed or withdrawable version.
Related products
Frequently Asked Questions
It measures oxygen (O2) directly in flue and exhaust gas with a zirconium oxide cell mounted at the probe tip, over a range of 0.01 to 100% O2.
T90 response is under 10 seconds with an initial dead time of 3 seconds, which allows fast combustion trimming.
The robust probe operates at process temperatures up to 800 C (1472 F), with probe lengths up to 4.0 m (13.1 ft) for large ducts.
Yes. The integrated AutoCal system provides fully automatic calibration with two solenoid valve outputs and two test-gas detection inputs, eliminating the need for an external calibration panel.
A galvanically isolated 4-20 mA analog output with HART communication, plus two relay outputs rated 5 A at 230 VAC or 30 VDC.

Reviews
There are no reviews yet.