Legrand 420719 DPX3 250 Magnetic MCCB 3P 160 A 36 kA
Description
420719: Legrand DPX3 250 magnetic-only MCCB, 160 A, 36 kA, 3P
The Legrand 420719 is a DPX3 250 moulded-case circuit breaker in the magnetic-only version: three poles, 160 A rated current, 36 kA breaking capacity at 400 V and an adjustable magnetic trip from 800 to 1600 A. It has no thermal overload release, which is deliberate: the breaker supplies short-circuit protection, isolation and manual breaking for a motor circuit, while overload protection is left to a separate thermal relay. Seven Star LLC supplies 420719 in Oman and the GCC as an independent supplier in Muscat.
The catalogue describes the device as suitable for three-phase motors and notes cage terminals taking flexible cable up to 95 mm² (120 mm² with an accessory), IP30 protection, wing-knob operation and fixed mounting for plate or DIN rail in XL3 enclosures.
Decoding the description of 420719
| Element | Value | Meaning |
|---|---|---|
| DPX3 250 | Frame size | Legrand moulded-case frame for 100 to 250 A |
| Only mag | Trip unit | Magnetic short-circuit release only; no overload element |
| 3P 160 A | Poles and rating | Three poles with 160 A rated current |
| 36 kA | Breaking capacity | Icu at 400 V; the higher 70 kA series is a separate reference range |
| 800–1600 A | Magnetic setting | Adjustable 5 to 10 x In |
| Ref. 420719 | Catalogue number | Reference to quote |
Technical specifications for 420719
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Legrand / 420719 (DPX3 250 magnetic only, 3P, 160 A, 36 kA) |
| Type of protection | Magnetic only; no thermal overload release |
| Poles / rated current Iu | 3 / 160 A |
| Magnetic trip setting | Adjustable 5 to 10 x In, that is 800 to 1600 A |
| Rated voltage | 220–690 V AC (Ue 690 V, Ui 800 V, Uimp 8 kV) |
| Breaking capacity Icu (IEC 60947-2) | 36 kA at 380/415 V; 60 kA at 220/240 V; 30 kA at 440/460 V; 25 kA at 480/500 V; 20 kA at 600 V; 16 kA at 690 V; Ics 100 % of Icu |
| Making capacity Icm | 75.6 kA at 415 V |
| Utilisation category / isolation | A / suitable for isolation |
| Endurance | Mechanical 20,000 cycles; electrical 8,000 at In and 10,000 at 0.5 In |
| Dimensions 3P / weight | 105 x 165 x 100 mm / about 2.0 kg |
| Protection | IP30, fixed built-in version, wing-knob control, front connection with screw terminals |
| Operating temperature | -25 to 70 °C; tropical climate execution per data sheet |
| Mounting | On plate or DIN rail; supplied with fixing screws, connection plates and phase barriers |
| Accessories | Shunt and undervoltage releases, auxiliary and fault contacts, rotary handles, motor operators, plug-in base |
How 420719 protects a motor feeder
A motor draws a starting current several times its rated value, and a thermal-magnetic breaker sized for overload would trip on starting. The magnetic-only breaker avoids the conflict: it never trips on a normal start but cuts any short circuit above the setting you choose. The setting range of 420719 runs from 5 to 10 times 160 A, so the installer can place the threshold above the motor starting peak and below the minimum short-circuit current at the end of the cable.
Overload protection then comes from a thermal overload relay in a contactor starter, and the contactor performs the daily switching. The breaker is the back-up that interrupts a fault, provides isolation for maintenance and can be locked open. The data sheet states that the range complies with IEC 60947-2 and is suitable for isolation, and lists utilisation category A.
Where 420719 fits and related parts
Typical use is a motor control centre feeder: breaker, contactor and thermal relay in series. In the same frame the magnetic-only range covers 100 A (420718), 160 A (420719), 200 A (420720) and 250 A (420721) in 36 kA, with a 70 kA series above them. If a thermal element is needed in the breaker, the thermal-magnetic DPX3 250 such as 420207 should be used. The data sheet lists accessories including shunt and undervoltage releases, auxiliary and fault signalling contacts, direct and variable-depth rotary handles, motor operators and plug-in bases.
Selection checklist for 420719
- Application: motor or other load where overload protection is provided separately.
- Rated current: 160 A, with a motor starter rated for the motor current.
- Magnetic setting: choose above starting peak and below the minimum fault current.
- Fault level: 36 kA at 380/415 V; confirm the board prospective current, and use the 70 kA series if higher.
- Voltage: up to 690 V AC; breaking capacity falls at higher voltages as listed.
- Accessories: releases, handles, motor operator and terminal kits as required.
Installation, setting and maintenance of 420719
Mount the breaker on a plate or DIN rail with the supplied screws, fit the connection plates for bars or cable lugs, and install the phase barriers. Observe the data-sheet advice on the distance to the first conductor fixing point, because short-circuit forces act on the busbars. Set the magnetic dial after a coordination check, and seal or lock the cover if the setting must not be changed. Record 420719 and the setting in the board file. Operate the handle at planned shutdowns, inspect terminals for heat discolouration and replace the breaker if it has cleared a high-energy fault.
Typical applications in Oman and the GCC
Pump stations, compressors, desalination plant auxiliaries and fan banks in Oman and the GCC rely on motor feeders of this size. In outdoor and rooftop enclosures the ambient temperature may approach the top of the -25 to 70 °C range, so check the cabinet temperature and ventilation. Dust and coastal humidity make a sealed enclosure with regular terminal inspection advisable.
Information to send with an RFQ for 420719
- Reference 420719 and the quantity, including spares for panel maintenance.
- Rated current (160 A), trip type (magnetic only) and breaking capacity (36 kA or 70 kA).
- Motor power and starting method, and the starter or overload relay used.
- Accessories needed, such as rotary handle, shunt trip or motor operator.
- Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
- Any documents you need with the quotation, such as a technical data sheet or a compliance statement.
Documents and quotation
The Legrand technical data sheet that covers 420719 is attached on this page. It gives the range table, dimensions, curves and accessories, so check its notes against your design before you order.
To request a quotation, send reference 420719, the quantity and your delivery location. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer; we will confirm availability and lead time for your order.
Other Models in the Legrand Dpx3 250 Mo Range
Seven Star LLC supplies models from the Legrand Dpx3 250 Mo range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Legrand 420719 DPX3 250 Magnetic MCCB 3P 160 A 36 kA | Circuit Breakers | You are viewing this model |
| Legrand 420720 DPX3 250 Magnetic MCCB 3P 200 A 36 kA | Circuit Breakers | View details |
Datasheets & Documents
- Datasheet Legrand 420719 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Legrand is a French maker of electrical and digital building infrastructure, headquartered in Limoges. Its roots lie in a nineteenth-century porcelain workshop in Limoges, and it grew into one of the largest makers of wiring devices, circuit protection, cable management and data centre products. Legrand is listed on Euronext Paris and sells under brands including Legrand, Bticino and Cablofil.
Seven Star LLC, an independent supplier in Muscat, lists Legrand circuit breakers for electrical contractors and panel builders in Oman and the GCC, at present a DX3 4-pole miniature circuit breaker rated C32.
Legrand company profile
| Headquarters | Limoges, France |
|---|---|
| Listing | Euronext Paris |
| Brands | Legrand, Bticino, Cablofil, Zucchini |
| Product families | DX3 miniature circuit breakers and RCDs, wiring devices, cable trays, busbar trunking, UPS |
Legrand DX3 circuit breakers
DX3 is the Legrand family of modular protection devices for DIN rail mounting. The item on our site is a 4-pole MCB with a C tripping curve and a 32 A rated current. Three things besides the pole count define a breaker of this kind: the curve, the rated current and the breaking capacity printed on the front. Legrand catalogs DX3 breakers in 6000 A and 10000 A versions under separate references.
Ordering Legrand breakers: what we need
Send the Legrand catalog number printed on the device, a six-digit reference, where it is legible. Otherwise give the number of poles, the curve, the rated current, the breaking capacity and the voltage. Mention any auxiliary contact or residual current add-on module fitted beside the breaker, and the board type.
Facts checked against Legrand's published corporate information, October 2026.
Browse Legrand products by category: Circuit Breaker.
FAQ
Questions about the Legrand 420719 DPX3 250 Magnetic MCCB 3P 160 A 36 kA
Answers from our engineering team on installation, compatibility and integration.
01What is 420719?
It is a Legrand DPX3 250 magnetic-only moulded-case circuit breaker, three poles, 160 A, 36 kA breaking capacity at 400 V, with an adjustable magnetic trip of 800 to 1600 A.
02Does 420719 protect against overload?
No. A magnetic-only breaker has no thermal element. Overload protection must come from a separate thermal relay or motor protection device in the starter.
03What is the adjustment range of 420719?
The magnetic trip is adjustable from 800 to 1600 A, which is 5 to 10 times the 160 A rated current, so it can be set above motor starting current.
04What breaking capacity does 420719 have at other voltages?
Under IEC 60947-2 the data sheet lists 36 kA at 380/415 V, 30 kA at 440/460 V, 25 kA at 500 V, 20 kA at 600 V and 16 kA at 690 V, with Ics at 100 % of Icu.
05Can 420719 be mounted on a DIN rail?
Yes. The catalogue lists fixed mounting on plate or DIN rail, with front screw connection and a wing-knob control, and the data sheet describes the mounting options.