- Automation & ControlView all 2,467 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Motor Soft Starters
- Encoders
- Safety Switches & Guard Locking
- HMI Displays
- Pneumatic Cylinders
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Siemens
Siemens 3RH2911-1HA22 Front Auxiliary Switch Block 2NO+2NC
Description
3RH2911-1HA22 front auxiliary switch block, 2 NO + 2 NC
The Siemens 3RH2911-1HA22 is a snap-on front auxiliary switch block from the SIRIUS 3RH29 range. Siemens describes it as: auxiliary switch, on the front, 2 NO + 2 NC, .1/.2, .1/.2, .3/.4, .3/.4, current path: 1 NC, 1 NC, 1 NO, 1 NO, screw terminal, for contactors 3RT2 and contactor relays 3RH2. It adds two normally open and two normally closed contacts to a contactor or contactor relay, so one device can drive extra interlocks, status signals and feedback circuits without a separate relay. Seven Star LLC supplies the 3RH2911-1HA22 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.
The datasheet marks the contacts as .1/.2, .1/.2, .3/.4 and .3/.4: two NC contacts (terminals 1-2) and two NO contacts (terminals 3-4). Suitability for use is stated as for 3RT2.1, 3RT2.2, 3RT2.3, 3RT2.4, 3RH2. In plain terms it fits the front of S00, S0 and S2 contactors in the 3RT2 range as well as 3RH2 contactor relays.
3RH2911-1HA22 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Siemens / 3RH2911-1HA22 |
| Product family | SIRIUS 3RH29 auxiliary switch |
| Design | Snaps onto the front of the contactor |
| Contacts | 2 NO + 2 NC, instantaneous |
| Suitable for | for 3RT2.1, 3RT2.2, 3RT2.3, 3RT2.4, 3RH2 |
| Contact current AC-12 (maximum) | 10 A |
| Contact current AC-15 at 230 V / 400 V | 6 A / 3 A |
| Contact current AC-14 at 250 V | 6 A |
| Contact current DC-12 at 24 V / 220 V | 10 A / 1 A |
| Insulation voltage (pollution degree 3) | 690 V |
| Surge voltage resistance | 6 kV |
| Mechanical life (typical) | 10,000,000 operating cycles |
| Electrical endurance, AC-15 at 230 V (typical) | 200,000 operating cycles |
| Front protection class | IP20 |
| Dimensions (H x W x D) | 37.5 mm x 36 mm x 43.7 mm |
| Net weight | 54.69 g |
How the 3RH2911-1HA22 extends a contactor
A contactor has only a few built-in auxiliary contacts, and these are quickly used by the self-holding circuit and the running signal. The 3RH2911-1HA22 adds a block of four contacts that move together with the main contacts, so every time the contactor closes, the two NO contacts close and the two NC contacts open. The block is mounted on the front of the base device by snapping it into place; no tools are needed for the mechanical fit, and screw terminals take the wiring.
The contacts are rated 6 A at 230 V and 3 A at 400 V in AC-15 duty, which is the category used for inductive loads such as other contactor coils, and 10 A at 24 V in DC-12 duty for resistive and PLC-type loads. At higher DC voltages the permissible current drops (for example 1 A at 220 V), so check the DC data before switching DC solenoids or brakes.
Where the 3RH2911-1HA22 fits: contactors and relays
The block fits the front of 3RT2 power contactors and 3RH2 contactor relays, including the S00 contactors 3RT2015-1AP01, 3RT2016-1AP01, 3RT2017-1AP01 and 3RT2018-1AP01 and the S0 contactors 3RT2023-1AP00 to 3RT2028-1AP00, and the relays 3RH2122-1AP00, 3RH2131-1AP00 and 3RH2140-1AP00. Typical uses are interlocking reversing contactors, giving a feedback signal to a PLC or a protection relay, and extra start permissives in sequential control.
Selecting the 3RH2911-1HA22: ordering checklist
- Count the number of NO and NC contacts needed in addition to those already built into the contactor; this block adds 2 NO + 2 NC.
- Check that the base device is among those listed as suitable (3RT2.1, 3RT2.2, 3RT2.3, 3RT2.4 or 3RH2).
- Check that the loads fit the contact ratings: 6 A at 230 V AC-15 and 10 A at 24 V DC-12.
- For PLC inputs, consider contact reliability and the lower currents involved; use a block rated for small signals if needed.
- Check that the extra block fits within the panel depth, since it adds to the height of the stack.
Installing and maintaining the 3RH2911-1HA22
The block measures 37.5 mm high, 36 mm wide and 43.7 mm deep and weighs 54.69 g. It is snapped onto the front of the contactor, so the contactor should be mounted and wired first, and the block fitted afterwards. Wire the contacts with screw terminals and verify each contact with a multimeter. A mechanical life of 10,000,000 operating cycles and an electrical endurance of 200,000 cycles at AC-15 and 230 V are stated; if the contacts switch heavier loads than their rating, replace the block sooner. Keep a spare block with the contactor spares, as the part is small and cheap to hold.
Typical applications of the 3RH2911-1HA22 in Oman and the GCC
In Oman and the GCC, front auxiliary blocks are used in pump and fan starters, motor control centres and process skids when a contactor needs more contacts for permissives, trip circuits and status feedback to the DCS or PLC. They are also a common retrofit item when a panel is modified: instead of adding a new relay, the technician snaps a block onto an existing contactor. In dusty and hot sites the block is protected inside the panel, so IP20 front protection is adequate, as for the contactor itself.
Information to send with an RFQ for the 3RH2911-1HA22
- The full part number 3RH2911-1HA22 as printed on the device or in the bill of materials
- Quantity and delivery location in Oman or the GCC
- The contactor or relay type the block will be fitted to
- Loads to be switched, with voltage and AC or DC
Documents and quotation
A copy of the Siemens datasheet for the 3RH2911-1HA22 is attached on this page, so you can check ratings, dimensions and connection data before ordering. Seven Star LLC quotes against the exact part number, because neighbouring variants differ in coil voltage, range or contact arrangement and are not interchangeable without checking.
Send the part number 3RH2911-1HA22, the quantity and the delivery point in Oman or the GCC through the RFQ form, and we will reply with availability and lead time. Seven Star LLC is an independent supplier based in Muscat and is not affiliated with the manufacturer.
Other Models in the Siemens Sirius 3rh2 Range
Seven Star LLC supplies models from the Siemens Sirius 3rh2 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Siemens 3RH2122-1AP00 SIRIUS Contactor Relay 2 NO + 2 NC | Contactors & Overload Relays | View details |
| Siemens 3RH2131-1AP00 SIRIUS Contactor Relay 3 NO + 1 NC | Contactors & Overload Relays | View details |
| Siemens 3RH2140-1AP00 SIRIUS Contactor Relay 4 NO | Contactors & Overload Relays | View details |
| Siemens 3RH2911-1HA22 Front Auxiliary Switch Block 2NO+2NC | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet Siemens 3RH2911-1HA22 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Siemens is the German technology group whose industrial products include SIMATIC controllers and HMIs, SINAMICS drives, SIRIUS and SENTRON switching and protection devices, SIPROTEC protection relays, SITRANS process instruments, SCALANCE networks and process analysers. It was founded in Berlin on 12 October 1847 by Werner von Siemens and the precision mechanic Johann Georg Halske as Telegraphen-Bauanstalt von Siemens & Halske, to build Siemens's newly designed pointer telegraph. Siemens AG is headquartered in Munich and listed on the Frankfurt Stock Exchange; its energy business was spun off as Siemens Energy in 2020.
Siemens company profile
| Founded | 12 October 1847, Berlin, Germany, as Telegraphen-Bauanstalt von Siemens & Halske, with 10 employees |
|---|---|
| Founders | Werner von Siemens (1816–1892) and Johann Georg Halske (1814–1890) |
| First product | The pointer telegraph designed by Werner von Siemens |
| Headquarters | Munich, Germany (Siemens AG) |
| Ownership | Public company listed in Frankfurt; Siemens Energy (2020) and Siemens Healthineers are separately listed companies |
| Businesses acquired that appear in our range | Moore Products (bought in 2000; APACS and QUADLOG control systems), Applied Automation (Maxum process gas chromatographs); small industrial gas turbines such as the SGT-300 came with Alstom's industrial turbine business in 2003 |
| Product families | SIMATIC S7 PLCs, ET 200 distributed I/O and HMI panels, TIA Portal software, SINAMICS drives, SIMOTICS motors, SIRIUS and SENTRON low voltage devices, SIVACON switchboards, SIPROTEC relays, SITRANS instruments, SCALANCE network components, building technology valves and sensors |
Milestones
- 1847: Siemens & Halske starts work in Berlin with 10 employees.
- 1848: The company wins the contract for Europe's first long-distance telegraph line, Berlin to Frankfurt am Main.
- 1856: 330 employees, two-thirds of them working on telegraph networks in Russia.
- 1866: Werner von Siemens describes the dynamo-electric principle, the basis of the electric generator.
- 1958 onwards: The SIMATIC name is used for Siemens industrial automation; S7 PLCs follow in the 1990s and S7-1500 in 2012.
- 2020: Siemens Energy is spun off and listed separately.
Choosing Siemens automation products
A Siemens order number (MLFB) identifies the exact product: 6ES7 is SIMATIC automation, 6AV is HMI, 6GK is industrial communication, 6SL is SINAMICS drives, 3R is SIRIUS control and 5SY is SENTRON miniature circuit breakers. For PLCs, S7-1200 is the compact controller for small machines, S7-1500 is the current mid-to-high range controller, and S7-300 and S7-400 are older platforms still running in many plants; S7-300 is being phased out, so spares and migration to S7-1500 are common requests. When replacing a CPU or module, the full order number including the version digits matters, because firmware and hardware versions affect compatibility with the existing project.
Where Siemens products are used
In Oman and the GCC, Siemens automation runs in oil and gas, power and desalination plants, water networks, cement and process industries. Maxum gas chromatographs analyse gas composition in gas plants and refineries, SIPROTEC relays protect substations, SGT-300 turbines drive generators and compressors, and Siemens building valves are used in HVAC systems.
Siemens products we list
| Family | Examples |
|---|---|
| SIMATIC controllers and I/O | S7-1500, CPU 1515-2 PN, S7-1200, CPU 1214C, S7-300, S7-400H CPU 412-5H, ET 200SP, IM 153-2 |
| HMI and networking | KTP700 Basic, TP700 Comfort, TP1200 Comfort, SCALANCE XC208, SCALANCE WAM766, PROFIBUS OLM |
| Drives, motors and power distribution | SINAMICS G120C, SINAMICS G120X, 1LA7 motor, SIVACON S8, SIPROTEC 7SJ85, 5SY4510-7 MCB |
| Process instruments | SITRANS P320, MAG 5100W, SITRANS TH320, SITRANS TS500, SITRANS TR200 |
| Maxum II analyser spares | FID 302A detector, FPD II assembly, filament detector, Model 50 valve, SYSCON kit, air bath heater |
| APACS and QUADLOG spares | QLCCM24AAN, QLSAMBAN, QLSDM024DCCBN, 39SAMCAN, 16137-151 M-BUS cable |
| Building technology | VPI46 PICV, VPF44, QFM1660 sensor |
Ordering Siemens products: what we need
Send the full order number from the label (for example 6ES7214-1AG40-0XB0) and, for PLC and HMI parts, the hardware and firmware version (FS and V numbers). For Maxum II and APACS spares, send the Siemens part number such as 2021651-002. For drives, add the motor power and supply voltage.
Frequently requested Siemens models: Siemens IM 155-6 PN ST ET 200SP Interface Module 6ES7155-6AU02-0BN0, Siemens SGT-300 Industrial Gas Turbine.
Facts checked against Siemens's published history timeline, October 2026.
FAQ
Questions about the Siemens 3RH2911-1HA22 Front Auxiliary Switch Block
Answers from our engineering team on installation, compatibility and integration.
01What contacts does the 3RH2911-1HA22 add?
It adds two normally open and two normally closed instantaneous contacts, marked .1/.2, .1/.2, .3/.4 and .3/.4 on the datasheet. They move together with the main contacts of the base device.
02Which devices accept the 3RH2911-1HA22?
The datasheet lists suitability for 3RT2.1, 3RT2.2, 3RT2.3, 3RT2.4 contactors and 3RH2 contactor relays. It snaps onto the front of the device.
03What load ratings do the contacts of the 3RH2911-1HA22 have?
Contacts are rated 6A at 230 V AC-15 and 3A at 400 V AC-15, and 10 A at 24 V DC-12. Check the DC voltage curve for higher DC loads.
04How long does the 3RH2911-1HA22 last?
The datasheet states a typical mechanical life of 10 000 000 operating cycles and an electrical endurance of 200 000 cycles at AC-15 and 230 V. Heavier loads shorten this.
05How big is the 3RH2911-1HA22?
It measures 37.5 mm x 36 mm x 43.7 mm and weighs 54.69 g. It adds to the depth of the contactor stack when fitted to the front.


















Reviews
There are no reviews yet.