Brand:

Siemens 3RV2011-1CA10 SIRIUS Motor Protector Breaker 1.8-2.5 A

Description

3RV2011-1CA10 SIRIUS 3RV2 motor starter protector, 1.8 to 2.5 A, S00

The Siemens 3RV2011-1CA10 is a SIRIUS 3RV2 circuit breaker for motor protection in the S00 frame. Siemens describes it as: Circuit breaker size S00 for motor protection, CLASS 10 A-release 1.8 to 2.5 A N- release 33 A screw terminal Standard switching capacity. It combines a thermal overload release adjustable over 1.8 to 2.5 A with a magnetic short-circuit release that responds at 33 A, in a single DIN-rail device that also serves as a disconnector. Seven Star LLC supplies the 3RV2011-1CA10 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

With a range of 1.8 to 2.5 A it is the lowest setting range among the three breakers listed here and is meant for very small motors such as small pumps and dosing or instrument drives. The datasheet gives a motor power of 0.75 kW at 400 V in AC-3 for this device.

3RV2011-1CA10 technical specifications

Parameter Specification
Manufacturer / part number Siemens / 3RV2011-1CA10
Product family SIRIUS 3RV2 circuit breaker for motor protection
Frame size S00
Adjustable overload release 1.8 to 2.5 A
Rated continuous current 2.5 A
Trip class CLASS 10
Instantaneous short-circuit release 33 A
Motor power AC-3 at 230 V / 400 V / 500 V / 690 V 0.4 kW / 0.75 kW / 1.1 kW / 1.5 kW
Breaking capacity Icu at 240 V / 400 V / 500 V / 690 V 100 kA / 100 kA / 100 kA / 10 kA
Service breaking capacity Ics at 240 V / 400 V / 500 V / 690 V 100 kA / 100 kA / 100 kA / 10 kA
Phase failure detection Yes
Disconnector function Yes
Mechanical / electrical endurance 100,000 / 100,000 operating cycles
Ambient temperature, operation / storage -20 to +60 °C / -50 to +80 °C
Dimensions (H x W x D) 97 mm x 45 mm x 97 mm
Net weight 323.6 g
Main conductor, finely stranded with ferrule 0.5 to 2.5 mm²
UL full-load current at 480 V / hp at 460-480 V 2.5 A / 1 hp
ATEX certificate listed DMT 02 ATEX F 001
ATEX type of protection listed Ex II (2) GD
UL file number listed E47705 (NLRV, NLRV7), E156943 (NKJH, NKJH7)

How the 3RV2011-1CA10 protects the motor and the cable

A motor starter protector does two jobs at once. Its thermal release follows the motor current and trips when the load stays above the set value, here adjustable from 1.8 A to 2.5 A with trip CLASS 10. Its magnetic release reacts without delay to short circuits: for the 3RV2011-1CA10 the instantaneous release value is 33 A, which is fixed by the device and sits well above normal motor starting current. Phase-failure sensitivity is part of the thermal function, so the breaker also responds to an open phase.

Breaking capacity is stated as Icu 100 kA and Ics 100 kA at 400 V, falling to 10 kA and 10 kA at 690 V. Compare these values with the prospective short-circuit current at the panel. Because the breaker also works as a manual switch and disconnector, it replaces the combination of fuse, switch and overload relay in many small motor feeders, saving panel space and wiring time.

Where the 3RV2011-1CA10 fits: contactors and the upstream feeder

The 3RV2011-1CA10 sits upstream of a contactor to build a motor starter. The datasheet lists compatible contactor sizes of S00, S0, which in SIRIUS terms means contactors like 3RT2015-1AP01, 3RT2016-1AP01, 3RT2017-1AP01 and 3RT2018-1AP01 (S00). The breaker does not need a separate overload relay for motor protection, so the starter is a breaker plus contactor. When more than one motor shares a feeder, check that the upstream fuse or breaker is not larger than the value the datasheet allows. For an IT network the datasheet lists a gL/gG 25 A fuse at 400 V.

Selecting the 3RV2011-1CA10: ordering checklist

  • Pick the breaker whose range (1.8 to 2.5 A) contains the motor nameplate current, ideally in the middle of the range.
  • Check the instantaneous trip value (33 A) against the motor starting current.
  • Compare breaking capacity (100 kA at 400 V, 10 kA at 690 V) with the prospective short-circuit level.
  • Confirm the frame size: S00, with the contactor you plan to mount below it.
  • Decide whether front or side auxiliary or trip-signal blocks are needed; the device itself has no built-in auxiliary contacts.

Installing and maintaining the 3RV2011-1CA10

The 3RV2011-1CA10 is 97 mm high, 45 mm wide and 97 mm deep, weighs 323.6 g, and snaps onto a 35 mm DIN rail or is screwed to a plate. Observe the spacing for the voltage used because the datasheet gives distances to grounded and live parts, which grow at 690 V. Main terminals take 0.5 to 2.5 mm² finely stranded with ferrule. Use the front dial to set the current and keep a record of the setting. Operate the breaker occasionally to verify the mechanism, and after a short-circuit trip, inspect the downstream cable and replace the breaker if the manual instructs.

Typical applications of the 3RV2011-1CA10 in Oman and the GCC

In Oman and the GCC these breakers feed pump, fan and conveyor motors, dosing and instrument skids and small compressors in utility, oil and gas and water plants. Cabinets in the region run hot, and the datasheet rates the 3RV2011-1CA10 for -20 to +60 °C in operation, so check cabinet ventilation and any derating. The 3RV2011-1CA10 suits motors of about 0.75 kW at 400 V.

3RV2 motor starter protectors we can supply, compared

Part number Size Overload range Instantaneous trip Net weight
3RV2011-1CA10 (this product) S00 1.8 to 2.5 A 33 A 323.6 g
3RV2011-1JA10 S00 7 to 10 A 130 A 327.6 g
3RV2021-4AA10 S0 10 to 16 A 208 A 338.6 g

Information to send with an RFQ for the 3RV2011-1CA10

  • The full part number 3RV2011-1CA10 as printed on the nameplate or in the bill of materials
  • Quantity and delivery location in Oman or the GCC
  • Motor nameplate current (the 3RV2011-1CA10 covers 1.8 to 2.5 A)
  • Prospective short-circuit current at the panel and system voltage

Documents and quotation

A copy of the Siemens datasheet for the 3RV2011-1CA10 is attached on this page, so you can check ratings, dimensions and connection data before ordering. Seven Star LLC quotes against the exact part number, because neighbouring variants differ in coil voltage, range or contact arrangement and are not interchangeable without checking.

Send the part number 3RV2011-1CA10, the quantity and the delivery point in Oman or the GCC through the RFQ form, and we will reply with availability and lead time. Seven Star LLC is an independent supplier based in Muscat and is not affiliated with the manufacturer.

Other Models in the Siemens Sirius 3rv2 Range

Seven Star LLC supplies models from the Siemens Sirius 3rv2 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Siemens 3RV2011-1CA10 SIRIUS Motor Protector Breaker 1.8-2.5 AContactors & Overload RelaysYou are viewing this model
Siemens 3RV2011-1JA10 SIRIUS Motor Protector Breaker 7-10 AContactors & Overload RelaysView details
Siemens 3RV2021-4AA10 SIRIUS Motor Protector Breaker 10-16 AContactors & Overload RelaysView details
Datasheets & Documents
  • PDF Datasheet Siemens 3RV2011-1CA10 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Siemens is the German technology group whose industrial products include SIMATIC controllers and HMIs, SINAMICS drives, SIRIUS and SENTRON switching and protection devices, SIPROTEC protection relays, SITRANS process instruments, SCALANCE networks and process analysers. It was founded in Berlin on 12 October 1847 by Werner von Siemens and the precision mechanic Johann Georg Halske as Telegraphen-Bauanstalt von Siemens & Halske, to build Siemens's newly designed pointer telegraph. Siemens AG is headquartered in Munich and listed on the Frankfurt Stock Exchange; its energy business was spun off as Siemens Energy in 2020.

Siemens company profile

Founded 12 October 1847, Berlin, Germany, as Telegraphen-Bauanstalt von Siemens & Halske, with 10 employees
Founders Werner von Siemens (1816–1892) and Johann Georg Halske (1814–1890)
First product The pointer telegraph designed by Werner von Siemens
Headquarters Munich, Germany (Siemens AG)
Ownership Public company listed in Frankfurt; Siemens Energy (2020) and Siemens Healthineers are separately listed companies
Businesses acquired that appear in our range Moore Products (bought in 2000; APACS and QUADLOG control systems), Applied Automation (Maxum process gas chromatographs); small industrial gas turbines such as the SGT-300 came with Alstom's industrial turbine business in 2003
Product families SIMATIC S7 PLCs, ET 200 distributed I/O and HMI panels, TIA Portal software, SINAMICS drives, SIMOTICS motors, SIRIUS and SENTRON low voltage devices, SIVACON switchboards, SIPROTEC relays, SITRANS instruments, SCALANCE network components, building technology valves and sensors

Milestones

  • 1847: Siemens & Halske starts work in Berlin with 10 employees.
  • 1848: The company wins the contract for Europe's first long-distance telegraph line, Berlin to Frankfurt am Main.
  • 1856: 330 employees, two-thirds of them working on telegraph networks in Russia.
  • 1866: Werner von Siemens describes the dynamo-electric principle, the basis of the electric generator.
  • 1958 onwards: The SIMATIC name is used for Siemens industrial automation; S7 PLCs follow in the 1990s and S7-1500 in 2012.
  • 2020: Siemens Energy is spun off and listed separately.

Choosing Siemens automation products

A Siemens order number (MLFB) identifies the exact product: 6ES7 is SIMATIC automation, 6AV is HMI, 6GK is industrial communication, 6SL is SINAMICS drives, 3R is SIRIUS control and 5SY is SENTRON miniature circuit breakers. For PLCs, S7-1200 is the compact controller for small machines, S7-1500 is the current mid-to-high range controller, and S7-300 and S7-400 are older platforms still running in many plants; S7-300 is being phased out, so spares and migration to S7-1500 are common requests. When replacing a CPU or module, the full order number including the version digits matters, because firmware and hardware versions affect compatibility with the existing project.

Where Siemens products are used

In Oman and the GCC, Siemens automation runs in oil and gas, power and desalination plants, water networks, cement and process industries. Maxum gas chromatographs analyse gas composition in gas plants and refineries, SIPROTEC relays protect substations, SGT-300 turbines drive generators and compressors, and Siemens building valves are used in HVAC systems.

Siemens products we list

Family Examples
SIMATIC controllers and I/O S7-1500, CPU 1515-2 PN, S7-1200, CPU 1214C, S7-300, S7-400H CPU 412-5H, ET 200SP, IM 153-2
HMI and networking KTP700 Basic, TP700 Comfort, TP1200 Comfort, SCALANCE XC208, SCALANCE WAM766, PROFIBUS OLM
Drives, motors and power distribution SINAMICS G120C, SINAMICS G120X, 1LA7 motor, SIVACON S8, SIPROTEC 7SJ85, 5SY4510-7 MCB
Process instruments SITRANS P320, MAG 5100W, SITRANS TH320, SITRANS TS500, SITRANS TR200
Maxum II analyser spares FID 302A detector, FPD II assembly, filament detector, Model 50 valve, SYSCON kit, air bath heater
APACS and QUADLOG spares QLCCM24AAN, QLSAMBAN, QLSDM024DCCBN, 39SAMCAN, 16137-151 M-BUS cable
Building technology VPI46 PICV, VPF44, QFM1660 sensor

Ordering Siemens products: what we need

Send the full order number from the label (for example 6ES7214-1AG40-0XB0) and, for PLC and HMI parts, the hardware and firmware version (FS and V numbers). For Maxum II and APACS spares, send the Siemens part number such as 2021651-002. For drives, add the motor power and supply voltage.

Frequently requested Siemens models: Siemens IM 155-6 PN ST ET 200SP Interface Module 6ES7155-6AU02-0BN0, Siemens SGT-300 Industrial Gas Turbine.

Facts checked against Siemens's published history timeline, October 2026.

FAQ

Questions about the Siemens 3RV2011-1CA10 SIRIUS Motor Protector

Answers from our engineering team on installation, compatibility and integration.

01What current range can the 3RV2011-1CA10 be set to?
The thermal overload release is adjustable from 1.8 to 2.5 A. Set it to the nameplate current of the motor, and check the instantaneous trip of 33 A against starting current.
02What is the breaking capacity of the 3RV2011-1CA10?
The datasheet gives Icu of 100 kA and Ics of 100 kA at 400 V, and 10 kA and 10 kA at 690 V. Compare the figure for your voltage with the available short-circuit current.
03Does the 3RV2011-1CA10 replace an overload relay?
Yes, the breaker contains a thermal overload release with trip CLASS 10, together with the magnetic short-circuit release. Only a contactor is needed for a complete direct-on-line motor starter.
04Which contactors can be combined with the 3RV2011-1CA10?
The datasheet lists combinable contactor sizes of S00, S0. In practice this means SIRIUS S00 and S0 contactors such as 3RT2015-1AP01, 3RT2016-1AP01, 3RT2017-1AP01.
05What size is the 3RV2011-1CA10?
It is a S00 frame breaker measuring 97 mm x 45 mm x 97 mm with a net weight of 323.6 g. It snaps onto a 35 mm DIN rail.